Resumo: The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.
id UNSP_3bf94f6656ded6bf40c5a48ce04c1cba
oai_identifier_str oai:repositorio.unesp.br:11449/69031
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticalsNaproxenate-sensitive electrodePharmaceutical formulationsPotentiometryThe characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.Instituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SPInstituto de Química Universidade Estadual Paulista, CP 355, 14801-970 Araraquara-SPUniversidade Estadual Paulista (Unesp)Santini, Alberto O. [UNESP]Oliveira, Jose Eduardo de [UNESP]Pezza, Helena Redigolo [UNESP]Pezza, Leonardo [UNESP]2014-05-27T11:21:56Z2014-05-27T11:21:56Z2006-08-09info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article785-791application/pdfhttp://dx.doi.org/10.1590/S0103-50532006000400022Journal of the Brazilian Chemical Society, v. 17, n. 4, p. 785-791, 2006.0103-5053http://hdl.handle.net/11449/6903110.1590/S0103-50532006000400022S0103-50532006000400022WOS:0002396168000212-s2.0-337467546802-s2.0-33746754680.pdf9352141379363877319212509836112159789085918535240000-0003-0197-7369Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of the Brazilian Chemical Society1.4440,357info:eu-repo/semantics/openAccess2023-11-18T06:17:03Zoai:repositorio.unesp.br:11449/69031Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T18:05:22.171719Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
title A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
spellingShingle A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
Santini, Alberto O. [UNESP]
Naproxenate-sensitive electrode
Pharmaceutical formulations
Potentiometry
title_short A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
title_full A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
title_fullStr A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
title_full_unstemmed A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
title_sort A novel potentiometric naproxenate ion sensor immobilized in a graphite matrix for determination of naproxen in pharmaceuticals
author Santini, Alberto O. [UNESP]
author_facet Santini, Alberto O. [UNESP]
Oliveira, Jose Eduardo de [UNESP]
Pezza, Helena Redigolo [UNESP]
Pezza, Leonardo [UNESP]
author_role author
author2 Oliveira, Jose Eduardo de [UNESP]
Pezza, Helena Redigolo [UNESP]
Pezza, Leonardo [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Santini, Alberto O. [UNESP]
Oliveira, Jose Eduardo de [UNESP]
Pezza, Helena Redigolo [UNESP]
Pezza, Leonardo [UNESP]
dc.subject.por.fl_str_mv Naproxenate-sensitive electrode
Pharmaceutical formulations
Potentiometry
topic Naproxenate-sensitive electrode
Pharmaceutical formulations
Potentiometry
description The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.
publishDate 2006
dc.date.none.fl_str_mv 2006-08-09
2014-05-27T11:21:56Z
2014-05-27T11:21:56Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/S0103-50532006000400022
Journal of the Brazilian Chemical Society, v. 17, n. 4, p. 785-791, 2006.
0103-5053
http://hdl.handle.net/11449/69031
10.1590/S0103-50532006000400022
S0103-50532006000400022
WOS:000239616800021
2-s2.0-33746754680
2-s2.0-33746754680.pdf
9352141379363877
3192125098361121
5978908591853524
0000-0003-0197-7369
url http://dx.doi.org/10.1590/S0103-50532006000400022
http://hdl.handle.net/11449/69031
identifier_str_mv Journal of the Brazilian Chemical Society, v. 17, n. 4, p. 785-791, 2006.
0103-5053
10.1590/S0103-50532006000400022
S0103-50532006000400022
WOS:000239616800021
2-s2.0-33746754680
2-s2.0-33746754680.pdf
9352141379363877
3192125098361121
5978908591853524
0000-0003-0197-7369
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of the Brazilian Chemical Society
1.444
0,357
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 785-791
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128893220028416