Resumo: | Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 × 10 × 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. |
id |
UNSP_4f480a34d2d5bc693678c94e1f599755 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/231851 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfectionAcrylic resinsCross infectionDisinfectionFlexural strengthHardnessMicrowaveObjectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 × 10 × 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection.Department of Dental Materials and Prosthodontics São Paulo State University UNESP, São PauloFaculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903Department of Dental Materials and Prosthodontics São Paulo State University UNESP, São PauloFaculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903Universidade Estadual Paulista (UNESP)Ribeiro, Daniela Garcia [UNESP]Pavarina, Ana Cláudia [UNESP]Machado, Ana Lucia [UNESP]Giampaolo, Eunice Teresinha [UNESP]Vergani, Carlos Eduardo [UNESP]2022-04-29T08:47:48Z2022-04-29T08:47:48Z2008-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article833-840Quintessence International, v. 39, n. 10, p. 833-840, 2008.0033-6572http://hdl.handle.net/11449/2318512-s2.0-54449094716Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengQuintessence Internationalinfo:eu-repo/semantics/openAccess2024-09-27T14:57:34Zoai:repositorio.unesp.br:11449/231851Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-27T14:57:34Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
title |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
spellingShingle |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection Ribeiro, Daniela Garcia [UNESP] Acrylic resins Cross infection Disinfection Flexural strength Hardness Microwave |
title_short |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
title_full |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
title_fullStr |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
title_full_unstemmed |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
title_sort |
Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection |
author |
Ribeiro, Daniela Garcia [UNESP] |
author_facet |
Ribeiro, Daniela Garcia [UNESP] Pavarina, Ana Cláudia [UNESP] Machado, Ana Lucia [UNESP] Giampaolo, Eunice Teresinha [UNESP] Vergani, Carlos Eduardo [UNESP] |
author_role |
author |
author2 |
Pavarina, Ana Cláudia [UNESP] Machado, Ana Lucia [UNESP] Giampaolo, Eunice Teresinha [UNESP] Vergani, Carlos Eduardo [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Ribeiro, Daniela Garcia [UNESP] Pavarina, Ana Cláudia [UNESP] Machado, Ana Lucia [UNESP] Giampaolo, Eunice Teresinha [UNESP] Vergani, Carlos Eduardo [UNESP] |
dc.subject.por.fl_str_mv |
Acrylic resins Cross infection Disinfection Flexural strength Hardness Microwave |
topic |
Acrylic resins Cross infection Disinfection Flexural strength Hardness Microwave |
description |
Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 × 10 × 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-11-01 2022-04-29T08:47:48Z 2022-04-29T08:47:48Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Quintessence International, v. 39, n. 10, p. 833-840, 2008. 0033-6572 http://hdl.handle.net/11449/231851 2-s2.0-54449094716 |
identifier_str_mv |
Quintessence International, v. 39, n. 10, p. 833-840, 2008. 0033-6572 2-s2.0-54449094716 |
url |
http://hdl.handle.net/11449/231851 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Quintessence International |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
833-840 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1813546531959078912 |