Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1590/1982-0216201820412317 http://hdl.handle.net/11449/157772 |
Resumo: | ABSTRACTPurpose: to verify if the accuracy in the judgment of the ultrasound (US) images varies according to the experience of the judges and the sound class - alveolar liquids and coronal fricatives.Methods: ultrasound images related to the production of liquids and fricatives in the intervocalic context of the vowel /a/, produced by 20 typical adults, were judged by 15 experienced judges and 15 non-experienced judges. A previous analysis of the images was performed to establish the typical ultrasound pattern of the liquids and fricatives. The accuracy (% of correctness and errors) of the judgments performed by the judges was considered in the analysis. Factorial ANOVA statistical test was used, considering as factors the sound class and the experience of the judges.Results: the Factorial ANOVA showed a significant effect for the accuracy of the judgment only for the sound class, with no significance for the judges' experience or for the interaction between the experience of judges and the sound class. The liquids had a lower accuracy in the judgment, as compared to the fricatives, confirming their articulatory complexity, since they involve the production of two simultaneous gestures.Conclusion: the accuracy in the judgment of the US images did not vary according to the experience of judges, but it was dependent on the sound class. It should be noted, however, that all judges presented previous knowledge about the processes of speech production which may have favored image interpretation. |
id |
UNSP_592dfcf185733e0f17f6104a158d867e |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/157772 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judgesAnálise ultrassonográfica das líquidas alveolares e fricativas coronais: julgamento de juízes experientes e não experientesSpeechPhoneticUltrasonographyFalaFonéticaUltrassonografiaABSTRACTPurpose: to verify if the accuracy in the judgment of the ultrasound (US) images varies according to the experience of the judges and the sound class - alveolar liquids and coronal fricatives.Methods: ultrasound images related to the production of liquids and fricatives in the intervocalic context of the vowel /a/, produced by 20 typical adults, were judged by 15 experienced judges and 15 non-experienced judges. A previous analysis of the images was performed to establish the typical ultrasound pattern of the liquids and fricatives. The accuracy (% of correctness and errors) of the judgments performed by the judges was considered in the analysis. Factorial ANOVA statistical test was used, considering as factors the sound class and the experience of the judges.Results: the Factorial ANOVA showed a significant effect for the accuracy of the judgment only for the sound class, with no significance for the judges' experience or for the interaction between the experience of judges and the sound class. The liquids had a lower accuracy in the judgment, as compared to the fricatives, confirming their articulatory complexity, since they involve the production of two simultaneous gestures.Conclusion: the accuracy in the judgment of the US images did not vary according to the experience of judges, but it was dependent on the sound class. It should be noted, however, that all judges presented previous knowledge about the processes of speech production which may have favored image interpretation.RESUMOObjetivo: verificar se a acurácia no julgamento das imagens ultrassonográficas (US) varia em função da experiência dos juízes e da classe sonora - líquidas alveolares e fricativas coronais.Métodos: imagens ultrassonográficas relativas à produção das líquidas e fricativas no contexto intervocálico da vogal /a/, produzidas por 20 adultos típicos, foram julgadas por 15 juízes experientes e 15 inexperientes. Uma análise prévia das imagens foi feita para estabelecer o padrão ultrassonográfico típico das líquidas e fricativas. Considerou-se na análise a acurácia (% de acertos e erros) dos julgamentos feito pelos juízes. Utilizou-se o teste estatístico Anova Fatorial, considerando como fatores a classe sonora e a experiência dos juízes.Resultados: a ANOVA Fatorial mostrou um efeito significante para a acurácia do julgamento apenas para a classe sonora, não havendo significância quanto à experiência dos juízes nem quanto à interação entre experiência dos juízes e classe sonora. As líquidas tiveram uma menor acurácia no julgamento comparando às fricativas, confirmando sua complexidade articulatória, uma vez que envolve a produção de dois gestos simultâneos.Conclusão: a acurácia no julgamento das imagens US não variou em função da experiência dos juízes, mas foi dependente da classe sonora. Destaca-se, no entanto, que todos os juízes apresentavam conhecimento prévio sobre os processos de produção de fala o que pode ter favorecido a interpretação das imagens.Universidade Estadual Paulista Faculdade de Filosofia e CiênciasUniversidade Estadual Paulista Faculdade de Filosofia e CiênciasABRAMO Associação Brasileira de Motricidade OrofacialUniversidade Estadual Paulista (Unesp)Lima, Fernanda Leitão De Castro Nunes DeSilva, Cássio Eduardo Esperandino DaSilva, Lídia Maurício DaVassoler, Aline Mara De OliveiraFabbron, Eliana Maria GradimBerti, Larissa Cristina2018-11-12T17:26:52Z2018-11-12T17:26:52Z2018-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article422-431application/pdfhttp://dx.doi.org/10.1590/1982-0216201820412317Revista CEFAC. ABRAMO Associação Brasileira de Motricidade Orofacial, v. 20, n. 4, p. 422-431, 2018.1516-1846http://hdl.handle.net/11449/15777210.1590/1982-0216201820412317S1516-18462018000400422S1516-18462018000400422.pdf59988332402675270000-0001-5197-0347SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengRevista CEFACinfo:eu-repo/semantics/openAccess2023-10-25T06:11:33Zoai:repositorio.unesp.br:11449/157772Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:57:27.336055Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges Análise ultrassonográfica das líquidas alveolares e fricativas coronais: julgamento de juízes experientes e não experientes |
title |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
spellingShingle |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges Lima, Fernanda Leitão De Castro Nunes De Speech Phonetic Ultrasonography Fala Fonética Ultrassonografia |
title_short |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
title_full |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
title_fullStr |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
title_full_unstemmed |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
title_sort |
Ultrasonographic analysis of lateral liquids and coronal fricatives: judgment of experienced and non-experienced judges |
author |
Lima, Fernanda Leitão De Castro Nunes De |
author_facet |
Lima, Fernanda Leitão De Castro Nunes De Silva, Cássio Eduardo Esperandino Da Silva, Lídia Maurício Da Vassoler, Aline Mara De Oliveira Fabbron, Eliana Maria Gradim Berti, Larissa Cristina |
author_role |
author |
author2 |
Silva, Cássio Eduardo Esperandino Da Silva, Lídia Maurício Da Vassoler, Aline Mara De Oliveira Fabbron, Eliana Maria Gradim Berti, Larissa Cristina |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Lima, Fernanda Leitão De Castro Nunes De Silva, Cássio Eduardo Esperandino Da Silva, Lídia Maurício Da Vassoler, Aline Mara De Oliveira Fabbron, Eliana Maria Gradim Berti, Larissa Cristina |
dc.subject.por.fl_str_mv |
Speech Phonetic Ultrasonography Fala Fonética Ultrassonografia |
topic |
Speech Phonetic Ultrasonography Fala Fonética Ultrassonografia |
description |
ABSTRACTPurpose: to verify if the accuracy in the judgment of the ultrasound (US) images varies according to the experience of the judges and the sound class - alveolar liquids and coronal fricatives.Methods: ultrasound images related to the production of liquids and fricatives in the intervocalic context of the vowel /a/, produced by 20 typical adults, were judged by 15 experienced judges and 15 non-experienced judges. A previous analysis of the images was performed to establish the typical ultrasound pattern of the liquids and fricatives. The accuracy (% of correctness and errors) of the judgments performed by the judges was considered in the analysis. Factorial ANOVA statistical test was used, considering as factors the sound class and the experience of the judges.Results: the Factorial ANOVA showed a significant effect for the accuracy of the judgment only for the sound class, with no significance for the judges' experience or for the interaction between the experience of judges and the sound class. The liquids had a lower accuracy in the judgment, as compared to the fricatives, confirming their articulatory complexity, since they involve the production of two simultaneous gestures.Conclusion: the accuracy in the judgment of the US images did not vary according to the experience of judges, but it was dependent on the sound class. It should be noted, however, that all judges presented previous knowledge about the processes of speech production which may have favored image interpretation. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-11-12T17:26:52Z 2018-11-12T17:26:52Z 2018-08-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/1982-0216201820412317 Revista CEFAC. ABRAMO Associação Brasileira de Motricidade Orofacial, v. 20, n. 4, p. 422-431, 2018. 1516-1846 http://hdl.handle.net/11449/157772 10.1590/1982-0216201820412317 S1516-18462018000400422 S1516-18462018000400422.pdf 5998833240267527 0000-0001-5197-0347 |
url |
http://dx.doi.org/10.1590/1982-0216201820412317 http://hdl.handle.net/11449/157772 |
identifier_str_mv |
Revista CEFAC. ABRAMO Associação Brasileira de Motricidade Orofacial, v. 20, n. 4, p. 422-431, 2018. 1516-1846 10.1590/1982-0216201820412317 S1516-18462018000400422 S1516-18462018000400422.pdf 5998833240267527 0000-0001-5197-0347 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Revista CEFAC |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
422-431 application/pdf |
dc.publisher.none.fl_str_mv |
ABRAMO Associação Brasileira de Motricidade Orofacial |
publisher.none.fl_str_mv |
ABRAMO Associação Brasileira de Motricidade Orofacial |
dc.source.none.fl_str_mv |
SciELO reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128586601725952 |