An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.2116/analsci.25.897 http://hdl.handle.net/11449/25864 |
Resumo: | This paper describes a green analytical procedure for the determination of bumetanide using diffuse reflectance spectroscopy. The proposed method is based on reflectance measurements of a violet compound produced from a spot test reaction between bumetanide and p-dimethylaminocinnamaldehyde (p-DAC) in an acid medium, using filter paper as a solid support. The best conditions for the reaction have been found by experimental design methodologies. All reflectance measurements were carried out at 525 nm, and the linear range was from 1.37 x 10(-4) to 1.37 x 10(-3) mol L(-1). with a correlation coefficient of 0.998. The detection limit was estimated to be 3.98 x 10(-5) mol L(-1). Five commercial medicines containing bumetanide were analyzed by the proposed method. No interferences were observed from the common excipients present in pharmaceutical formulations. The results were favorably compared with those obtained by the United States Pharmacopoeia procedure at 95% confidence level. |
id |
UNSP_5be27094801500d17f9079dc323356e8 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/25864 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in PharmaceuticalsThis paper describes a green analytical procedure for the determination of bumetanide using diffuse reflectance spectroscopy. The proposed method is based on reflectance measurements of a violet compound produced from a spot test reaction between bumetanide and p-dimethylaminocinnamaldehyde (p-DAC) in an acid medium, using filter paper as a solid support. The best conditions for the reaction have been found by experimental design methodologies. All reflectance measurements were carried out at 525 nm, and the linear range was from 1.37 x 10(-4) to 1.37 x 10(-3) mol L(-1). with a correlation coefficient of 0.998. The detection limit was estimated to be 3.98 x 10(-5) mol L(-1). Five commercial medicines containing bumetanide were analyzed by the proposed method. No interferences were observed from the common excipients present in pharmaceutical formulations. The results were favorably compared with those obtained by the United States Pharmacopoeia procedure at 95% confidence level.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)São Paulo State Univ, UNESP, Inst Chem Araraquara, BR-14801970 Araraquara, SP, BrazilSão Paulo State Univ, UNESP, Inst Chem Araraquara, BR-14801970 Araraquara, SP, BrazilJapan Soc Analytical ChemistryUniversidade Estadual Paulista (Unesp)Pollo, Fernanda [UNESP]Sequinel, Rodrigo [UNESP]Rufino, Jose Luiz [UNESP]Los Weinert, Patricia [UNESP]Pezza, Helena Redigolo [UNESP]Pezza, Leonardo [UNESP]2014-05-20T14:19:26Z2014-05-20T14:19:26Z2009-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article897-901http://dx.doi.org/10.2116/analsci.25.897Analytical Sciences. Tokyo: Japan Soc Analytical Chemistry, v. 25, n. 7, p. 897-901, 2009.0910-6340http://hdl.handle.net/11449/2586410.2116/analsci.25.897WOS:000268300000012319212509836112159789085918535240000-0003-0197-7369Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAnalytical Sciences1.3550,424info:eu-repo/semantics/openAccess2021-10-22T19:32:41Zoai:repositorio.unesp.br:11449/25864Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:03:33.363775Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
title |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
spellingShingle |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals Pollo, Fernanda [UNESP] |
title_short |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
title_full |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
title_fullStr |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
title_full_unstemmed |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
title_sort |
An Environmentally Friendly Reflectometric Method for Bumetanide Determination in Pharmaceuticals |
author |
Pollo, Fernanda [UNESP] |
author_facet |
Pollo, Fernanda [UNESP] Sequinel, Rodrigo [UNESP] Rufino, Jose Luiz [UNESP] Los Weinert, Patricia [UNESP] Pezza, Helena Redigolo [UNESP] Pezza, Leonardo [UNESP] |
author_role |
author |
author2 |
Sequinel, Rodrigo [UNESP] Rufino, Jose Luiz [UNESP] Los Weinert, Patricia [UNESP] Pezza, Helena Redigolo [UNESP] Pezza, Leonardo [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Pollo, Fernanda [UNESP] Sequinel, Rodrigo [UNESP] Rufino, Jose Luiz [UNESP] Los Weinert, Patricia [UNESP] Pezza, Helena Redigolo [UNESP] Pezza, Leonardo [UNESP] |
description |
This paper describes a green analytical procedure for the determination of bumetanide using diffuse reflectance spectroscopy. The proposed method is based on reflectance measurements of a violet compound produced from a spot test reaction between bumetanide and p-dimethylaminocinnamaldehyde (p-DAC) in an acid medium, using filter paper as a solid support. The best conditions for the reaction have been found by experimental design methodologies. All reflectance measurements were carried out at 525 nm, and the linear range was from 1.37 x 10(-4) to 1.37 x 10(-3) mol L(-1). with a correlation coefficient of 0.998. The detection limit was estimated to be 3.98 x 10(-5) mol L(-1). Five commercial medicines containing bumetanide were analyzed by the proposed method. No interferences were observed from the common excipients present in pharmaceutical formulations. The results were favorably compared with those obtained by the United States Pharmacopoeia procedure at 95% confidence level. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-07-01 2014-05-20T14:19:26Z 2014-05-20T14:19:26Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.2116/analsci.25.897 Analytical Sciences. Tokyo: Japan Soc Analytical Chemistry, v. 25, n. 7, p. 897-901, 2009. 0910-6340 http://hdl.handle.net/11449/25864 10.2116/analsci.25.897 WOS:000268300000012 3192125098361121 5978908591853524 0000-0003-0197-7369 |
url |
http://dx.doi.org/10.2116/analsci.25.897 http://hdl.handle.net/11449/25864 |
identifier_str_mv |
Analytical Sciences. Tokyo: Japan Soc Analytical Chemistry, v. 25, n. 7, p. 897-901, 2009. 0910-6340 10.2116/analsci.25.897 WOS:000268300000012 3192125098361121 5978908591853524 0000-0003-0197-7369 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Analytical Sciences 1.355 0,424 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
897-901 |
dc.publisher.none.fl_str_mv |
Japan Soc Analytical Chemistry |
publisher.none.fl_str_mv |
Japan Soc Analytical Chemistry |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128747728011264 |