Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study

Detalhes bibliográficos
Autor(a) principal: Ibelli, Guilherme Siqueira
Data de Publicação: 2017
Outros Autores: Assaf, Fátimah, Santos, Anne Beatriz Souza, Santos, Michele Bastos Porto, Oliveira, Guilherme José Pimentel Lopes De, Margonar, Rogério, Queiroz, Thallita Pereira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/1807-2577.04017
http://hdl.handle.net/11449/157852
Resumo: AbstractObjective To evaluate and correlate the values of radiographic bone density, peri-implant bone height and resonance frequency analysis (RFA) of short or conventional implants placed in the posterior region of the mandible after installing a prosthesis.Material and method Eleven patients were selected for this prospective parallel pilot study. The prostheses were supported by two types of implants: short implants (n = 18) (5.0 x 5.5 mm and 5.0 x 7.0 mm) and conventional implants (n = 23) (4.0 x10 mm and 4.0 x 11.5 mm). The implants were evaluated by RFA, by measuring the bone height, and peri-implant bone density. The implants were evaluated at the periods T0 (immediately after installation of the prosthesis), T1 (after 90 days), and T2 (after 180 days).Result There were no statistically significant differences between groups with respect to radiographic bone density (152.50 ± 15.39 vs. 157.60 ± 28.46, for conventional and short implants, respectively at T2), stability of the implants (Conventional implants: 66.76 ± 10.39 at T0, and 61.85 ± 8.38 at T2 vs. Short implants: 57.50 ± 12.17 at T0, and 61.53 ± 7.39 at T2) and peri-implant bone loss (0.03 mm vs.-0.17 mm, for conventional and short implants, respectively at T2). Additionally, a significant correlation between the evaluated parameters was not detected.Conclusion The short and conventional implants presented similar stability, bone level and density after the activation of occlusion loading.
id UNSP_620fda7978e995a67889ad6e4b40d60a
oai_identifier_str oai:repositorio.unesp.br:11449/157852
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot studyComparação clínica de implantes curtos e convencionais instalados na região posterior da mandíbula. Estudo pilotoBone resorptionbone densityprostheses and implantsReabsorção ósseadensidade ósseapróteses e implantesAbstractObjective To evaluate and correlate the values of radiographic bone density, peri-implant bone height and resonance frequency analysis (RFA) of short or conventional implants placed in the posterior region of the mandible after installing a prosthesis.Material and method Eleven patients were selected for this prospective parallel pilot study. The prostheses were supported by two types of implants: short implants (n = 18) (5.0 x 5.5 mm and 5.0 x 7.0 mm) and conventional implants (n = 23) (4.0 x10 mm and 4.0 x 11.5 mm). The implants were evaluated by RFA, by measuring the bone height, and peri-implant bone density. The implants were evaluated at the periods T0 (immediately after installation of the prosthesis), T1 (after 90 days), and T2 (after 180 days).Result There were no statistically significant differences between groups with respect to radiographic bone density (152.50 ± 15.39 vs. 157.60 ± 28.46, for conventional and short implants, respectively at T2), stability of the implants (Conventional implants: 66.76 ± 10.39 at T0, and 61.85 ± 8.38 at T2 vs. Short implants: 57.50 ± 12.17 at T0, and 61.53 ± 7.39 at T2) and peri-implant bone loss (0.03 mm vs.-0.17 mm, for conventional and short implants, respectively at T2). Additionally, a significant correlation between the evaluated parameters was not detected.Conclusion The short and conventional implants presented similar stability, bone level and density after the activation of occlusion loading.ResumoObjetivo Avaliar e correlacionar os valores de densidade óssea radiográfica, altura óssea peri-implantar e de frequência de ressonância nos implantes curtos e convencionais instalados na região posterior da mandíbula após a instalação da prótese provisória.Material e método Esse estudo piloto clínico prospectivo contou com a participação de 11 pacientes que foram divididos previamente em dois grupos: implantes curtos (n=18) (5,0 x 5,5 mm e 5,0 x 7,0 mm) e implantes convencionais (n=23) (4,0 x 10 mm e 4,0 x 11,5 mm). Foram executadas análise da frequência de ressonância, altura óssea e densidade óssea peri-implantar. Os implantes foram avaliados nos períodos T0 (imediatamente após a instalação do provisório), T1 (após 90 dias) e T2 (após 180 dias).Resultado Não houve diferenças estatisticamente significativas entre os grupos com relação a densidade óssea radiográfica (152,50 ± 15,39 vs. 157,60 ± 28,46, para implantes convencionais e curtos respectivamente no período T2), estabilidade dos implantes (Implantes convencionais: 66,76 ± 10,39 no período T0 e 61,85 ± 8,38 no período T2 vs. Implantes curtos: 57,50 ± 12,17 no período T0 e 61,53 ± 7,39 no período T2) e quanto a perda óssea periimplantar (0,03 mm vs. -0,17 mm, em implantes convencionais e curtos no período T2, respectivamente). Adicionalmente a isso, não foram detectados correlação significativa entre densidade radiográfica com altura óssea peri-implantar e nem com a frequência de ressonância.Conclusão Verificou-se que os implantes curtos apresentaram um comportamento semelhante aos implantes de comprimento convencionais com relação à frequência de ressonância, a densidade radiográfica peri-implantar e a manutenção dos níveis ósseos periimplantares.Universidade de Araraquara Curso de OdontologiaUniversidade Estadual Paulista Faculdade de Odontologia de AraraquaraUniversidade Estadual Paulista Faculdade de Odontologia de AraraquaraUniversidade Estadual Paulista Júlio de Mesquita FilhoUniversidade de Araraquara Curso de OdontologiaUniversidade Estadual Paulista (Unesp)Ibelli, Guilherme SiqueiraAssaf, FátimahSantos, Anne Beatriz SouzaSantos, Michele Bastos PortoOliveira, Guilherme José Pimentel Lopes DeMargonar, RogérioQueiroz, Thallita Pereira2018-11-12T17:27:13Z2018-11-12T17:27:13Z2017-12-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article319-324application/pdfhttp://dx.doi.org/10.1590/1807-2577.04017Revista de Odontologia da UNESP. Universidade Estadual Paulista Júlio de Mesquita Filho, v. 46, n. 6, p. 319-324, 2017.1807-2577http://hdl.handle.net/11449/15785210.1590/1807-2577.04017S1807-25772017000600319S1807-25772017000600319.pdfSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengRevista de Odontologia da UNESPinfo:eu-repo/semantics/openAccess2024-01-26T06:33:20Zoai:repositorio.unesp.br:11449/157852Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-06T00:02:15.795918Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
Comparação clínica de implantes curtos e convencionais instalados na região posterior da mandíbula. Estudo piloto
title Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
spellingShingle Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
Ibelli, Guilherme Siqueira
Bone resorption
bone density
prostheses and implants
Reabsorção óssea
densidade óssea
próteses e implantes
title_short Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
title_full Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
title_fullStr Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
title_full_unstemmed Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
title_sort Clinical comparison of short and conventional implants placed in the posterior region of the mandible. A pilot study
author Ibelli, Guilherme Siqueira
author_facet Ibelli, Guilherme Siqueira
Assaf, Fátimah
Santos, Anne Beatriz Souza
Santos, Michele Bastos Porto
Oliveira, Guilherme José Pimentel Lopes De
Margonar, Rogério
Queiroz, Thallita Pereira
author_role author
author2 Assaf, Fátimah
Santos, Anne Beatriz Souza
Santos, Michele Bastos Porto
Oliveira, Guilherme José Pimentel Lopes De
Margonar, Rogério
Queiroz, Thallita Pereira
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade de Araraquara Curso de Odontologia
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Ibelli, Guilherme Siqueira
Assaf, Fátimah
Santos, Anne Beatriz Souza
Santos, Michele Bastos Porto
Oliveira, Guilherme José Pimentel Lopes De
Margonar, Rogério
Queiroz, Thallita Pereira
dc.subject.por.fl_str_mv Bone resorption
bone density
prostheses and implants
Reabsorção óssea
densidade óssea
próteses e implantes
topic Bone resorption
bone density
prostheses and implants
Reabsorção óssea
densidade óssea
próteses e implantes
description AbstractObjective To evaluate and correlate the values of radiographic bone density, peri-implant bone height and resonance frequency analysis (RFA) of short or conventional implants placed in the posterior region of the mandible after installing a prosthesis.Material and method Eleven patients were selected for this prospective parallel pilot study. The prostheses were supported by two types of implants: short implants (n = 18) (5.0 x 5.5 mm and 5.0 x 7.0 mm) and conventional implants (n = 23) (4.0 x10 mm and 4.0 x 11.5 mm). The implants were evaluated by RFA, by measuring the bone height, and peri-implant bone density. The implants were evaluated at the periods T0 (immediately after installation of the prosthesis), T1 (after 90 days), and T2 (after 180 days).Result There were no statistically significant differences between groups with respect to radiographic bone density (152.50 ± 15.39 vs. 157.60 ± 28.46, for conventional and short implants, respectively at T2), stability of the implants (Conventional implants: 66.76 ± 10.39 at T0, and 61.85 ± 8.38 at T2 vs. Short implants: 57.50 ± 12.17 at T0, and 61.53 ± 7.39 at T2) and peri-implant bone loss (0.03 mm vs.-0.17 mm, for conventional and short implants, respectively at T2). Additionally, a significant correlation between the evaluated parameters was not detected.Conclusion The short and conventional implants presented similar stability, bone level and density after the activation of occlusion loading.
publishDate 2017
dc.date.none.fl_str_mv 2017-12-01
2018-11-12T17:27:13Z
2018-11-12T17:27:13Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1807-2577.04017
Revista de Odontologia da UNESP. Universidade Estadual Paulista Júlio de Mesquita Filho, v. 46, n. 6, p. 319-324, 2017.
1807-2577
http://hdl.handle.net/11449/157852
10.1590/1807-2577.04017
S1807-25772017000600319
S1807-25772017000600319.pdf
url http://dx.doi.org/10.1590/1807-2577.04017
http://hdl.handle.net/11449/157852
identifier_str_mv Revista de Odontologia da UNESP. Universidade Estadual Paulista Júlio de Mesquita Filho, v. 46, n. 6, p. 319-324, 2017.
1807-2577
10.1590/1807-2577.04017
S1807-25772017000600319
S1807-25772017000600319.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Revista de Odontologia da UNESP
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 319-324
application/pdf
dc.publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
publisher.none.fl_str_mv Universidade Estadual Paulista Júlio de Mesquita Filho
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129574931791872