Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/159322 |
Resumo: | In this paper, a new mixed integer linear programming formulation is proposed to optimally control the Volt-VAr control devices installed in a balanced electrical distribution system (EDS), taking into account the presence of dispatchable distributed generation (DG) units. The formulation considers a voltage dependent load model and aims to reduce the cost of the energy purchased to the substation and DG units on a daylong time period. The proposed method defines the settings for the voltage regulators, on-load tap changer, capacitors, and DG units. The presented formulation was tested in a 42-node EDS and the obtained results prove that the methodology enhances the EDS economic operation with a very low computational effort. |
id |
UNSP_62b3686725fdcd69c12757c05b0d6f6b |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/159322 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load ModelEnergy cost reductionmixed integer linear programmingvolt-var control operationvoltage dependent load modelIn this paper, a new mixed integer linear programming formulation is proposed to optimally control the Volt-VAr control devices installed in a balanced electrical distribution system (EDS), taking into account the presence of dispatchable distributed generation (DG) units. The formulation considers a voltage dependent load model and aims to reduce the cost of the energy purchased to the substation and DG units on a daylong time period. The proposed method defines the settings for the voltage regulators, on-load tap changer, capacitors, and DG units. The presented formulation was tested in a 42-node EDS and the obtained results prove that the methodology enhances the EDS economic operation with a very low computational effort.Paulista State Univ UNESP, Fac Engn Ilha Solteira, Sao Paulo, BrazilUniv Estadual Campinas, UNICAMP, Sch Elect & Comp Engn, Sao Paulo, BrazilPaulista State Univ UNESP, Fac Engn Ilha Solteira, Sao Paulo, BrazilIeeeUniversidade Estadual Paulista (Unesp)Universidade Estadual de Campinas (UNICAMP)Antunez, Carlos Sabillon [UNESP]Melgar Dominguez, Ozy D. [UNESP]Franco, John P. [UNESP]Lavorato, MarinaRider, Marcos J.IEEE2018-11-26T15:37:58Z2018-11-26T15:37:58Z2016-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject62016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016.2381-3571http://hdl.handle.net/11449/159322WOS:000392658600025Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la)info:eu-repo/semantics/openAccess2021-10-23T21:44:27Zoai:repositorio.unesp.br:11449/159322Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T23:50:10.143529Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
title |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
spellingShingle |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model Antunez, Carlos Sabillon [UNESP] Energy cost reduction mixed integer linear programming volt-var control operation voltage dependent load model |
title_short |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
title_full |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
title_fullStr |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
title_full_unstemmed |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
title_sort |
Optimal Volt-VAr Control Operation for Finergy Cost Reduction in Distribution Systems Considering a Voltage Dependent Load Model |
author |
Antunez, Carlos Sabillon [UNESP] |
author_facet |
Antunez, Carlos Sabillon [UNESP] Melgar Dominguez, Ozy D. [UNESP] Franco, John P. [UNESP] Lavorato, Marina Rider, Marcos J. IEEE |
author_role |
author |
author2 |
Melgar Dominguez, Ozy D. [UNESP] Franco, John P. [UNESP] Lavorato, Marina Rider, Marcos J. IEEE |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade Estadual de Campinas (UNICAMP) |
dc.contributor.author.fl_str_mv |
Antunez, Carlos Sabillon [UNESP] Melgar Dominguez, Ozy D. [UNESP] Franco, John P. [UNESP] Lavorato, Marina Rider, Marcos J. IEEE |
dc.subject.por.fl_str_mv |
Energy cost reduction mixed integer linear programming volt-var control operation voltage dependent load model |
topic |
Energy cost reduction mixed integer linear programming volt-var control operation voltage dependent load model |
description |
In this paper, a new mixed integer linear programming formulation is proposed to optimally control the Volt-VAr control devices installed in a balanced electrical distribution system (EDS), taking into account the presence of dispatchable distributed generation (DG) units. The formulation considers a voltage dependent load model and aims to reduce the cost of the energy purchased to the substation and DG units on a daylong time period. The proposed method defines the settings for the voltage regulators, on-load tap changer, capacitors, and DG units. The presented formulation was tested in a 42-node EDS and the obtained results prove that the methodology enhances the EDS economic operation with a very low computational effort. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-01-01 2018-11-26T15:37:58Z 2018-11-26T15:37:58Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016. 2381-3571 http://hdl.handle.net/11449/159322 WOS:000392658600025 |
identifier_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016. 2381-3571 WOS:000392658600025 |
url |
http://hdl.handle.net/11449/159322 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
6 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129557271674880 |