Resumo: | The problem addressed in this paper focuses on the reduction of electrical energy costs for the operation of hydraulic pumps, which are used for catchment and distribution of water in water supply systems. As the electricity tariffs are different according to the time of day, it is necessary to decide when and how many pumps must be used to collect and distribute water, in each period of time, and, when there must be water transfer among tanks so that the demand of each consumer center is met without a lack of resources. A mixed integer programming (MIP) model is proposed and a competitive MIP-based heuristic is developed to solve this problem. Numerical tests in a case study carried out with the water supply system of a Brazilian city demonstrate the efficiency of the proposed mathematical model and solution method. |
id |
UNSP_740adc6c4b41a616cf0c832e4a8d8564 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/198905 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
A mixed integer programming model and solution method for the operation of an integrated water supply systemhydraulic pumpsmixed integer programmingwater supply systemThe problem addressed in this paper focuses on the reduction of electrical energy costs for the operation of hydraulic pumps, which are used for catchment and distribution of water in water supply systems. As the electricity tariffs are different according to the time of day, it is necessary to decide when and how many pumps must be used to collect and distribute water, in each period of time, and, when there must be water transfer among tanks so that the demand of each consumer center is met without a lack of resources. A mixed integer programming (MIP) model is proposed and a competitive MIP-based heuristic is developed to solve this problem. Numerical tests in a case study carried out with the water supply system of a Brazilian city demonstrate the efficiency of the proposed mathematical model and solution method.Department of Applied Mathematics and Statistics University of São Paulo (USP), Av. Trabalhador São-carlense, 400Department of Mathematics Universidade Estadual Paulista (UNESP), Av. Luiz Edmundo Carrijo Coube, 14-01Department of Computer Science Universidade Federal da Grande Dourados, Rodovia Dourados/Itahum, Km 12Department of Electrical and Computer Engineering University of São Paulo (USP), Av. Trabalhador São-carlense, 400Department of Mathematics Universidade Estadual Paulista (UNESP), Av. Luiz Edmundo Carrijo Coube, 14-01Universidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Universidade Federal da Grande DouradosSantos, Maristela O.Soler, Edilaine M. [UNESP]Furlan, Marcos M.Viera, José C.M.2020-12-12T01:25:10Z2020-12-12T01:25:10Z2020-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1111/itor.12813International Transactions in Operational Research.1475-39950969-6016http://hdl.handle.net/11449/19890510.1111/itor.128132-s2.0-85085608759Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Transactions in Operational Researchinfo:eu-repo/semantics/openAccess2021-10-22T20:56:23Zoai:repositorio.unesp.br:11449/198905Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T21:05:22.733250Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
title |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
spellingShingle |
A mixed integer programming model and solution method for the operation of an integrated water supply system Santos, Maristela O. hydraulic pumps mixed integer programming water supply system |
title_short |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
title_full |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
title_fullStr |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
title_full_unstemmed |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
title_sort |
A mixed integer programming model and solution method for the operation of an integrated water supply system |
author |
Santos, Maristela O. |
author_facet |
Santos, Maristela O. Soler, Edilaine M. [UNESP] Furlan, Marcos M. Viera, José C.M. |
author_role |
author |
author2 |
Soler, Edilaine M. [UNESP] Furlan, Marcos M. Viera, José C.M. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade de São Paulo (USP) Universidade Estadual Paulista (Unesp) Universidade Federal da Grande Dourados |
dc.contributor.author.fl_str_mv |
Santos, Maristela O. Soler, Edilaine M. [UNESP] Furlan, Marcos M. Viera, José C.M. |
dc.subject.por.fl_str_mv |
hydraulic pumps mixed integer programming water supply system |
topic |
hydraulic pumps mixed integer programming water supply system |
description |
The problem addressed in this paper focuses on the reduction of electrical energy costs for the operation of hydraulic pumps, which are used for catchment and distribution of water in water supply systems. As the electricity tariffs are different according to the time of day, it is necessary to decide when and how many pumps must be used to collect and distribute water, in each period of time, and, when there must be water transfer among tanks so that the demand of each consumer center is met without a lack of resources. A mixed integer programming (MIP) model is proposed and a competitive MIP-based heuristic is developed to solve this problem. Numerical tests in a case study carried out with the water supply system of a Brazilian city demonstrate the efficiency of the proposed mathematical model and solution method. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-12T01:25:10Z 2020-12-12T01:25:10Z 2020-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1111/itor.12813 International Transactions in Operational Research. 1475-3995 0969-6016 http://hdl.handle.net/11449/198905 10.1111/itor.12813 2-s2.0-85085608759 |
url |
http://dx.doi.org/10.1111/itor.12813 http://hdl.handle.net/11449/198905 |
identifier_str_mv |
International Transactions in Operational Research. 1475-3995 0969-6016 10.1111/itor.12813 2-s2.0-85085608759 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
International Transactions in Operational Research |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129283112042496 |