Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions

Detalhes bibliográficos
Autor(a) principal: Caron, William-Olivier
Data de Publicação: 2016
Outros Autores: Lamhamedi, Mohammed S., Viens, Jeff, Messaddeq, Younès
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.3390/s16081190
http://hdl.handle.net/11449/220666
Resumo: The reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery.
id UNSP_7a1fcd4fc2dc0984fc4e64d53b66f6c0
oai_identifier_str oai:repositorio.unesp.br:11449/220666
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditionsElectrochemical impedance spectroscopyElectrochemical sensorForest nurseryGrowing mediumNitrateThe reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery.Department of Chemistry Laval UniversityMinistère des Forêts de la Faune et des Parcs Direction de la recherché forestièreCentre for Optics Photonics and Lasers (COPL) Laval UniversityJIRU Instituto de QuimicaLaval UniversityDirection de la recherché forestièreJIRU Instituto de QuimicaCaron, William-OlivierLamhamedi, Mohammed S.Viens, JeffMessaddeq, Younès2022-04-28T19:04:23Z2022-04-28T19:04:23Z2016-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.3390/s16081190Sensors (Switzerland), v. 16, n. 8, 2016.1424-8220http://hdl.handle.net/11449/22066610.3390/s160811902-s2.0-84979955406Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengSensors (Switzerland)info:eu-repo/semantics/openAccess2022-04-28T19:04:23Zoai:repositorio.unesp.br:11449/220666Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T14:11:21.927683Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
title Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
spellingShingle Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
Caron, William-Olivier
Electrochemical impedance spectroscopy
Electrochemical sensor
Forest nursery
Growing medium
Nitrate
title_short Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
title_full Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
title_fullStr Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
title_full_unstemmed Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
title_sort Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
author Caron, William-Olivier
author_facet Caron, William-Olivier
Lamhamedi, Mohammed S.
Viens, Jeff
Messaddeq, Younès
author_role author
author2 Lamhamedi, Mohammed S.
Viens, Jeff
Messaddeq, Younès
author2_role author
author
author
dc.contributor.none.fl_str_mv Laval University
Direction de la recherché forestière
JIRU Instituto de Quimica
dc.contributor.author.fl_str_mv Caron, William-Olivier
Lamhamedi, Mohammed S.
Viens, Jeff
Messaddeq, Younès
dc.subject.por.fl_str_mv Electrochemical impedance spectroscopy
Electrochemical sensor
Forest nursery
Growing medium
Nitrate
topic Electrochemical impedance spectroscopy
Electrochemical sensor
Forest nursery
Growing medium
Nitrate
description The reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery.
publishDate 2016
dc.date.none.fl_str_mv 2016-08-01
2022-04-28T19:04:23Z
2022-04-28T19:04:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.3390/s16081190
Sensors (Switzerland), v. 16, n. 8, 2016.
1424-8220
http://hdl.handle.net/11449/220666
10.3390/s16081190
2-s2.0-84979955406
url http://dx.doi.org/10.3390/s16081190
http://hdl.handle.net/11449/220666
identifier_str_mv Sensors (Switzerland), v. 16, n. 8, 2016.
1424-8220
10.3390/s16081190
2-s2.0-84979955406
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Sensors (Switzerland)
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128329878863872