Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.3390/s16081190 http://hdl.handle.net/11449/220666 |
Resumo: | The reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery. |
id |
UNSP_7a1fcd4fc2dc0984fc4e64d53b66f6c0 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/220666 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditionsElectrochemical impedance spectroscopyElectrochemical sensorForest nurseryGrowing mediumNitrateThe reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery.Department of Chemistry Laval UniversityMinistère des Forêts de la Faune et des Parcs Direction de la recherché forestièreCentre for Optics Photonics and Lasers (COPL) Laval UniversityJIRU Instituto de QuimicaLaval UniversityDirection de la recherché forestièreJIRU Instituto de QuimicaCaron, William-OlivierLamhamedi, Mohammed S.Viens, JeffMessaddeq, Younès2022-04-28T19:04:23Z2022-04-28T19:04:23Z2016-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.3390/s16081190Sensors (Switzerland), v. 16, n. 8, 2016.1424-8220http://hdl.handle.net/11449/22066610.3390/s160811902-s2.0-84979955406Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengSensors (Switzerland)info:eu-repo/semantics/openAccess2022-04-28T19:04:23Zoai:repositorio.unesp.br:11449/220666Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T14:11:21.927683Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
title |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
spellingShingle |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions Caron, William-Olivier Electrochemical impedance spectroscopy Electrochemical sensor Forest nursery Growing medium Nitrate |
title_short |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
title_full |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
title_fullStr |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
title_full_unstemmed |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
title_sort |
Practical application of electrochemical nitrate sensor under laboratory and forest nursery conditions |
author |
Caron, William-Olivier |
author_facet |
Caron, William-Olivier Lamhamedi, Mohammed S. Viens, Jeff Messaddeq, Younès |
author_role |
author |
author2 |
Lamhamedi, Mohammed S. Viens, Jeff Messaddeq, Younès |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Laval University Direction de la recherché forestière JIRU Instituto de Quimica |
dc.contributor.author.fl_str_mv |
Caron, William-Olivier Lamhamedi, Mohammed S. Viens, Jeff Messaddeq, Younès |
dc.subject.por.fl_str_mv |
Electrochemical impedance spectroscopy Electrochemical sensor Forest nursery Growing medium Nitrate |
topic |
Electrochemical impedance spectroscopy Electrochemical sensor Forest nursery Growing medium Nitrate |
description |
The reduction of nitrate leaching to ensure greater protection of groundwater quality has become a global issue. The development of new technologies for more accurate dosing of nitrates helps optimize fertilization programs. This paper presents the practical application of a newly developed electrochemical sensor designed for in situ quantification of nitrate. To our knowledge, this paper is the first to report the use of electrochemical impedance to determine nitrate concentrations in growing media under forest nursery conditions. Using impedance measurements, the sensor has been tested in laboratory and compared to colorimetric measurements of the nitrate. The developed sensor has been used in water-saturated growing medium and showed good correlation to certified methods, even in samples obtained over a multi-ion fertilisation season. A linear and significant relationship was observed between the resistance and the concentration of nitrates (R2 = 0.972), for a range of concentrations of nitrates. We also observed stability of the sensor after exposure of one month to the real environmental conditions of the forest nursery. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-08-01 2022-04-28T19:04:23Z 2022-04-28T19:04:23Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.3390/s16081190 Sensors (Switzerland), v. 16, n. 8, 2016. 1424-8220 http://hdl.handle.net/11449/220666 10.3390/s16081190 2-s2.0-84979955406 |
url |
http://dx.doi.org/10.3390/s16081190 http://hdl.handle.net/11449/220666 |
identifier_str_mv |
Sensors (Switzerland), v. 16, n. 8, 2016. 1424-8220 10.3390/s16081190 2-s2.0-84979955406 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Sensors (Switzerland) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128329878863872 |