In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers

Detalhes bibliográficos
Autor(a) principal: Pierre, Fernanda Zapater [UNESP]
Data de Publicação: 2023
Outros Autores: Demachkia, Amir Mohidin [UNESP], Tanaka, Lucas Eigi Borges [UNESP], Caneppele, Taciana Marco Ferraz [UNESP], Araujo, Rodrigo Maximo de [UNESP], Silva, Joao Mauricio Ferraz da [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.11607/ijp.7616
http://hdl.handle.net/11449/245594
Resumo: Purpose: To assess the influence of two preparation techniques on the microleakage, marginal fit, and cement thickness of lithium disilicate veneers. Materials and Methods: A total of 24 human maxillary central incisors were divided randomly into two groups according to preparation technique (n = 12 each): a minimally invasive preparation with a butt-joint design (0.3-mm depth) and a chamfer finish line (group MP); and no preparation (group NP). All teeth were restored with lithium disilicate veneers cemented with photopolymerizable resin cement. Specimens were aged thermally (6,000 cycles of 5 degrees C to 55 degrees C) and mechanically (100,000 cycles at 100 N, 4 Hz). Specimens were immersed in fuchsin dye for 24 hours using a standard dye penetration technique, then sectioned and evaluated under a stereomicroscope (x20 magnification). Data were analyzed by ANOVA and Kruskal-Wallis tests (P < .05). Results: There was significant microleakage (P = .0163) at the cervical area compared to the proximal area. The marginal fit was similar, with no statistical difference (P = .212) between groups MP (153 +/- 81 pm) and NP (111 +/- 74 pm). Group MP showed a significantly (P= .006) reduced cement thickness at the cervical area (87 +/- 27 pm) compared to group NP (210 +/- 89 pm). Conclusion: Although the preparation technique was shown to influence the cement thickness, it did not show any influence on microleakage or marginal fit. Intl Prosthodont 2023;36:63-70. doi: 10.11607/ijp.7616
id UNSP_9d65dc44cafd83720d410f4563534e47
oai_identifier_str oai:repositorio.unesp.br:11449/245594
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate VeneersPurpose: To assess the influence of two preparation techniques on the microleakage, marginal fit, and cement thickness of lithium disilicate veneers. Materials and Methods: A total of 24 human maxillary central incisors were divided randomly into two groups according to preparation technique (n = 12 each): a minimally invasive preparation with a butt-joint design (0.3-mm depth) and a chamfer finish line (group MP); and no preparation (group NP). All teeth were restored with lithium disilicate veneers cemented with photopolymerizable resin cement. Specimens were aged thermally (6,000 cycles of 5 degrees C to 55 degrees C) and mechanically (100,000 cycles at 100 N, 4 Hz). Specimens were immersed in fuchsin dye for 24 hours using a standard dye penetration technique, then sectioned and evaluated under a stereomicroscope (x20 magnification). Data were analyzed by ANOVA and Kruskal-Wallis tests (P < .05). Results: There was significant microleakage (P = .0163) at the cervical area compared to the proximal area. The marginal fit was similar, with no statistical difference (P = .212) between groups MP (153 +/- 81 pm) and NP (111 +/- 74 pm). Group MP showed a significantly (P= .006) reduced cement thickness at the cervical area (87 +/- 27 pm) compared to group NP (210 +/- 89 pm). Conclusion: Although the preparation technique was shown to influence the cement thickness, it did not show any influence on microleakage or marginal fit. Intl Prosthodont 2023;36:63-70. doi: 10.11607/ijp.7616Human Research Ethics Committee of the Institute of Science and Technology of Sao Jose dos Campos of the Sao Paulo State UniversitySao Paulo State Univ UNESP, Inst Sci & Technol, Program Sci Appl Oral Hlth Prosthodont, Sao Jose Dos Campos, SP, BrazilUNESP, Inst Sci & Technol, Dept Restorat Dent, Sao Jose Dos Campos, SP, BrazilUNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, BrazilSao Paulo State Univ UNESP, Inst Sci & Technol, Program Sci Appl Oral Hlth Prosthodont, Sao Jose Dos Campos, SP, BrazilUNESP, Inst Sci & Technol, Dept Restorat Dent, Sao Jose Dos Campos, SP, BrazilUNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP, BrazilHuman Research Ethics Committee of the Institute of Science and Technology of Sao Jose dos Campos of the Sao Paulo State University: 2.538.520Quintessence Publishing Co IncUniversidade Estadual Paulista (UNESP)Pierre, Fernanda Zapater [UNESP]Demachkia, Amir Mohidin [UNESP]Tanaka, Lucas Eigi Borges [UNESP]Caneppele, Taciana Marco Ferraz [UNESP]Araujo, Rodrigo Maximo de [UNESP]Silva, Joao Mauricio Ferraz da [UNESP]2023-07-29T11:59:20Z2023-07-29T11:59:20Z2023-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article63-70http://dx.doi.org/10.11607/ijp.7616International Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 36, n. 1, p. 63-70, 2023.0893-2174http://hdl.handle.net/11449/24559410.11607/ijp.7616WOS:000942830300007Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengInternational Journal Of Prosthodonticsinfo:eu-repo/semantics/openAccess2023-07-29T11:59:20Zoai:repositorio.unesp.br:11449/245594Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T23:11:55.250215Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
title In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
spellingShingle In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
Pierre, Fernanda Zapater [UNESP]
title_short In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
title_full In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
title_fullStr In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
title_full_unstemmed In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
title_sort In Vitro Comparison of Microleakage, Marginal Fit, and Cement Thickness of Conventional and Prepless Lithium Disilicate Veneers
author Pierre, Fernanda Zapater [UNESP]
author_facet Pierre, Fernanda Zapater [UNESP]
Demachkia, Amir Mohidin [UNESP]
Tanaka, Lucas Eigi Borges [UNESP]
Caneppele, Taciana Marco Ferraz [UNESP]
Araujo, Rodrigo Maximo de [UNESP]
Silva, Joao Mauricio Ferraz da [UNESP]
author_role author
author2 Demachkia, Amir Mohidin [UNESP]
Tanaka, Lucas Eigi Borges [UNESP]
Caneppele, Taciana Marco Ferraz [UNESP]
Araujo, Rodrigo Maximo de [UNESP]
Silva, Joao Mauricio Ferraz da [UNESP]
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Pierre, Fernanda Zapater [UNESP]
Demachkia, Amir Mohidin [UNESP]
Tanaka, Lucas Eigi Borges [UNESP]
Caneppele, Taciana Marco Ferraz [UNESP]
Araujo, Rodrigo Maximo de [UNESP]
Silva, Joao Mauricio Ferraz da [UNESP]
description Purpose: To assess the influence of two preparation techniques on the microleakage, marginal fit, and cement thickness of lithium disilicate veneers. Materials and Methods: A total of 24 human maxillary central incisors were divided randomly into two groups according to preparation technique (n = 12 each): a minimally invasive preparation with a butt-joint design (0.3-mm depth) and a chamfer finish line (group MP); and no preparation (group NP). All teeth were restored with lithium disilicate veneers cemented with photopolymerizable resin cement. Specimens were aged thermally (6,000 cycles of 5 degrees C to 55 degrees C) and mechanically (100,000 cycles at 100 N, 4 Hz). Specimens were immersed in fuchsin dye for 24 hours using a standard dye penetration technique, then sectioned and evaluated under a stereomicroscope (x20 magnification). Data were analyzed by ANOVA and Kruskal-Wallis tests (P < .05). Results: There was significant microleakage (P = .0163) at the cervical area compared to the proximal area. The marginal fit was similar, with no statistical difference (P = .212) between groups MP (153 +/- 81 pm) and NP (111 +/- 74 pm). Group MP showed a significantly (P= .006) reduced cement thickness at the cervical area (87 +/- 27 pm) compared to group NP (210 +/- 89 pm). Conclusion: Although the preparation technique was shown to influence the cement thickness, it did not show any influence on microleakage or marginal fit. Intl Prosthodont 2023;36:63-70. doi: 10.11607/ijp.7616
publishDate 2023
dc.date.none.fl_str_mv 2023-07-29T11:59:20Z
2023-07-29T11:59:20Z
2023-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.11607/ijp.7616
International Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 36, n. 1, p. 63-70, 2023.
0893-2174
http://hdl.handle.net/11449/245594
10.11607/ijp.7616
WOS:000942830300007
url http://dx.doi.org/10.11607/ijp.7616
http://hdl.handle.net/11449/245594
identifier_str_mv International Journal of Prosthodontics. Hanover Park: Quintessence Publishing Co Inc, v. 36, n. 1, p. 63-70, 2023.
0893-2174
10.11607/ijp.7616
WOS:000942830300007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv International Journal Of Prosthodontics
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 63-70
dc.publisher.none.fl_str_mv Quintessence Publishing Co Inc
publisher.none.fl_str_mv Quintessence Publishing Co Inc
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129498644742144