Resumo: | Metribuzin is a widely used pesticide with a half-life of up to 2 months and high affinity to organic matter that should be carefully monitored. Here is reported the development of a modified carbon paste electrode using cobalt phthalocyanine as a biomimetic catalyst for the determination of metribuzin. The diffusion coefficient of metribuzin at room temperature was (59 ± 16) × 10−6 cm2 s−1 and the apparent Michaelis–Menten constant (Kap M) was (7.4 ± 0.6) × 10−6 mol L−1. Electroanalytical measurements were performed by amperometry and the following figures of merit were obtained: limit of detection of 5.3 × 10−6 mol L−1 (1.14 mg L−1), linear range up to 2.0 × 10−4 mol L−1, recoveries above 93% (performed on spiked water samples), interday repeatability of 4.5% and intraday repeatability of 3.5%, and suitable selectivity. |
id |
UNSP_a82d6d662ac3153d68b3cd2157c418ff |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/176074 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste ElectrodeBiomimetic sensorcyclic voltammetryelectroanalysiselectrocatalysismetallophthalocyanine complexesMetribuzin is a widely used pesticide with a half-life of up to 2 months and high affinity to organic matter that should be carefully monitored. Here is reported the development of a modified carbon paste electrode using cobalt phthalocyanine as a biomimetic catalyst for the determination of metribuzin. The diffusion coefficient of metribuzin at room temperature was (59 ± 16) × 10−6 cm2 s−1 and the apparent Michaelis–Menten constant (Kap M) was (7.4 ± 0.6) × 10−6 mol L−1. Electroanalytical measurements were performed by amperometry and the following figures of merit were obtained: limit of detection of 5.3 × 10−6 mol L−1 (1.14 mg L−1), linear range up to 2.0 × 10−4 mol L−1, recoveries above 93% (performed on spiked water samples), interday repeatability of 4.5% and intraday repeatability of 3.5%, and suitable selectivity.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação para a Ciência e a TecnologiaDepartment of Analytical Chemistry Institute of Chemistry UNESP–Univ Estadual PaulistaNational Institute for Alternative Technologies of Detection Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM)REQUIMTE/LAQV Faculdade de Ciências Universidade do PortoDepartamento de Química Fundamental Instituto de Química Universidade de São Paulo (USP)Department of Analytical Chemistry Institute of Chemistry UNESP–Univ Estadual PaulistaFAPESP: 2014/25264-3FAPESP: 2016/06926-0CNPq: 303690/2012-7CNPq: 400459/2012-4Fundação para a Ciência e a Tecnologia: FCT/13277/4/8/2015/SFundação para a Ciência e a Tecnologia: SFRH/BPD/76544/2011Universidade Estadual Paulista (Unesp)Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM)Universidade do PortoUniversidade de São Paulo (USP)Figueira, Eduardo Carneiro [UNESP]Santos Ruy, Mayara Regina dos [UNESP]Wong, Ademar [UNESP]Gonçalves, Luís MoreiraSotomayor, Maria del Pilar Taboada [UNESP]2018-12-11T17:18:48Z2018-12-11T17:18:48Z2018-07-24info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1694-1704application/pdfhttp://dx.doi.org/10.1080/00032719.2017.1389950Analytical Letters, v. 51, n. 11, p. 1694-1704, 2018.1532-236X0003-2719http://hdl.handle.net/11449/17607410.1080/00032719.2017.13899502-s2.0-850444712912-s2.0-85044471291.pdf2933194342093387Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAnalytical Letters0,344info:eu-repo/semantics/openAccess2023-12-05T06:19:14Zoai:repositorio.unesp.br:11449/176074Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:33:26.153784Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
title |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
spellingShingle |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode Figueira, Eduardo Carneiro [UNESP] Biomimetic sensor cyclic voltammetry electroanalysis electrocatalysis metallophthalocyanine complexes |
title_short |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
title_full |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
title_fullStr |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
title_full_unstemmed |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
title_sort |
Determination of Metribuzin with a Cobalt Phthalocyanine-Modified Carbon Paste Electrode |
author |
Figueira, Eduardo Carneiro [UNESP] |
author_facet |
Figueira, Eduardo Carneiro [UNESP] Santos Ruy, Mayara Regina dos [UNESP] Wong, Ademar [UNESP] Gonçalves, Luís Moreira Sotomayor, Maria del Pilar Taboada [UNESP] |
author_role |
author |
author2 |
Santos Ruy, Mayara Regina dos [UNESP] Wong, Ademar [UNESP] Gonçalves, Luís Moreira Sotomayor, Maria del Pilar Taboada [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM) Universidade do Porto Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Figueira, Eduardo Carneiro [UNESP] Santos Ruy, Mayara Regina dos [UNESP] Wong, Ademar [UNESP] Gonçalves, Luís Moreira Sotomayor, Maria del Pilar Taboada [UNESP] |
dc.subject.por.fl_str_mv |
Biomimetic sensor cyclic voltammetry electroanalysis electrocatalysis metallophthalocyanine complexes |
topic |
Biomimetic sensor cyclic voltammetry electroanalysis electrocatalysis metallophthalocyanine complexes |
description |
Metribuzin is a widely used pesticide with a half-life of up to 2 months and high affinity to organic matter that should be carefully monitored. Here is reported the development of a modified carbon paste electrode using cobalt phthalocyanine as a biomimetic catalyst for the determination of metribuzin. The diffusion coefficient of metribuzin at room temperature was (59 ± 16) × 10−6 cm2 s−1 and the apparent Michaelis–Menten constant (Kap M) was (7.4 ± 0.6) × 10−6 mol L−1. Electroanalytical measurements were performed by amperometry and the following figures of merit were obtained: limit of detection of 5.3 × 10−6 mol L−1 (1.14 mg L−1), linear range up to 2.0 × 10−4 mol L−1, recoveries above 93% (performed on spiked water samples), interday repeatability of 4.5% and intraday repeatability of 3.5%, and suitable selectivity. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-11T17:18:48Z 2018-12-11T17:18:48Z 2018-07-24 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1080/00032719.2017.1389950 Analytical Letters, v. 51, n. 11, p. 1694-1704, 2018. 1532-236X 0003-2719 http://hdl.handle.net/11449/176074 10.1080/00032719.2017.1389950 2-s2.0-85044471291 2-s2.0-85044471291.pdf 2933194342093387 |
url |
http://dx.doi.org/10.1080/00032719.2017.1389950 http://hdl.handle.net/11449/176074 |
identifier_str_mv |
Analytical Letters, v. 51, n. 11, p. 1694-1704, 2018. 1532-236X 0003-2719 10.1080/00032719.2017.1389950 2-s2.0-85044471291 2-s2.0-85044471291.pdf 2933194342093387 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Analytical Letters 0,344 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1694-1704 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129086213586944 |