In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits

Detalhes bibliográficos
Autor(a) principal: Queiroz, Thallita Pereira
Data de Publicação: 2017
Outros Autores: de Molon, Rafael Scaf [UNESP], Souza, Francisley Ávila [UNESP], Margonar, Rogério, Thomazini, Anahi Herrera Aparecida [UNESP], Guastaldi, Antônio Carlos [UNESP], Hochuli-Vieira, Eduardo [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1007/s00784-016-1936-7
http://hdl.handle.net/11449/173344
Resumo: Objective: We aimed to assess the surfaces of commercially pure titanium implants (cp Ti) with modified surfaces by laser beam (LS) with and without hydroxyapatite (HA) deposition, without (HAB) and with (HABT) thermal treatment. Furthermore, we have compared them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS) utilizing histomorphometric and descriptive histologic analyses. Material and methods: Surface topography characterization was analyzed by scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDX), and surface roughness (Ra) before implant installation. Forty-five rabbits received seventy-five implants in their left and right tibias and were randomly divided into five groups (n = 5 implants per group): (1) cp Ti implant modified by LS, (2) cp Ti implant modified by laser beam associated with HA deposition without heat treatment (HAB), (3) cp Ti implant modified by laser beam associated with HA deposition with heat treatment (HABT), (4) cp Ti implant with modified surface by means of acid treatment (Master Porous) commercially available (AS), and (5) cp Ti implant with MS commercially available. After 30, 60, and 90 days, the animals were euthanized and the implants and surrounding bone were removed and prepared by a non-decalcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area fraction occupancy (BAFO) between the first three threads was evaluated to the higher cortical region. Results: BIC (%) was statistically superior (p < 0.001) on the LS (69.36 ± 7.91, 71.67 ± 8.79, and 79.69 ± 3.3), HAB (73.22 ± 3.75, 69.48 ± 1.89, and 75.7 ± 4.62), and HABT (65.41 ± 5.51, 71.3 ± 2.5, and 79.68 ± 5.01) compared with AS (49.15 ± 5.76, 41.94 ± 2.85, and 57.18 ± 7.81) and MS (36.69 ± 7.24, 52.52 ± 2.75, and 51.31 ± 6.96) in the 30, 60, and 90-day periods, respectively. BAFO (%) of HAB at 30 days (90.17 ± 6.24) was statistically superior (p < 0.01) to all the other groups. At 60 and 90 days, BAFO of LS (87.17 ± 5.9 and 87.99 ± 2.52), HAB (85.95 ± 3.93 and 82.17 ± 3.65), and HABT (83.27 ± 1.44 and 88.67 ± 2.67) was higher than the AS (77.49 ± 5.83 and 76.42 ± 5.98) and MS (74.01 ± 4.68 and 73.81 ± 4.91). Conclusions: Collectively, our data indicate that the modified surfaces LS, HAB, and HABT favored the interaction between bone and implant and increased bone formation. In addition, HAB showed higher biological behavior favoring the osseointegration. Clinical relevance: Our study provides evidence that LS, HAB, and HABT-modified surfaces improved bone-to-implant contact and increased bone formation around osseointegrated implants compared to conventional machined implants favoring the osseointegration process.
id UNSP_b75fe1bb2e8e615a9a7e806e59379efc
oai_identifier_str oai:repositorio.unesp.br:11449/173344
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbitsDental implantationHistomorphometric analysisHydroxyapatiteLaserSurface propertiesObjective: We aimed to assess the surfaces of commercially pure titanium implants (cp Ti) with modified surfaces by laser beam (LS) with and without hydroxyapatite (HA) deposition, without (HAB) and with (HABT) thermal treatment. Furthermore, we have compared them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS) utilizing histomorphometric and descriptive histologic analyses. Material and methods: Surface topography characterization was analyzed by scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDX), and surface roughness (Ra) before implant installation. Forty-five rabbits received seventy-five implants in their left and right tibias and were randomly divided into five groups (n = 5 implants per group): (1) cp Ti implant modified by LS, (2) cp Ti implant modified by laser beam associated with HA deposition without heat treatment (HAB), (3) cp Ti implant modified by laser beam associated with HA deposition with heat treatment (HABT), (4) cp Ti implant with modified surface by means of acid treatment (Master Porous) commercially available (AS), and (5) cp Ti implant with MS commercially available. After 30, 60, and 90 days, the animals were euthanized and the implants and surrounding bone were removed and prepared by a non-decalcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area fraction occupancy (BAFO) between the first three threads was evaluated to the higher cortical region. Results: BIC (%) was statistically superior (p < 0.001) on the LS (69.36 ± 7.91, 71.67 ± 8.79, and 79.69 ± 3.3), HAB (73.22 ± 3.75, 69.48 ± 1.89, and 75.7 ± 4.62), and HABT (65.41 ± 5.51, 71.3 ± 2.5, and 79.68 ± 5.01) compared with AS (49.15 ± 5.76, 41.94 ± 2.85, and 57.18 ± 7.81) and MS (36.69 ± 7.24, 52.52 ± 2.75, and 51.31 ± 6.96) in the 30, 60, and 90-day periods, respectively. BAFO (%) of HAB at 30 days (90.17 ± 6.24) was statistically superior (p < 0.01) to all the other groups. At 60 and 90 days, BAFO of LS (87.17 ± 5.9 and 87.99 ± 2.52), HAB (85.95 ± 3.93 and 82.17 ± 3.65), and HABT (83.27 ± 1.44 and 88.67 ± 2.67) was higher than the AS (77.49 ± 5.83 and 76.42 ± 5.98) and MS (74.01 ± 4.68 and 73.81 ± 4.91). Conclusions: Collectively, our data indicate that the modified surfaces LS, HAB, and HABT favored the interaction between bone and implant and increased bone formation. In addition, HAB showed higher biological behavior favoring the osseointegration. Clinical relevance: Our study provides evidence that LS, HAB, and HABT-modified surfaces improved bone-to-implant contact and increased bone formation around osseointegrated implants compared to conventional machined implants favoring the osseointegration process.Department of Health Sciences Implantology Post Graduation Course Dental School University Center of Araraquara (UNIARA), Avenida Jose Bonifacio, 128Department of Diagnosis and Surgery School of Dentistry at Araraquara Sao Paulo State University (UNESP), Rua Humaitá 1680Department of Surgery School of Dentistry at Araçatuba Sao Paulo State University (UNESP)Biomaterials Group Physical-Chemistry Department Chemistry Institute of Araraquara Sao Paulo State University (UNESP)Department of Diagnosis and Surgery School of Dentistry at Araraquara Sao Paulo State University (UNESP), Rua Humaitá 1680Department of Surgery School of Dentistry at Araçatuba Sao Paulo State University (UNESP)Biomaterials Group Physical-Chemistry Department Chemistry Institute of Araraquara Sao Paulo State University (UNESP)University Center of Araraquara (UNIARA)Universidade Estadual Paulista (Unesp)Queiroz, Thallita Pereirade Molon, Rafael Scaf [UNESP]Souza, Francisley Ávila [UNESP]Margonar, RogérioThomazini, Anahi Herrera Aparecida [UNESP]Guastaldi, Antônio Carlos [UNESP]Hochuli-Vieira, Eduardo [UNESP]2018-12-11T17:04:45Z2018-12-11T17:04:45Z2017-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article685-699application/pdfhttp://dx.doi.org/10.1007/s00784-016-1936-7Clinical Oral Investigations, v. 21, n. 2, p. 685-699, 2017.1436-37711432-6981http://hdl.handle.net/11449/17334410.1007/s00784-016-1936-72-s2.0-849821662472-s2.0-84982166247.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengClinical Oral Investigations0,9860,986info:eu-repo/semantics/openAccess2024-09-26T15:21:38Zoai:repositorio.unesp.br:11449/173344Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T15:21:38Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
title In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
spellingShingle In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
Queiroz, Thallita Pereira
Dental implantation
Histomorphometric analysis
Hydroxyapatite
Laser
Surface properties
title_short In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
title_full In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
title_fullStr In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
title_full_unstemmed In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
title_sort In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits
author Queiroz, Thallita Pereira
author_facet Queiroz, Thallita Pereira
de Molon, Rafael Scaf [UNESP]
Souza, Francisley Ávila [UNESP]
Margonar, Rogério
Thomazini, Anahi Herrera Aparecida [UNESP]
Guastaldi, Antônio Carlos [UNESP]
Hochuli-Vieira, Eduardo [UNESP]
author_role author
author2 de Molon, Rafael Scaf [UNESP]
Souza, Francisley Ávila [UNESP]
Margonar, Rogério
Thomazini, Anahi Herrera Aparecida [UNESP]
Guastaldi, Antônio Carlos [UNESP]
Hochuli-Vieira, Eduardo [UNESP]
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv University Center of Araraquara (UNIARA)
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Queiroz, Thallita Pereira
de Molon, Rafael Scaf [UNESP]
Souza, Francisley Ávila [UNESP]
Margonar, Rogério
Thomazini, Anahi Herrera Aparecida [UNESP]
Guastaldi, Antônio Carlos [UNESP]
Hochuli-Vieira, Eduardo [UNESP]
dc.subject.por.fl_str_mv Dental implantation
Histomorphometric analysis
Hydroxyapatite
Laser
Surface properties
topic Dental implantation
Histomorphometric analysis
Hydroxyapatite
Laser
Surface properties
description Objective: We aimed to assess the surfaces of commercially pure titanium implants (cp Ti) with modified surfaces by laser beam (LS) with and without hydroxyapatite (HA) deposition, without (HAB) and with (HABT) thermal treatment. Furthermore, we have compared them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS) utilizing histomorphometric and descriptive histologic analyses. Material and methods: Surface topography characterization was analyzed by scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDX), and surface roughness (Ra) before implant installation. Forty-five rabbits received seventy-five implants in their left and right tibias and were randomly divided into five groups (n = 5 implants per group): (1) cp Ti implant modified by LS, (2) cp Ti implant modified by laser beam associated with HA deposition without heat treatment (HAB), (3) cp Ti implant modified by laser beam associated with HA deposition with heat treatment (HABT), (4) cp Ti implant with modified surface by means of acid treatment (Master Porous) commercially available (AS), and (5) cp Ti implant with MS commercially available. After 30, 60, and 90 days, the animals were euthanized and the implants and surrounding bone were removed and prepared by a non-decalcified histological process. The percentage of bone-to-implant contact (BIC) and the bone area fraction occupancy (BAFO) between the first three threads was evaluated to the higher cortical region. Results: BIC (%) was statistically superior (p < 0.001) on the LS (69.36 ± 7.91, 71.67 ± 8.79, and 79.69 ± 3.3), HAB (73.22 ± 3.75, 69.48 ± 1.89, and 75.7 ± 4.62), and HABT (65.41 ± 5.51, 71.3 ± 2.5, and 79.68 ± 5.01) compared with AS (49.15 ± 5.76, 41.94 ± 2.85, and 57.18 ± 7.81) and MS (36.69 ± 7.24, 52.52 ± 2.75, and 51.31 ± 6.96) in the 30, 60, and 90-day periods, respectively. BAFO (%) of HAB at 30 days (90.17 ± 6.24) was statistically superior (p < 0.01) to all the other groups. At 60 and 90 days, BAFO of LS (87.17 ± 5.9 and 87.99 ± 2.52), HAB (85.95 ± 3.93 and 82.17 ± 3.65), and HABT (83.27 ± 1.44 and 88.67 ± 2.67) was higher than the AS (77.49 ± 5.83 and 76.42 ± 5.98) and MS (74.01 ± 4.68 and 73.81 ± 4.91). Conclusions: Collectively, our data indicate that the modified surfaces LS, HAB, and HABT favored the interaction between bone and implant and increased bone formation. In addition, HAB showed higher biological behavior favoring the osseointegration. Clinical relevance: Our study provides evidence that LS, HAB, and HABT-modified surfaces improved bone-to-implant contact and increased bone formation around osseointegrated implants compared to conventional machined implants favoring the osseointegration process.
publishDate 2017
dc.date.none.fl_str_mv 2017-03-01
2018-12-11T17:04:45Z
2018-12-11T17:04:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1007/s00784-016-1936-7
Clinical Oral Investigations, v. 21, n. 2, p. 685-699, 2017.
1436-3771
1432-6981
http://hdl.handle.net/11449/173344
10.1007/s00784-016-1936-7
2-s2.0-84982166247
2-s2.0-84982166247.pdf
url http://dx.doi.org/10.1007/s00784-016-1936-7
http://hdl.handle.net/11449/173344
identifier_str_mv Clinical Oral Investigations, v. 21, n. 2, p. 685-699, 2017.
1436-3771
1432-6981
10.1007/s00784-016-1936-7
2-s2.0-84982166247
2-s2.0-84982166247.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Clinical Oral Investigations
0,986
0,986
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 685-699
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546449502208000