Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://dx.doi.org/10.1016/j.talanta.2020.121241 http://hdl.handle.net/11449/210407 |
Resumo: | Venous thromboembolism (VTE) is a serious clinical condition which early and accurate diagnosis may contribute to the reduction of associated morbidity and mortality. VTE occurs when a blood clot (thrombus) blocks the vein blood flow causing deep vein thrombosis (DVT) and, when it migrates to the lungs, it may clog the pulmonary arteries characterizing pulmonary embolism (PE). Analysis using fibrin degradation products or D-dimer and coagulation factor VIII may assist early diagnosis of VTE. Thus, two immunosensors were built using layer-by-layer (LbL) films technique, one containing the anti-D-dimer immobilized on polyethylene imine (PEI) and another the anti-FVIII on silk fibroin (SF). Immunosensor response, the antigen-antibody specific interaction, was investigated using cyclic voltammetry. When immunosensors, PEI/anti-D-dimer and SF/anti-FVIII, were exposed to antigens, D-dimer and Factor VIII, the voltammograms area and current were significantly increased with increasing specific antigen concentration. The specific interaction was confirmed with control experiments, electrodes containing only PEI or SF, that no significant changes in the voltammogram responses were observed and principal component analysis confirmed these results. The films formation and response were verified using scanning electronic microscopy (SEM). The developed immunosensor seems to be a promising and effective early complementary exam to assist in the VTE diagnosis, through the combined response of two biomarkers very sensible. |
id |
UNSP_bd96ec114d68b4363183402916265319 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/210407 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensorVenous thromboembolismImmunosensorFactor VIIIFibrin degradation productsD-dimerDiagnosisVoltammetric sensorsVenous thromboembolism (VTE) is a serious clinical condition which early and accurate diagnosis may contribute to the reduction of associated morbidity and mortality. VTE occurs when a blood clot (thrombus) blocks the vein blood flow causing deep vein thrombosis (DVT) and, when it migrates to the lungs, it may clog the pulmonary arteries characterizing pulmonary embolism (PE). Analysis using fibrin degradation products or D-dimer and coagulation factor VIII may assist early diagnosis of VTE. Thus, two immunosensors were built using layer-by-layer (LbL) films technique, one containing the anti-D-dimer immobilized on polyethylene imine (PEI) and another the anti-FVIII on silk fibroin (SF). Immunosensor response, the antigen-antibody specific interaction, was investigated using cyclic voltammetry. When immunosensors, PEI/anti-D-dimer and SF/anti-FVIII, were exposed to antigens, D-dimer and Factor VIII, the voltammograms area and current were significantly increased with increasing specific antigen concentration. The specific interaction was confirmed with control experiments, electrodes containing only PEI or SF, that no significant changes in the voltammogram responses were observed and principal component analysis confirmed these results. The films formation and response were verified using scanning electronic microscopy (SEM). The developed immunosensor seems to be a promising and effective early complementary exam to assist in the VTE diagnosis, through the combined response of two biomarkers very sensible.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Univ Fed Sao Paulo, Inst Ciencia & Tecnol, Sao Jose Dos Campos, SP, BrazilUniv Sao Paulo, Inst Fis Sao Carlos, Sao Carlos, SP, BrazilUniv Estadual Paulista, Inst Quim, Araraquara, SP, BrazilUniv Estadual Paulista, Hemoctr Botucatu, Botucatu, SP, BrazilUniv Estadual Paulista, Inst Quim, Araraquara, SP, BrazilUniv Estadual Paulista, Hemoctr Botucatu, Botucatu, SP, BrazilFAPESP: 2014/03145-2CNPq: 480896/2013-5Elsevier B.V.Universidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Universidade Estadual Paulista (Unesp)Yokomichi, Anna Laura YuriRodrigues, Valquiria da CruzMoroz, Andrei [UNESP]Bertanha, Matheus [UNESP]Ribeiro, Sidney J. L. [UNESP]Deffune, Elenice [UNESP]Moraes, Marli L.2021-06-25T15:07:41Z2021-06-25T15:07:41Z2020-11-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article8http://dx.doi.org/10.1016/j.talanta.2020.121241Talanta. Amsterdam: Elsevier, v. 219, 8 p., 2020.0039-9140http://hdl.handle.net/11449/21040710.1016/j.talanta.2020.121241WOS:000568748700008Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengTalantainfo:eu-repo/semantics/openAccess2021-10-23T20:17:28Zoai:repositorio.unesp.br:11449/210407Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T16:13:39.241411Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
title |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
spellingShingle |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor Yokomichi, Anna Laura Yuri Venous thromboembolism Immunosensor Factor VIII Fibrin degradation products D-dimer Diagnosis Voltammetric sensors |
title_short |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
title_full |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
title_fullStr |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
title_full_unstemmed |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
title_sort |
Detection of factor VIII and D-dimer biomarkers for venous thromboembolism diagnosis using electrochemistry immunosensor |
author |
Yokomichi, Anna Laura Yuri |
author_facet |
Yokomichi, Anna Laura Yuri Rodrigues, Valquiria da Cruz Moroz, Andrei [UNESP] Bertanha, Matheus [UNESP] Ribeiro, Sidney J. L. [UNESP] Deffune, Elenice [UNESP] Moraes, Marli L. |
author_role |
author |
author2 |
Rodrigues, Valquiria da Cruz Moroz, Andrei [UNESP] Bertanha, Matheus [UNESP] Ribeiro, Sidney J. L. [UNESP] Deffune, Elenice [UNESP] Moraes, Marli L. |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Universidade de São Paulo (USP) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Yokomichi, Anna Laura Yuri Rodrigues, Valquiria da Cruz Moroz, Andrei [UNESP] Bertanha, Matheus [UNESP] Ribeiro, Sidney J. L. [UNESP] Deffune, Elenice [UNESP] Moraes, Marli L. |
dc.subject.por.fl_str_mv |
Venous thromboembolism Immunosensor Factor VIII Fibrin degradation products D-dimer Diagnosis Voltammetric sensors |
topic |
Venous thromboembolism Immunosensor Factor VIII Fibrin degradation products D-dimer Diagnosis Voltammetric sensors |
description |
Venous thromboembolism (VTE) is a serious clinical condition which early and accurate diagnosis may contribute to the reduction of associated morbidity and mortality. VTE occurs when a blood clot (thrombus) blocks the vein blood flow causing deep vein thrombosis (DVT) and, when it migrates to the lungs, it may clog the pulmonary arteries characterizing pulmonary embolism (PE). Analysis using fibrin degradation products or D-dimer and coagulation factor VIII may assist early diagnosis of VTE. Thus, two immunosensors were built using layer-by-layer (LbL) films technique, one containing the anti-D-dimer immobilized on polyethylene imine (PEI) and another the anti-FVIII on silk fibroin (SF). Immunosensor response, the antigen-antibody specific interaction, was investigated using cyclic voltammetry. When immunosensors, PEI/anti-D-dimer and SF/anti-FVIII, were exposed to antigens, D-dimer and Factor VIII, the voltammograms area and current were significantly increased with increasing specific antigen concentration. The specific interaction was confirmed with control experiments, electrodes containing only PEI or SF, that no significant changes in the voltammogram responses were observed and principal component analysis confirmed these results. The films formation and response were verified using scanning electronic microscopy (SEM). The developed immunosensor seems to be a promising and effective early complementary exam to assist in the VTE diagnosis, through the combined response of two biomarkers very sensible. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-11-01 2021-06-25T15:07:41Z 2021-06-25T15:07:41Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.talanta.2020.121241 Talanta. Amsterdam: Elsevier, v. 219, 8 p., 2020. 0039-9140 http://hdl.handle.net/11449/210407 10.1016/j.talanta.2020.121241 WOS:000568748700008 |
url |
http://dx.doi.org/10.1016/j.talanta.2020.121241 http://hdl.handle.net/11449/210407 |
identifier_str_mv |
Talanta. Amsterdam: Elsevier, v. 219, 8 p., 2020. 0039-9140 10.1016/j.talanta.2020.121241 WOS:000568748700008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Talanta |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
8 |
dc.publisher.none.fl_str_mv |
Elsevier B.V. |
publisher.none.fl_str_mv |
Elsevier B.V. |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128621735313408 |