An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/162386 |
Resumo: | This paper presents a mixed-integer linear programming model to define the optimal operation of energy storage devices in radial distribution systems. The objective considered is the reduction of the energy purchase cost from the distribution substation. The modeling of the energy storage devices determines both the charging and discharging periods, and the injected and extracted power. In addition, the number of daily charge/discharge cycles of the storage devices is limited to avoid an excessive reduction of their lifespan. The proposed model was used to analyze the influence of the location of energy storage devices in the operation of a system. The efficiency of the methodology was tested in several cases, using a 136-node distribution system. |
id |
UNSP_c06b2f924f2ee13646d9a4b28157a61a |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/162386 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution SystemsEnergy storage devicesmixed-integer linear programmingoperation of distribution systemsThis paper presents a mixed-integer linear programming model to define the optimal operation of energy storage devices in radial distribution systems. The objective considered is the reduction of the energy purchase cost from the distribution substation. The modeling of the energy storage devices determines both the charging and discharging periods, and the injected and extracted power. In addition, the number of daily charge/discharge cycles of the storage devices is limited to avoid an excessive reduction of their lifespan. The proposed model was used to analyze the influence of the location of energy storage devices in the operation of a system. The efficiency of the methodology was tested in several cases, using a 136-node distribution system.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Sao Paulo State Univ, Dept Elect Engn, Ilha Solteira, BrazilUniv Estadual Campinas, Dept Syst & Energy, Campinas, SP, BrazilSao Paulo State Univ, Dept Elect Engn, Ilha Solteira, BrazilFAPESP: 2014/23741-9IeeeUniversidade Estadual Paulista (Unesp)Universidade Estadual de Campinas (UNICAMP)Macedo, Leonardo H. [UNESP]Franco, John F. [UNESP]Romero, Ruben [UNESP]Rider, Marcos J.IEEE2018-11-26T17:16:28Z2018-11-26T17:16:28Z2016-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject62016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016.2381-3571http://hdl.handle.net/11449/162386WOS:000392658600013Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPeng2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la)info:eu-repo/semantics/openAccess2024-07-04T19:11:18Zoai:repositorio.unesp.br:11449/162386Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T14:36:15.877152Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
title |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
spellingShingle |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems Macedo, Leonardo H. [UNESP] Energy storage devices mixed-integer linear programming operation of distribution systems |
title_short |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
title_full |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
title_fullStr |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
title_full_unstemmed |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
title_sort |
An MILP Model for the Analysis of Operation of Energy Storage Devices in Distribution Systems |
author |
Macedo, Leonardo H. [UNESP] |
author_facet |
Macedo, Leonardo H. [UNESP] Franco, John F. [UNESP] Romero, Ruben [UNESP] Rider, Marcos J. IEEE |
author_role |
author |
author2 |
Franco, John F. [UNESP] Romero, Ruben [UNESP] Rider, Marcos J. IEEE |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) Universidade Estadual de Campinas (UNICAMP) |
dc.contributor.author.fl_str_mv |
Macedo, Leonardo H. [UNESP] Franco, John F. [UNESP] Romero, Ruben [UNESP] Rider, Marcos J. IEEE |
dc.subject.por.fl_str_mv |
Energy storage devices mixed-integer linear programming operation of distribution systems |
topic |
Energy storage devices mixed-integer linear programming operation of distribution systems |
description |
This paper presents a mixed-integer linear programming model to define the optimal operation of energy storage devices in radial distribution systems. The objective considered is the reduction of the energy purchase cost from the distribution substation. The modeling of the energy storage devices determines both the charging and discharging periods, and the injected and extracted power. In addition, the number of daily charge/discharge cycles of the storage devices is limited to avoid an excessive reduction of their lifespan. The proposed model was used to analyze the influence of the location of energy storage devices in the operation of a system. The efficiency of the methodology was tested in several cases, using a 136-node distribution system. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-01-01 2018-11-26T17:16:28Z 2018-11-26T17:16:28Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016. 2381-3571 http://hdl.handle.net/11449/162386 WOS:000392658600013 |
identifier_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la). New York: Ieee, 6 p., 2016. 2381-3571 WOS:000392658600013 |
url |
http://hdl.handle.net/11449/162386 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
2016 Ieee Pes Transmission & Distribution Conference And Exposition-latin America (pes T&d-la) |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
6 |
dc.publisher.none.fl_str_mv |
Ieee |
publisher.none.fl_str_mv |
Ieee |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128386613116928 |