Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence

Detalhes bibliográficos
Autor(a) principal: Mendiburu, Andrés Z. [UNESP]
Data de Publicação: 2016
Outros Autores: de Carvalho, João A. [UNESP], Coronado, Christian R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.jhazmat.2015.11.008
http://hdl.handle.net/11449/168167
Resumo: This study focuses on estimating the upper flammability limits of C-H compounds. A method was developed to determine the upper flammability limits in air at standard atmospheric pressure for the following cases: (a) estimation of the UFLs of pure C-H compounds at standard ambient temperature (25. °C); (b) estimation of the UFLs of binary mixtures of C-H compounds at standard ambient temperature (25 °C); (c) estimation of the UFLs of C-H compounds at different initial temperatures. The method was accurate in all cases. In case (a), for a total set of 115 compounds, the absolute average relative error was 7.27% and a squared correlation coefficient of 0.9248 was obtained. In case (b), the average absolute relative error was 5.55%; in case (c) it was 2.19%.
id UNSP_cc152788546275aef2a24e5641dd2d41
oai_identifier_str oai:repositorio.unesp.br:11449/168167
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependenceC-H compoundsEstimationInitial temperature effectUpper flammability limitsThis study focuses on estimating the upper flammability limits of C-H compounds. A method was developed to determine the upper flammability limits in air at standard atmospheric pressure for the following cases: (a) estimation of the UFLs of pure C-H compounds at standard ambient temperature (25. °C); (b) estimation of the UFLs of binary mixtures of C-H compounds at standard ambient temperature (25 °C); (c) estimation of the UFLs of C-H compounds at different initial temperatures. The method was accurate in all cases. In case (a), for a total set of 115 compounds, the absolute average relative error was 7.27% and a squared correlation coefficient of 0.9248 was obtained. In case (b), the average absolute relative error was 5.55%; in case (c) it was 2.19%.São Paulo State University UNESP, Campus of Guaratingueta FEG, Av. Ariberto P. da Cunha, 333Federal University of Itajubá UNIFEI Mechanical Engineering Institute, IEM Av BPS 1303São Paulo State University UNESP, Campus of Guaratingueta FEG, Av. Ariberto P. da Cunha, 333Universidade Estadual Paulista (Unesp)Mechanical Engineering InstituteMendiburu, Andrés Z. [UNESP]de Carvalho, João A. [UNESP]Coronado, Christian R.2018-12-11T16:40:02Z2018-12-11T16:40:02Z2016-03-05info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article512-521application/pdfhttp://dx.doi.org/10.1016/j.jhazmat.2015.11.008Journal of Hazardous Materials, v. 304, p. 512-521.1873-33360304-3894http://hdl.handle.net/11449/16816710.1016/j.jhazmat.2015.11.0082-s2.0-849481806282-s2.0-84948180628.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Hazardous Materials1,787info:eu-repo/semantics/openAccess2023-11-10T06:10:27Zoai:repositorio.unesp.br:11449/168167Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:17:54.528358Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
title Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
spellingShingle Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
Mendiburu, Andrés Z. [UNESP]
C-H compounds
Estimation
Initial temperature effect
Upper flammability limits
title_short Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
title_full Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
title_fullStr Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
title_full_unstemmed Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
title_sort Estimation of upper flammability limits of C-H compounds in air at standard atmospheric pressure and evaluation of temperature dependence
author Mendiburu, Andrés Z. [UNESP]
author_facet Mendiburu, Andrés Z. [UNESP]
de Carvalho, João A. [UNESP]
Coronado, Christian R.
author_role author
author2 de Carvalho, João A. [UNESP]
Coronado, Christian R.
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Mechanical Engineering Institute
dc.contributor.author.fl_str_mv Mendiburu, Andrés Z. [UNESP]
de Carvalho, João A. [UNESP]
Coronado, Christian R.
dc.subject.por.fl_str_mv C-H compounds
Estimation
Initial temperature effect
Upper flammability limits
topic C-H compounds
Estimation
Initial temperature effect
Upper flammability limits
description This study focuses on estimating the upper flammability limits of C-H compounds. A method was developed to determine the upper flammability limits in air at standard atmospheric pressure for the following cases: (a) estimation of the UFLs of pure C-H compounds at standard ambient temperature (25. °C); (b) estimation of the UFLs of binary mixtures of C-H compounds at standard ambient temperature (25 °C); (c) estimation of the UFLs of C-H compounds at different initial temperatures. The method was accurate in all cases. In case (a), for a total set of 115 compounds, the absolute average relative error was 7.27% and a squared correlation coefficient of 0.9248 was obtained. In case (b), the average absolute relative error was 5.55%; in case (c) it was 2.19%.
publishDate 2016
dc.date.none.fl_str_mv 2016-03-05
2018-12-11T16:40:02Z
2018-12-11T16:40:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.jhazmat.2015.11.008
Journal of Hazardous Materials, v. 304, p. 512-521.
1873-3336
0304-3894
http://hdl.handle.net/11449/168167
10.1016/j.jhazmat.2015.11.008
2-s2.0-84948180628
2-s2.0-84948180628.pdf
url http://dx.doi.org/10.1016/j.jhazmat.2015.11.008
http://hdl.handle.net/11449/168167
identifier_str_mv Journal of Hazardous Materials, v. 304, p. 512-521.
1873-3336
0304-3894
10.1016/j.jhazmat.2015.11.008
2-s2.0-84948180628
2-s2.0-84948180628.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Hazardous Materials
1,787
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 512-521
application/pdf
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128787132448768