Radiopacity and flow of different endodontic sealers

Detalhes bibliográficos
Autor(a) principal: Tanomaru Filho, Mario [UNESP]
Data de Publicação: 2013
Outros Autores: Bosso, Roberta [UNESP], Viapiana, Raqueli [UNESP], Guerreiro-Tanomaru, Juliane Maria [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1852-48342013000200010
http://hdl.handle.net/11449/126082
Resumo: The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.
id UNSP_d530f3d8b1720eb0216f1086546ac784
oai_identifier_str oai:repositorio.unesp.br:11449/126082
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Radiopacity and flow of different endodontic sealersRadiopacidade e escoamento dos cimentos endodónticos ah plus, endo CMP sealer, MTA fillapex, sealapex, epiphany e epiphany seEndodontic sealersRadiopacityFlowMineral trioxide aggregateCimento endodonticoRadiopacidadeEscoamentoMineral Trioxido AgregadoThe present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.O objetivo deste estudo foi avaliar a radiopacidade e o escoamento dos cimentos endodonticos: AH Plus, Endo CPM Sealer, Fillapex, Sealapex, Epiphany e Epiphany SE. Para o teste de radiopacidade foram confeccionados corpos de prova com 10mm de largura e 1mm de espessura, radiografados juntamente com uma escala de aluminio sobre filme oclusal. As imagens foram digitalizadas e foi determinada a equivalencia em milimetros de aluminio. Para avaliacao do escoamento, foram colocados 0,05 } 0,005 ml do cimento em placa de vidro, e sobre este uma massa de 120g. Foi realizada mensuracao do maior e menor diametro de cada especime e as amostras foram fotografadas e digitalizadas para mensuracao da area do cimento em mm2 pelo programa UTHSCSA Image Tool for Windows Versao 3.00. Os dados foram analisados por ANOVA e teste Tukey, com 5% de significancia. AH Plus e Epiphany SE apresentaram maior radiopacidade (12,5 mm Al e 12,0 mm Al, respectivamente) (p>0,05), seguidos pelo Epiphany (9,6 mm Al) e Fillapex (8,9 mm Al). Endo CPM (5,46 mm Al) e Sealapex (5,51 mm Al) apresentaram menor radiopacidade. O MTA Fillapex apresentou valor de escoamento superior aos demais materiais (33,11 mm e 844,9 mm2). Os cimentos AH Plus, Epiphany e Epiphany SE apresentaram valores similares e intermediarios (p>0,05), seguidos pelos cimentos Endo CPM Sealer (342,8 mm2 e 21,05 mm) e Sealapex (352,5 mm2 e 19,98 mm) que apresentaram menor escoamento (p>0,05). Todos os cimentos avaliados estao em acordo com as recomendacoes da norma ISO e ANSI/ADA.Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 - 3o Andar, Centro, CEP 14801-903, SP, BrasilUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680 - 3o Andar, Centro, CEP 14801-903, SP, BrasilUniversidade Estadual Paulista (Unesp)Tanomaru Filho, Mario [UNESP]Bosso, Roberta [UNESP]Viapiana, Raqueli [UNESP]Guerreiro-Tanomaru, Juliane Maria [UNESP]2015-08-06T16:13:54Z2015-08-06T16:13:54Z2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article121-125http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1852-48342013000200010Acta Odontológica Latinoamericana, v. 26, n. 2, p. 121-125, 2013.0326-4815http://hdl.handle.net/11449/12608279065573241789382665211298584751Currículo Lattesreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengActa Odontológica Latinoamericana0,264info:eu-repo/semantics/openAccess2021-10-22T19:57:41Zoai:repositorio.unesp.br:11449/126082Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462021-10-22T19:57:41Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Radiopacity and flow of different endodontic sealers
Radiopacidade e escoamento dos cimentos endodónticos ah plus, endo CMP sealer, MTA fillapex, sealapex, epiphany e epiphany se
title Radiopacity and flow of different endodontic sealers
spellingShingle Radiopacity and flow of different endodontic sealers
Tanomaru Filho, Mario [UNESP]
Endodontic sealers
Radiopacity
Flow
Mineral trioxide aggregate
Cimento endodontico
Radiopacidade
Escoamento
Mineral Trioxido Agregado
title_short Radiopacity and flow of different endodontic sealers
title_full Radiopacity and flow of different endodontic sealers
title_fullStr Radiopacity and flow of different endodontic sealers
title_full_unstemmed Radiopacity and flow of different endodontic sealers
title_sort Radiopacity and flow of different endodontic sealers
author Tanomaru Filho, Mario [UNESP]
author_facet Tanomaru Filho, Mario [UNESP]
Bosso, Roberta [UNESP]
Viapiana, Raqueli [UNESP]
Guerreiro-Tanomaru, Juliane Maria [UNESP]
author_role author
author2 Bosso, Roberta [UNESP]
Viapiana, Raqueli [UNESP]
Guerreiro-Tanomaru, Juliane Maria [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Tanomaru Filho, Mario [UNESP]
Bosso, Roberta [UNESP]
Viapiana, Raqueli [UNESP]
Guerreiro-Tanomaru, Juliane Maria [UNESP]
dc.subject.por.fl_str_mv Endodontic sealers
Radiopacity
Flow
Mineral trioxide aggregate
Cimento endodontico
Radiopacidade
Escoamento
Mineral Trioxido Agregado
topic Endodontic sealers
Radiopacity
Flow
Mineral trioxide aggregate
Cimento endodontico
Radiopacidade
Escoamento
Mineral Trioxido Agregado
description The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.
publishDate 2013
dc.date.none.fl_str_mv 2013
2015-08-06T16:13:54Z
2015-08-06T16:13:54Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1852-48342013000200010
Acta Odontológica Latinoamericana, v. 26, n. 2, p. 121-125, 2013.
0326-4815
http://hdl.handle.net/11449/126082
7906557324178938
2665211298584751
url http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1852-48342013000200010
http://hdl.handle.net/11449/126082
identifier_str_mv Acta Odontológica Latinoamericana, v. 26, n. 2, p. 121-125, 2013.
0326-4815
7906557324178938
2665211298584751
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Acta Odontológica Latinoamericana
0,264
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 121-125
dc.source.none.fl_str_mv Currículo Lattes
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799964509748592640