Analysis of the radiopacity of endodontic sealers using a digital radiograph system

Detalhes bibliográficos
Autor(a) principal: Sydney, Gilson Blitzkow
Data de Publicação: 2008
Outros Autores: Ferreira, Monica, Leonardi, Denise Piotto, Deonizio, Marili Doro, Batista, Antonio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356
Resumo: Purpose: This study aimed to evaluate the radiopacity of some endodontic sealers using a digital radiograph system. Methods: The endodontic sealers tested were: AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE), and Intrafill. Six cylindrical-shaped specimens (1x0.5cm) were fabricated with each material and stored at 37ºC and 100% relative humidity for 72h. Each specimen was placed at the central area of the sensor of the digital system Kodak RVG 5000, and the X-ray cylinder was positioned perpendicularly at a 5cm-focal distance with time of exposure of 0.05s. The digital image software was used to measure optical density in pixels of the specimens at their central area and at the right and left sides. Data were analyzed by ANOVA and Tukey test (α=0.05). Results: There was a statistically significant difference of radiopacity among the tested materials, except for the comparison between Intrafill and Endofill. The level of radiopacity in ascending order was: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusion: The digital radiograph method was sensitive to detect differences of radiopacity among the tested endodontic sealers. Key words: Endodontics; endodontic sealers; radiopacity
id PUC_RS-22_220dc0fe42ed994b79eb73708fe9d385
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/2356
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Analysis of the radiopacity of endodontic sealers using a digital radiograph systemAnálise da radiopacidade de cimentos endodônticos por meio de radiografia digitalEndodonticsendodontic sealersradiopacityEndodontic sealersdigital imagesPurpose: This study aimed to evaluate the radiopacity of some endodontic sealers using a digital radiograph system. Methods: The endodontic sealers tested were: AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE), and Intrafill. Six cylindrical-shaped specimens (1x0.5cm) were fabricated with each material and stored at 37ºC and 100% relative humidity for 72h. Each specimen was placed at the central area of the sensor of the digital system Kodak RVG 5000, and the X-ray cylinder was positioned perpendicularly at a 5cm-focal distance with time of exposure of 0.05s. The digital image software was used to measure optical density in pixels of the specimens at their central area and at the right and left sides. Data were analyzed by ANOVA and Tukey test (α=0.05). Results: There was a statistically significant difference of radiopacity among the tested materials, except for the comparison between Intrafill and Endofill. The level of radiopacity in ascending order was: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusion: The digital radiograph method was sensitive to detect differences of radiopacity among the tested endodontic sealers. Key words: Endodontics; endodontic sealers; radiopacityObjetivo: O presente estudo teve por finalidade analisar a radiopacidade de alguns cimentos endodônticos utilizando um sistema de radiografia digital. Metodologia: Foram testados os cimentos endodônticos AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE) e Intrafill. Seis corpos-de-prova cilídricos (1x0,5cm) para cada cimento foram confeccionados e armazenados a 37ºC e umidade relativa de 100%, durante 72h. Os corpos-de-prova foram posicionados na região central do sensor do sistema digital Kodak RVG 5000 e o cilindro do aparelho radiográfico foi posicionado perpendicularmente a uma distância focal de 5cm, com tempo de exposição de 0,05 segundos. A partir da imagem digital obtiveram-se os valores da densidade óptica em pixels da região central e pontos eqüidistantes à direita e à esquerda de cada corpo-de-prova. Os dados foram analisados por ANOVA e teste de Tukey (α=0,05). Resultados: Houve diferença estatística entre todos os cimentos, com exceção da comparação entre o Intrafill e o Endofill. A radiopacidade dos cimentos em ordem crescente foi: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusão: O método de radiografia digital foi sensível para detectar diferenças de radiopacidade entre os cimentos endodônticos analisados. Palavras-chave: Endodontia; cimentos endodônticos; radiopacidadeEDIPUCRS - Editora Universitária da PUCRS2008-08-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356Revista Odonto Ciência; Vol. 23 No. 4 (2008); 338 - 341Revista Odonto Ciência; v. 23 n. 4 (2008); 338 - 3411980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356/3431Sydney, Gilson BlitzkowFerreira, MonicaLeonardi, Denise PiottoDeonizio, Marili DoroBatista, Antonioinfo:eu-repo/semantics/openAccess2013-11-18T10:32:04Zoai:ojs.revistaseletronicas.pucrs.br:article/2356Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T10:32:04Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Analysis of the radiopacity of endodontic sealers using a digital radiograph system
Análise da radiopacidade de cimentos endodônticos por meio de radiografia digital
title Analysis of the radiopacity of endodontic sealers using a digital radiograph system
spellingShingle Analysis of the radiopacity of endodontic sealers using a digital radiograph system
Sydney, Gilson Blitzkow
Endodontics
endodontic sealers
radiopacity
Endodontic sealers
digital images
title_short Analysis of the radiopacity of endodontic sealers using a digital radiograph system
title_full Analysis of the radiopacity of endodontic sealers using a digital radiograph system
title_fullStr Analysis of the radiopacity of endodontic sealers using a digital radiograph system
title_full_unstemmed Analysis of the radiopacity of endodontic sealers using a digital radiograph system
title_sort Analysis of the radiopacity of endodontic sealers using a digital radiograph system
author Sydney, Gilson Blitzkow
author_facet Sydney, Gilson Blitzkow
Ferreira, Monica
Leonardi, Denise Piotto
Deonizio, Marili Doro
Batista, Antonio
author_role author
author2 Ferreira, Monica
Leonardi, Denise Piotto
Deonizio, Marili Doro
Batista, Antonio
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Sydney, Gilson Blitzkow
Ferreira, Monica
Leonardi, Denise Piotto
Deonizio, Marili Doro
Batista, Antonio
dc.subject.por.fl_str_mv Endodontics
endodontic sealers
radiopacity
Endodontic sealers
digital images
topic Endodontics
endodontic sealers
radiopacity
Endodontic sealers
digital images
description Purpose: This study aimed to evaluate the radiopacity of some endodontic sealers using a digital radiograph system. Methods: The endodontic sealers tested were: AH-Plus, N-Rickert, Endofill, Óxido de zinco e eugenol (OZE), and Intrafill. Six cylindrical-shaped specimens (1x0.5cm) were fabricated with each material and stored at 37ºC and 100% relative humidity for 72h. Each specimen was placed at the central area of the sensor of the digital system Kodak RVG 5000, and the X-ray cylinder was positioned perpendicularly at a 5cm-focal distance with time of exposure of 0.05s. The digital image software was used to measure optical density in pixels of the specimens at their central area and at the right and left sides. Data were analyzed by ANOVA and Tukey test (α=0.05). Results: There was a statistically significant difference of radiopacity among the tested materials, except for the comparison between Intrafill and Endofill. The level of radiopacity in ascending order was: ZOE < Endofill = Intrafill < N-Rickert < AH-Plus. Conclusion: The digital radiograph method was sensitive to detect differences of radiopacity among the tested endodontic sealers. Key words: Endodontics; endodontic sealers; radiopacity
publishDate 2008
dc.date.none.fl_str_mv 2008-08-11
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
laboratory
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2356/3431
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 23 No. 4 (2008); 338 - 341
Revista Odonto Ciência; v. 23 n. 4 (2008); 338 - 341
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820873809821696