Resumo: Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
id UNSP_e90e49085044071a7630195456b65759
oai_identifier_str oai:repositorio.unesp.br:11449/224622
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal cariesPurpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.Department of Surgery, Periodontology and Radiology School of Dentistry of São José Dos Campos-UNESP, São José dos CamposDepartment of Surgery, Periodontology and Radiology School of Dentistry of São José Dos Campos-UNESP, São José dos CamposUniversidade Estadual Paulista (UNESP)De Araujo, Elaine Aparecida Félix [UNESP]De Melo Castilho, Julio Cezar [UNESP]Medici Filho, Edmundo [UNESP]De Moraes, Mari Eli Leonelli [UNESP]2022-04-28T20:01:34Z2022-04-28T20:01:34Z2005-08-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article241-244American Journal of Dentistry, v. 18, n. 4, p. 241-244, 2005.0894-8275http://hdl.handle.net/11449/2246222-s2.0-26944431621Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengAmerican Journal of Dentistryinfo:eu-repo/semantics/openAccess2022-04-28T20:01:34Zoai:repositorio.unesp.br:11449/224622Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T20:43:10.194339Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
title Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
spellingShingle Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
De Araujo, Elaine Aparecida Félix [UNESP]
title_short Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
title_full Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
title_fullStr Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
title_full_unstemmed Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
title_sort Comparison of direct digital and conventional imaging with Ekta Speed Plus and INSIGHT films for the detection of approximal caries
author De Araujo, Elaine Aparecida Félix [UNESP]
author_facet De Araujo, Elaine Aparecida Félix [UNESP]
De Melo Castilho, Julio Cezar [UNESP]
Medici Filho, Edmundo [UNESP]
De Moraes, Mari Eli Leonelli [UNESP]
author_role author
author2 De Melo Castilho, Julio Cezar [UNESP]
Medici Filho, Edmundo [UNESP]
De Moraes, Mari Eli Leonelli [UNESP]
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv De Araujo, Elaine Aparecida Félix [UNESP]
De Melo Castilho, Julio Cezar [UNESP]
Medici Filho, Edmundo [UNESP]
De Moraes, Mari Eli Leonelli [UNESP]
description Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
publishDate 2005
dc.date.none.fl_str_mv 2005-08-01
2022-04-28T20:01:34Z
2022-04-28T20:01:34Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv American Journal of Dentistry, v. 18, n. 4, p. 241-244, 2005.
0894-8275
http://hdl.handle.net/11449/224622
2-s2.0-26944431621
identifier_str_mv American Journal of Dentistry, v. 18, n. 4, p. 241-244, 2005.
0894-8275
2-s2.0-26944431621
url http://hdl.handle.net/11449/224622
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv American Journal of Dentistry
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 241-244
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808129238413344768