Determination of lomefloxacin in tablet preparations by liquid chromatography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/219403 |
Resumo: | A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 × 4.6 mm id, 5 μ particle size) with a mobile phase composed of 1% acetic acid-acetonitrile- methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug. |
id |
UNSP_f0ccbda5ae6dee5362193668b3d520f3 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/219403 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Determination of lomefloxacin in tablet preparations by liquid chromatographyA sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 × 4.6 mm id, 5 μ particle size) with a mobile phase composed of 1% acetic acid-acetonitrile- methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.Faculdade de Ciências Farmacêuticas Programa de Pós-Graduaçâo em Ciências Farmacêuticas UNESP, Rod. Araraquara-Jaú, km 1, CEP 14801-902, Araraquara, SPFaculdade de Ciências Farmacêuticas Programa de Pós-Graduaçâo em Ciências Farmacêuticas UNESP, Rod. Araraquara-Jaú, km 1, CEP 14801-902, Araraquara, SPUniversidade Estadual Paulista (UNESP)Tozo, Greci C. G. [UNESP]Salgado, Hérida R. N. [UNESP]2022-04-28T18:55:29Z2022-04-28T18:55:29Z2006-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article1305-1308Journal of AOAC International, v. 89, n. 5, p. 1305-1308, 2006.1060-3271http://hdl.handle.net/11449/2194032-s2.0-33749818278Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of AOAC Internationalinfo:eu-repo/semantics/openAccess2022-04-28T18:55:29Zoai:repositorio.unesp.br:11449/219403Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T19:14:06.521715Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
title |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
spellingShingle |
Determination of lomefloxacin in tablet preparations by liquid chromatography Tozo, Greci C. G. [UNESP] |
title_short |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
title_full |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
title_fullStr |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
title_full_unstemmed |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
title_sort |
Determination of lomefloxacin in tablet preparations by liquid chromatography |
author |
Tozo, Greci C. G. [UNESP] |
author_facet |
Tozo, Greci C. G. [UNESP] Salgado, Hérida R. N. [UNESP] |
author_role |
author |
author2 |
Salgado, Hérida R. N. [UNESP] |
author2_role |
author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Tozo, Greci C. G. [UNESP] Salgado, Hérida R. N. [UNESP] |
description |
A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 × 4.6 mm id, 5 μ particle size) with a mobile phase composed of 1% acetic acid-acetonitrile- methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-09-01 2022-04-28T18:55:29Z 2022-04-28T18:55:29Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Journal of AOAC International, v. 89, n. 5, p. 1305-1308, 2006. 1060-3271 http://hdl.handle.net/11449/219403 2-s2.0-33749818278 |
identifier_str_mv |
Journal of AOAC International, v. 89, n. 5, p. 1305-1308, 2006. 1060-3271 2-s2.0-33749818278 |
url |
http://hdl.handle.net/11449/219403 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of AOAC International |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
1305-1308 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808129038333509632 |