Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring

Detalhes bibliográficos
Autor(a) principal: Yamamoto, Priscila Akemi [UNESP]
Data de Publicação: 2021
Outros Autores: Benzi, Jhohann Richard de Lima, de Moraes, Natália Valadares [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.4322/2179-443X.0717
http://hdl.handle.net/11449/207701
Resumo: Aim: We aimed to develop methods to determine gabapentin (GAB) in biological samples using high-performance liquid chromatography (HPLC) with application in pharmacokinetics and therapeutic drug monitoring. Methods: Simple, rapid and efficient HPLC-UV methods to quantify GAB in human plasma and urine were developed and validated for clinical analysis of GAB. The 1-fluoro-2,4-dinitrobenzene (FDNB) was used as derivatization agent. For plasma samples, protein precipitation using acetonitrile was performed, before the derivatization reaction. Urine samples were cleaned-up by liquid-liquid extraction with dichloromethane:n-butanol (1:1, v/v) after derivatized. Amlodipine besilate was used as internal standard (IS). Results: Gabapentin and IS were resolved on LiChrospher® C18 RP column and a mixture of 50 mM sodium phosphate buffer (pH 3.9):methanol (27:73, v/v) as mobile phase, at 1.2 mL/min. The methods used small sample volumes, 100 and 50 µL of plasma and urine, respectively. Linearity was obtained in the interval of 0.2-14 µg/mL in plasma and 2-120 µg/mL in urine. Both methods showed to be selective, without carry-over effect, precise, accurate and stable in different conditions. GAB plasma concentration in patients receiving 600 to 3600 mg/day of GAB ranged between 0.40 to 11.94 µg/mL at steady-state. Conclusions: The methods described in this study were simple, rapid and fulfill all validation requirements. They were easily and successfully applied for population pharmacokinetics and therapeutic drug monitoring of GAB in patients with chronic pain.
id UNSP_f0e3bfdeebd97afd1b6c72ad1d7e31fd
oai_identifier_str oai:repositorio.unesp.br:11449/207701
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoringGabapentinHPLCPlasmaUrineAim: We aimed to develop methods to determine gabapentin (GAB) in biological samples using high-performance liquid chromatography (HPLC) with application in pharmacokinetics and therapeutic drug monitoring. Methods: Simple, rapid and efficient HPLC-UV methods to quantify GAB in human plasma and urine were developed and validated for clinical analysis of GAB. The 1-fluoro-2,4-dinitrobenzene (FDNB) was used as derivatization agent. For plasma samples, protein precipitation using acetonitrile was performed, before the derivatization reaction. Urine samples were cleaned-up by liquid-liquid extraction with dichloromethane:n-butanol (1:1, v/v) after derivatized. Amlodipine besilate was used as internal standard (IS). Results: Gabapentin and IS were resolved on LiChrospher® C18 RP column and a mixture of 50 mM sodium phosphate buffer (pH 3.9):methanol (27:73, v/v) as mobile phase, at 1.2 mL/min. The methods used small sample volumes, 100 and 50 µL of plasma and urine, respectively. Linearity was obtained in the interval of 0.2-14 µg/mL in plasma and 2-120 µg/mL in urine. Both methods showed to be selective, without carry-over effect, precise, accurate and stable in different conditions. GAB plasma concentration in patients receiving 600 to 3600 mg/day of GAB ranged between 0.40 to 11.94 µg/mL at steady-state. Conclusions: The methods described in this study were simple, rapid and fulfill all validation requirements. They were easily and successfully applied for population pharmacokinetics and therapeutic drug monitoring of GAB in patients with chronic pain.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Departamento de Fármacos e Medicamentos Faculdade de Ciências Farmacêuticas Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)Departamento de Análises Clínicas Toxicológicas e Bromatológicas Faculdade de Ciências Farmacêuticas de Ribeirão Preto Universidade de São Paulo (USP)Departamento de Fármacos e Medicamentos Faculdade de Ciências Farmacêuticas Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP)CAPES: 001FAPESP: 2015/25728-2Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Yamamoto, Priscila Akemi [UNESP]Benzi, Jhohann Richard de Limade Moraes, Natália Valadares [UNESP]2021-06-25T10:59:31Z2021-06-25T10:59:31Z2021-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.4322/2179-443X.0717Revista de Ciencias Farmaceuticas Basica e Aplicada, v. 42.2179-443X1808-4532http://hdl.handle.net/11449/20770110.4322/2179-443X.07172-s2.0-85105390895Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengRevista de Ciencias Farmaceuticas Basica e Aplicadainfo:eu-repo/semantics/openAccess2024-06-24T13:45:18Zoai:repositorio.unesp.br:11449/207701Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T15:37:55.137892Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
title Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
spellingShingle Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
Yamamoto, Priscila Akemi [UNESP]
Gabapentin
HPLC
Plasma
Urine
title_short Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
title_full Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
title_fullStr Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
title_full_unstemmed Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
title_sort Simple and rapid hplc-uv methods for gabapentin quantification in human plasma and urine: Applicability in pharmacokinetics and drug monitoring
author Yamamoto, Priscila Akemi [UNESP]
author_facet Yamamoto, Priscila Akemi [UNESP]
Benzi, Jhohann Richard de Lima
de Moraes, Natália Valadares [UNESP]
author_role author
author2 Benzi, Jhohann Richard de Lima
de Moraes, Natália Valadares [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Yamamoto, Priscila Akemi [UNESP]
Benzi, Jhohann Richard de Lima
de Moraes, Natália Valadares [UNESP]
dc.subject.por.fl_str_mv Gabapentin
HPLC
Plasma
Urine
topic Gabapentin
HPLC
Plasma
Urine
description Aim: We aimed to develop methods to determine gabapentin (GAB) in biological samples using high-performance liquid chromatography (HPLC) with application in pharmacokinetics and therapeutic drug monitoring. Methods: Simple, rapid and efficient HPLC-UV methods to quantify GAB in human plasma and urine were developed and validated for clinical analysis of GAB. The 1-fluoro-2,4-dinitrobenzene (FDNB) was used as derivatization agent. For plasma samples, protein precipitation using acetonitrile was performed, before the derivatization reaction. Urine samples were cleaned-up by liquid-liquid extraction with dichloromethane:n-butanol (1:1, v/v) after derivatized. Amlodipine besilate was used as internal standard (IS). Results: Gabapentin and IS were resolved on LiChrospher® C18 RP column and a mixture of 50 mM sodium phosphate buffer (pH 3.9):methanol (27:73, v/v) as mobile phase, at 1.2 mL/min. The methods used small sample volumes, 100 and 50 µL of plasma and urine, respectively. Linearity was obtained in the interval of 0.2-14 µg/mL in plasma and 2-120 µg/mL in urine. Both methods showed to be selective, without carry-over effect, precise, accurate and stable in different conditions. GAB plasma concentration in patients receiving 600 to 3600 mg/day of GAB ranged between 0.40 to 11.94 µg/mL at steady-state. Conclusions: The methods described in this study were simple, rapid and fulfill all validation requirements. They were easily and successfully applied for population pharmacokinetics and therapeutic drug monitoring of GAB in patients with chronic pain.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-25T10:59:31Z
2021-06-25T10:59:31Z
2021-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.4322/2179-443X.0717
Revista de Ciencias Farmaceuticas Basica e Aplicada, v. 42.
2179-443X
1808-4532
http://hdl.handle.net/11449/207701
10.4322/2179-443X.0717
2-s2.0-85105390895
url http://dx.doi.org/10.4322/2179-443X.0717
http://hdl.handle.net/11449/207701
identifier_str_mv Revista de Ciencias Farmaceuticas Basica e Aplicada, v. 42.
2179-443X
1808-4532
10.4322/2179-443X.0717
2-s2.0-85105390895
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Revista de Ciencias Farmaceuticas Basica e Aplicada
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1808128542043537408