Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets

Detalhes bibliográficos
Autor(a) principal: Almeida, Layene Figueiredo [UNESP]
Data de Publicação: 2018
Outros Autores: Martins, Lidia Parsekian [UNESP], Martins, Renato Parsekian [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1007/s00056-018-0146-0
http://hdl.handle.net/11449/164559
Resumo: Purpose To assess the effects of reducing the curing time of a high-power light-emitting diode (LED) unit (Valo, Ultradent, South Jordan, UT, USA) on shear bond strength (SBS) of metal brackets and on the amount of adhesive remnant of two orthodontic composites. Methods Eighty human premolars were divided into four groups (G1-4) according to curing time and composite: G1 (Transbond XT, 6s), G2 (Opal Bond MV, 6s), G3 (Transbond XT, 3s), and G4 (Opal Bond MV, 3s). Twenty-four hours after bonding, brackets were subject to a SBS test performed with a universal testing machine. Enamel surface was analyzed by SEM and the amount of adhesive remnant was assessed by the Image J software area calculation tool. Two-way analysis of variance was used for statistical analysis of SBS data, while Friedman and Mann-Whitney post hoc tests were used to analyze data on the amount of adhesive remnant. Results Time and composite significantly affected SBS (p<0.001). The 6s curing showed a higher SBS value (21.56 MPa) in comparison to 3s curing (15.79 MPa). Transbond XT composite showed a significantly higher SBS value (21.06 MPa) compared to Opal Bond MV (16.29 MPa). After the SBS test, Opal Bond MV showed a significantly greater amount of composite adhered to enamel (p<0.001). Conclusion Reducing exposure time from 6 to 3s significantly decreased mean values of SBS, even with the use of a high-power LED unit. Reduction in time did not affect the amount of adhesive remnant.
id UNSP_f31602b4efd0f1e072097fae67b3036f
oai_identifier_str oai:repositorio.unesp.br:11449/164559
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effects of reducing light-curing time of a high-power LED device on shear bond strength of bracketsLight curing of dental adhesivesOrthodontic bracketsDental bondingDental enamelDental cementsPurpose To assess the effects of reducing the curing time of a high-power light-emitting diode (LED) unit (Valo, Ultradent, South Jordan, UT, USA) on shear bond strength (SBS) of metal brackets and on the amount of adhesive remnant of two orthodontic composites. Methods Eighty human premolars were divided into four groups (G1-4) according to curing time and composite: G1 (Transbond XT, 6s), G2 (Opal Bond MV, 6s), G3 (Transbond XT, 3s), and G4 (Opal Bond MV, 3s). Twenty-four hours after bonding, brackets were subject to a SBS test performed with a universal testing machine. Enamel surface was analyzed by SEM and the amount of adhesive remnant was assessed by the Image J software area calculation tool. Two-way analysis of variance was used for statistical analysis of SBS data, while Friedman and Mann-Whitney post hoc tests were used to analyze data on the amount of adhesive remnant. Results Time and composite significantly affected SBS (p<0.001). The 6s curing showed a higher SBS value (21.56 MPa) in comparison to 3s curing (15.79 MPa). Transbond XT composite showed a significantly higher SBS value (21.06 MPa) compared to Opal Bond MV (16.29 MPa). After the SBS test, Opal Bond MV showed a significantly greater amount of composite adhered to enamel (p<0.001). Conclusion Reducing exposure time from 6 to 3s significantly decreased mean values of SBS, even with the use of a high-power LED unit. Reduction in time did not affect the amount of adhesive remnant.Univ Estadual Paulista, Program Orthodont, Araraquara, BrazilRua Carlos Gomes 2158, BR-14801340 Araraquara, SP, BrazilUniv Estadual Paulista, Program Orthodont, Araraquara, BrazilUrban & VogelUniversidade Estadual Paulista (Unesp)Almeida, Layene Figueiredo [UNESP]Martins, Lidia Parsekian [UNESP]Martins, Renato Parsekian [UNESP]2018-11-26T17:55:02Z2018-11-26T17:55:02Z2018-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article352-358application/pdfhttp://dx.doi.org/10.1007/s00056-018-0146-0Journal Of Orofacial Orthopedics-fortschritte Der Kieferorthopadie. Munich: Urban & Vogel, v. 79, n. 5, p. 352-358, 2018.1434-5293http://hdl.handle.net/11449/16455910.1007/s00056-018-0146-0WOS:000442501200006WOS000442501200006.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal Of Orofacial Orthopedics-fortschritte Der Kieferorthopadie0,579info:eu-repo/semantics/openAccess2024-09-26T14:21:34Zoai:repositorio.unesp.br:11449/164559Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-26T14:21:34Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
title Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
spellingShingle Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
Almeida, Layene Figueiredo [UNESP]
Light curing of dental adhesives
Orthodontic brackets
Dental bonding
Dental enamel
Dental cements
title_short Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
title_full Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
title_fullStr Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
title_full_unstemmed Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
title_sort Effects of reducing light-curing time of a high-power LED device on shear bond strength of brackets
author Almeida, Layene Figueiredo [UNESP]
author_facet Almeida, Layene Figueiredo [UNESP]
Martins, Lidia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
author_role author
author2 Martins, Lidia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
author2_role author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Almeida, Layene Figueiredo [UNESP]
Martins, Lidia Parsekian [UNESP]
Martins, Renato Parsekian [UNESP]
dc.subject.por.fl_str_mv Light curing of dental adhesives
Orthodontic brackets
Dental bonding
Dental enamel
Dental cements
topic Light curing of dental adhesives
Orthodontic brackets
Dental bonding
Dental enamel
Dental cements
description Purpose To assess the effects of reducing the curing time of a high-power light-emitting diode (LED) unit (Valo, Ultradent, South Jordan, UT, USA) on shear bond strength (SBS) of metal brackets and on the amount of adhesive remnant of two orthodontic composites. Methods Eighty human premolars were divided into four groups (G1-4) according to curing time and composite: G1 (Transbond XT, 6s), G2 (Opal Bond MV, 6s), G3 (Transbond XT, 3s), and G4 (Opal Bond MV, 3s). Twenty-four hours after bonding, brackets were subject to a SBS test performed with a universal testing machine. Enamel surface was analyzed by SEM and the amount of adhesive remnant was assessed by the Image J software area calculation tool. Two-way analysis of variance was used for statistical analysis of SBS data, while Friedman and Mann-Whitney post hoc tests were used to analyze data on the amount of adhesive remnant. Results Time and composite significantly affected SBS (p<0.001). The 6s curing showed a higher SBS value (21.56 MPa) in comparison to 3s curing (15.79 MPa). Transbond XT composite showed a significantly higher SBS value (21.06 MPa) compared to Opal Bond MV (16.29 MPa). After the SBS test, Opal Bond MV showed a significantly greater amount of composite adhered to enamel (p<0.001). Conclusion Reducing exposure time from 6 to 3s significantly decreased mean values of SBS, even with the use of a high-power LED unit. Reduction in time did not affect the amount of adhesive remnant.
publishDate 2018
dc.date.none.fl_str_mv 2018-11-26T17:55:02Z
2018-11-26T17:55:02Z
2018-09-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1007/s00056-018-0146-0
Journal Of Orofacial Orthopedics-fortschritte Der Kieferorthopadie. Munich: Urban & Vogel, v. 79, n. 5, p. 352-358, 2018.
1434-5293
http://hdl.handle.net/11449/164559
10.1007/s00056-018-0146-0
WOS:000442501200006
WOS000442501200006.pdf
url http://dx.doi.org/10.1007/s00056-018-0146-0
http://hdl.handle.net/11449/164559
identifier_str_mv Journal Of Orofacial Orthopedics-fortschritte Der Kieferorthopadie. Munich: Urban & Vogel, v. 79, n. 5, p. 352-358, 2018.
1434-5293
10.1007/s00056-018-0146-0
WOS:000442501200006
WOS000442501200006.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal Of Orofacial Orthopedics-fortschritte Der Kieferorthopadie
0,579
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 352-358
application/pdf
dc.publisher.none.fl_str_mv Urban & Vogel
publisher.none.fl_str_mv Urban & Vogel
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv repositoriounesp@unesp.br
_version_ 1813546424071094272