Analysis of mesiodistal angulations of preadjusted brackets
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
DOI: | 10.1590/1807-3107BOR-2014.vol28.0038 |
Texto Completo: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242014000100247&lng=en&nrm=iso&tlng=en http://hdl.handle.net/11449/130252 |
Resumo: | Manufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli) were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01) and between the Forestadent and GAC groups (p < 0.01). For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01) and between the Morelli and Forestadent groups (p < 0.05). In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements. |
id |
UNSP_f6a2937339f93d3c1b98b7768dac2c1d |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/130252 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Analysis of mesiodistal angulations of preadjusted bracketsOrthodontic AppliancesOrthodontic Appliance DesignOrthodontic BracketsManufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli) were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01) and between the Forestadent and GAC groups (p < 0.01). For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01) and between the Morelli and Forestadent groups (p < 0.05). In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements.Univ Estadual Paulista UNESP, Fac Odontol Aracatuba, Dept Pediat &Community Dent, Aracatuba, SP, BrazilUniv Estadual Paulista UNESP, Fac Odontol Aracatuba, Dept Pediat &Community Dent, Aracatuba, SP, BrazilSociedade Brasileira De Pesquisa OdontologicaUniversidade Estadual Paulista (Unesp)Mendonca, Marcos Rogerio de [UNESP]Goncalves Verri, Ana Caroline [UNESP]Fabre, Aubrey Fernando [UNESP]Cuoghi, Osmar Aparecido [UNESP]2015-11-03T15:30:39Z2015-11-03T15:30:39Z2014-09-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article391-398application/pdfhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242014000100247&lng=en&nrm=iso&tlng=enBrazilian Oral Research. Sao Paulo: Sociedade Brasileira De Pesquisa Odontologica, v. 28, n. 5, p. 391-398, 2014.1806-8324http://hdl.handle.net/11449/13025210.1590/1807-3107BOR-2014.vol28.0038S1806-83242014000100247WOS:000348892300010S1806-83242014000100247.pdf8568814008546317Web of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Oral Researchinfo:eu-repo/semantics/openAccess2024-09-19T17:56:14Zoai:repositorio.unesp.br:11449/130252Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462024-09-19T17:56:14Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Analysis of mesiodistal angulations of preadjusted brackets |
title |
Analysis of mesiodistal angulations of preadjusted brackets |
spellingShingle |
Analysis of mesiodistal angulations of preadjusted brackets Analysis of mesiodistal angulations of preadjusted brackets Mendonca, Marcos Rogerio de [UNESP] Orthodontic Appliances Orthodontic Appliance Design Orthodontic Brackets Mendonca, Marcos Rogerio de [UNESP] Orthodontic Appliances Orthodontic Appliance Design Orthodontic Brackets |
title_short |
Analysis of mesiodistal angulations of preadjusted brackets |
title_full |
Analysis of mesiodistal angulations of preadjusted brackets |
title_fullStr |
Analysis of mesiodistal angulations of preadjusted brackets Analysis of mesiodistal angulations of preadjusted brackets |
title_full_unstemmed |
Analysis of mesiodistal angulations of preadjusted brackets Analysis of mesiodistal angulations of preadjusted brackets |
title_sort |
Analysis of mesiodistal angulations of preadjusted brackets |
author |
Mendonca, Marcos Rogerio de [UNESP] |
author_facet |
Mendonca, Marcos Rogerio de [UNESP] Mendonca, Marcos Rogerio de [UNESP] Goncalves Verri, Ana Caroline [UNESP] Fabre, Aubrey Fernando [UNESP] Cuoghi, Osmar Aparecido [UNESP] Goncalves Verri, Ana Caroline [UNESP] Fabre, Aubrey Fernando [UNESP] Cuoghi, Osmar Aparecido [UNESP] |
author_role |
author |
author2 |
Goncalves Verri, Ana Caroline [UNESP] Fabre, Aubrey Fernando [UNESP] Cuoghi, Osmar Aparecido [UNESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Mendonca, Marcos Rogerio de [UNESP] Goncalves Verri, Ana Caroline [UNESP] Fabre, Aubrey Fernando [UNESP] Cuoghi, Osmar Aparecido [UNESP] |
dc.subject.por.fl_str_mv |
Orthodontic Appliances Orthodontic Appliance Design Orthodontic Brackets |
topic |
Orthodontic Appliances Orthodontic Appliance Design Orthodontic Brackets |
description |
Manufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations of Roth prescription preadjusted metallic brackets for the maxillary left central incisor and maxillary left canine. For each tooth type, 10 brackets of three commercial brands (GAC, Forestadent and Morelli) were selected. Two individual metal matrices for brackets and tooth positioning were made for each group of teeth. Captured images were obtained by standardized ortho-radial photography with a digital camera. Images were exported and analyzed with the Image J software package. One-way ANOVA and Tukey statistical analyses were performed at the 5% significance level. For brackets of the maxillary left central incisor, differences in mean angulation were observed between the Morelli and GAC groups (p < 0.01) and between the Forestadent and GAC groups (p < 0.01). For brackets of the maxillary left canine, differences in mean angulation were found between the Morelli and GAC groups (p < 0.01) and between the Morelli and Forestadent groups (p < 0.05). In conclusion, despite their same prescription name, the different brands exhibited significantly different angulation measurements. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-09-01 2015-11-03T15:30:39Z 2015-11-03T15:30:39Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242014000100247&lng=en&nrm=iso&tlng=en Brazilian Oral Research. Sao Paulo: Sociedade Brasileira De Pesquisa Odontologica, v. 28, n. 5, p. 391-398, 2014. 1806-8324 http://hdl.handle.net/11449/130252 10.1590/1807-3107BOR-2014.vol28.0038 S1806-83242014000100247 WOS:000348892300010 S1806-83242014000100247.pdf 8568814008546317 |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242014000100247&lng=en&nrm=iso&tlng=en http://hdl.handle.net/11449/130252 |
identifier_str_mv |
Brazilian Oral Research. Sao Paulo: Sociedade Brasileira De Pesquisa Odontologica, v. 28, n. 5, p. 391-398, 2014. 1806-8324 10.1590/1807-3107BOR-2014.vol28.0038 S1806-83242014000100247 WOS:000348892300010 S1806-83242014000100247.pdf 8568814008546317 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Oral Research |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
391-398 application/pdf |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira De Pesquisa Odontologica |
publisher.none.fl_str_mv |
Sociedade Brasileira De Pesquisa Odontologica |
dc.source.none.fl_str_mv |
Web of Science reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1822183867903115264 |
dc.identifier.doi.none.fl_str_mv |
10.1590/1807-3107BOR-2014.vol28.0038 |