Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial

Detalhes bibliográficos
Autor(a) principal: ALEIXO, Grazielle Anahy de Sousa
Data de Publicação: 2006
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFRPE
Texto Completo: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5673
Resumo: The increase or decrease in the glucose concentration in the blood is a common endocrine alteration in human beings and animals that can cause serious consequences to their health condition. Dosing the glucose of patient with hypo or hyperglycemia allows the same ones to receive appropriate treatment, propitiating a better life quality. The present work had as object to determine the glycemic values of dogs using a portable glucometer (Accu-Chek® Advantage / Roche) projected for human patients, and to compare the results obtained with that equipment to those acquired with the enzymatic-colorimeter (GOD-POD) according to Trinder laboratorial method, since it is considered a standard technique. Once proving that exists a good correlation among the results obtained with the two methods, it becomes possible for the Veterinary Doctors to use the glucometer in their routine with the intention of diagnosing alteration in their patients' glycemia and nevertheless, obtain important information that will help to govern the therapeutic conducts in animals with diseases such as Diabetes mellitus. Another purpose of this work was to describe which factors can alter the precision of the results obtained with the portable glucometer. For the development of the research 53 animals of the canine species, of varied age, sex, weight and breed, assisted at the Veterinary Hospital of the Department of Veterinary Medicine (DMV) of the Rural Federal University of Pernambuco (UFRPE) were used). In 17 patients it was observed factors of risks that could alter the precision of the results in the glucometer, such as low hematocrit, inadequate soak of the test strip, a part of the sample was over the reagent strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer of the equipment, and as consequence, only 36 animals were considered eligible for the study of the evaluation of the portable glucometer in relation to the laboratorial method. It was concluded that the glucose dosage in dogs using the portable glucometer Accu-Chek® Advantage can be considered clinically useful, because the differences obtained among the methods are inside of the margin established by the regulators entities of the area.
id URPE_27ae9975a2f4a505c9768f699218debb
oai_identifier_str oai:tede2:tede2/5673
network_acronym_str URPE
network_name_str Biblioteca Digital de Teses e Dissertações da UFRPE
repository_id_str
spelling COELHO, Maria Cristina de Oliveira CardosoTENÓRIO, Ana Paula MonteiroRÊGO, Eneida WillcoxSANTOS, Rosilda Maria Barretohttp://lattes.cnpq.br/3165940085830406ALEIXO, Grazielle Anahy de Sousa2016-10-11T14:32:01Z2006-03-03ALEIXO, Grazielle Anahy de Sousa. Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial. 2006. 65 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5673The increase or decrease in the glucose concentration in the blood is a common endocrine alteration in human beings and animals that can cause serious consequences to their health condition. Dosing the glucose of patient with hypo or hyperglycemia allows the same ones to receive appropriate treatment, propitiating a better life quality. The present work had as object to determine the glycemic values of dogs using a portable glucometer (Accu-Chek® Advantage / Roche) projected for human patients, and to compare the results obtained with that equipment to those acquired with the enzymatic-colorimeter (GOD-POD) according to Trinder laboratorial method, since it is considered a standard technique. Once proving that exists a good correlation among the results obtained with the two methods, it becomes possible for the Veterinary Doctors to use the glucometer in their routine with the intention of diagnosing alteration in their patients' glycemia and nevertheless, obtain important information that will help to govern the therapeutic conducts in animals with diseases such as Diabetes mellitus. Another purpose of this work was to describe which factors can alter the precision of the results obtained with the portable glucometer. For the development of the research 53 animals of the canine species, of varied age, sex, weight and breed, assisted at the Veterinary Hospital of the Department of Veterinary Medicine (DMV) of the Rural Federal University of Pernambuco (UFRPE) were used). In 17 patients it was observed factors of risks that could alter the precision of the results in the glucometer, such as low hematocrit, inadequate soak of the test strip, a part of the sample was over the reagent strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer of the equipment, and as consequence, only 36 animals were considered eligible for the study of the evaluation of the portable glucometer in relation to the laboratorial method. It was concluded that the glucose dosage in dogs using the portable glucometer Accu-Chek® Advantage can be considered clinically useful, because the differences obtained among the methods are inside of the margin established by the regulators entities of the area.O aumento ou a diminuição da taxa de glicose no sangue é uma alteração endócrina comum em seres humanos e animais, e que pode ocasionar graves conseqüências ao estado de saúde dos mesmos. Dosar a glicose sangüínea de pacientes portadores de hipo ou hiperglicemia permite que eles recebam adequado tratamento, propiciando uma melhor qualidade de vida. O presente trabalho teve como objetivo determinar os valores glicêmicos em cães utilizando um glicosímetro portátil (Accu-Chek® Advantage / Roche Diagnóstica Brasil Ltda.) projetado para pacientes humanos, e comparar os resultados obtidos com esse equipamento àqueles conseguidos com o método laboratorial enzimático-colorimétrico (GOD-POD) segundo Trinder, que é considerado uma técnica padrão. Uma vez comprovada que existe uma boa correlação entre os dois métodos, torna-se possível para os Médicos Veterinários utilizarem o glicosímetro na sua rotina com o intuito de diagnosticar alterações na glicemia de seus pacientes e, ainda assim, obterem informações importantes que vão ajudar a reger as condutas terapêuticas em animUma outra finalidade deste trabalho foi descrever quais fatores de risco podem alterar a precisão dos resultados obtidos com o glicosímetro portátil. Para o desenvolvimento da pesquisa foram utilizados 53 animais da espécie canina, de idades, sexos, pesos e raças variadas, atendidos no Hospital Veterinário do Departamento de Medicina Veterinária (DMV) da Universidade Federal Rural de Pernambuco (UFRPE). Em 17 pacientes foram observados fatores que poderiam alterar a precisão dos resultados no glicosímetro, como baixo hematócrito, embebição inadequada da tira teste, uma parte da amostra ficou por cima da tira reagente ou ainda, a realização do teste ultrapassou os 15 segundos recomendados pelo fabricante do equipamento e, como conseqüência, apenas 36 animais foram considerados elegíveis para o estudo da avaliação do glicosímetro portátil em relação ao método laboratorial. Concluiu-se que a dosagem de glicose em cães utilizando o glicosímetro portátil Accu-Chek® Advantage pode ser considerada clinicamente útil, pois as diferenças obtidas entre os métodos estão dentro da margem estabelecida pelos órgãos reguladores da área.Submitted by (edna.saturno@ufrpe.br) on 2016-10-11T14:32:01Z No. of bitstreams: 1 Graziele Anahy de Sousa Aleixo.pdf: 843230 bytes, checksum: 901bb6f90c73356f618d782d2e601a75 (MD5)Made available in DSpace on 2016-10-11T14:32:01Z (GMT). No. of bitstreams: 1 Graziele Anahy de Sousa Aleixo.pdf: 843230 bytes, checksum: 901bb6f90c73356f618d782d2e601a75 (MD5) Previous issue date: 2006-03-03Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfporUniversidade Federal Rural de PernambucoPrograma de Pós-Graduação em Ciência VeterináriaUFRPEBrasilDepartamento de Medicina VeterináriaCãoGlicemiaHipoglicemiaHiperglicemiaDogHyperglycemiaGlycemiaHypoglycemiaCIENCIAS AGRARIAS::MEDICINA VETERINARIAComparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorialinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-3061482854177903105600600600600-30202105637636167804536702642350173192075167498588264571info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UFRPEinstname:Universidade Federal Rural de Pernambuco (UFRPE)instacron:UFRPELICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/5673/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51ORIGINALGraziele Anahy de Sousa Aleixo.pdfGraziele Anahy de Sousa Aleixo.pdfapplication/pdf843230http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/5673/2/Graziele+Anahy+de+Sousa+Aleixo.pdf901bb6f90c73356f618d782d2e601a75MD52tede2/56732016-10-11 11:32:01.135oai:tede2: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Biblioteca Digital de Teses e Dissertaçõeshttp://www.tede2.ufrpe.br:8080/tede/PUBhttp://www.tede2.ufrpe.br:8080/oai/requestbdtd@ufrpe.br ||bdtd@ufrpe.bropendoar:2024-05-28T12:33:22.417270Biblioteca Digital de Teses e Dissertações da UFRPE - Universidade Federal Rural de Pernambuco (UFRPE)false
dc.title.por.fl_str_mv Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
title Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
spellingShingle Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
ALEIXO, Grazielle Anahy de Sousa
Cão
Glicemia
Hipoglicemia
Hiperglicemia
Dog
Hyperglycemia
Glycemia
Hypoglycemia
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
title_short Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
title_full Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
title_fullStr Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
title_full_unstemmed Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
title_sort Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial
author ALEIXO, Grazielle Anahy de Sousa
author_facet ALEIXO, Grazielle Anahy de Sousa
author_role author
dc.contributor.advisor1.fl_str_mv COELHO, Maria Cristina de Oliveira Cardoso
dc.contributor.referee1.fl_str_mv TENÓRIO, Ana Paula Monteiro
dc.contributor.referee2.fl_str_mv RÊGO, Eneida Willcox
dc.contributor.referee3.fl_str_mv SANTOS, Rosilda Maria Barreto
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/3165940085830406
dc.contributor.author.fl_str_mv ALEIXO, Grazielle Anahy de Sousa
contributor_str_mv COELHO, Maria Cristina de Oliveira Cardoso
TENÓRIO, Ana Paula Monteiro
RÊGO, Eneida Willcox
SANTOS, Rosilda Maria Barreto
dc.subject.por.fl_str_mv Cão
Glicemia
topic Cão
Glicemia
Hipoglicemia
Hiperglicemia
Dog
Hyperglycemia
Glycemia
Hypoglycemia
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
dc.subject.eng.fl_str_mv Hipoglicemia
Hiperglicemia
Dog
Hyperglycemia
Glycemia
Hypoglycemia
dc.subject.cnpq.fl_str_mv CIENCIAS AGRARIAS::MEDICINA VETERINARIA
description The increase or decrease in the glucose concentration in the blood is a common endocrine alteration in human beings and animals that can cause serious consequences to their health condition. Dosing the glucose of patient with hypo or hyperglycemia allows the same ones to receive appropriate treatment, propitiating a better life quality. The present work had as object to determine the glycemic values of dogs using a portable glucometer (Accu-Chek® Advantage / Roche) projected for human patients, and to compare the results obtained with that equipment to those acquired with the enzymatic-colorimeter (GOD-POD) according to Trinder laboratorial method, since it is considered a standard technique. Once proving that exists a good correlation among the results obtained with the two methods, it becomes possible for the Veterinary Doctors to use the glucometer in their routine with the intention of diagnosing alteration in their patients' glycemia and nevertheless, obtain important information that will help to govern the therapeutic conducts in animals with diseases such as Diabetes mellitus. Another purpose of this work was to describe which factors can alter the precision of the results obtained with the portable glucometer. For the development of the research 53 animals of the canine species, of varied age, sex, weight and breed, assisted at the Veterinary Hospital of the Department of Veterinary Medicine (DMV) of the Rural Federal University of Pernambuco (UFRPE) were used). In 17 patients it was observed factors of risks that could alter the precision of the results in the glucometer, such as low hematocrit, inadequate soak of the test strip, a part of the sample was over the reagent strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer of the equipment, and as consequence, only 36 animals were considered eligible for the study of the evaluation of the portable glucometer in relation to the laboratorial method. It was concluded that the glucose dosage in dogs using the portable glucometer Accu-Chek® Advantage can be considered clinically useful, because the differences obtained among the methods are inside of the margin established by the regulators entities of the area.
publishDate 2006
dc.date.issued.fl_str_mv 2006-03-03
dc.date.accessioned.fl_str_mv 2016-10-11T14:32:01Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ALEIXO, Grazielle Anahy de Sousa. Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial. 2006. 65 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.
dc.identifier.uri.fl_str_mv http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5673
identifier_str_mv ALEIXO, Grazielle Anahy de Sousa. Comparação da glicemia em cães utilizando o glicosímetro portátil e o método de referência laboratorial. 2006. 65 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.
url http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/5673
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -3061482854177903105
dc.relation.confidence.fl_str_mv 600
600
600
600
dc.relation.department.fl_str_mv -3020210563763616780
dc.relation.cnpq.fl_str_mv 453670264235017319
dc.relation.sponsorship.fl_str_mv 2075167498588264571
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal Rural de Pernambuco
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Ciência Veterinária
dc.publisher.initials.fl_str_mv UFRPE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Departamento de Medicina Veterinária
publisher.none.fl_str_mv Universidade Federal Rural de Pernambuco
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFRPE
instname:Universidade Federal Rural de Pernambuco (UFRPE)
instacron:UFRPE
instname_str Universidade Federal Rural de Pernambuco (UFRPE)
instacron_str UFRPE
institution UFRPE
reponame_str Biblioteca Digital de Teses e Dissertações da UFRPE
collection Biblioteca Digital de Teses e Dissertações da UFRPE
bitstream.url.fl_str_mv http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/5673/1/license.txt
http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/5673/2/Graziele+Anahy+de+Sousa+Aleixo.pdf
bitstream.checksum.fl_str_mv bd3efa91386c1718a7f26a329fdcb468
901bb6f90c73356f618d782d2e601a75
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UFRPE - Universidade Federal Rural de Pernambuco (UFRPE)
repository.mail.fl_str_mv bdtd@ufrpe.br ||bdtd@ufrpe.br
_version_ 1810102228324712448