Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva

Detalhes bibliográficos
Autor(a) principal: SANTOS, Breno Menezes dos
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFRPE
Texto Completo: http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/7513
Resumo: The electrocardiogram (ECG) is a sensitive and specific technique for the identification and classification of cardiac arrhythmias. In addition, the ECG may also suggest increased cardiac chambers, rhythm monitoring during surgeries and chemical restraint, diagnostic aid for structural heart disease, electrolyte disturbances, metabolic diseases, and pericardial effusion. Although it is a diagnostic technique already established in the veterinary routine, it is necessary studies that characterize some of its variables, in view of the scarcity of scientific material addressing this subject specifically in felines of company. In this context, the present study aimed to evaluate the electrocardiogram and to standardize the precordial leads in domestic cats for elective gonadectomy. Eighty healthy and adult animals with surgical indication for elective gonadectomy, from the clinical care routine performed at University Veterinary Hospital -UAG (UFRPE), were evaluated. The electrocardiogram was performed using the computerized method, with standardized equipment at sensitivity 1cm = 1mv and velocity of 50mm / s. The results obtained expressed as mean and standard deviation were HR: 194.20 ± 31.48 (bpm); P wave: 0.04 ± 0.00 (s) X 0.11 ± 0.03 (mV); PR interval: 0.07 ± 0.01 (s); QRS complex: 0.04 ± 0.00 (s) X 0.34 ± 0.21 (mV); QT interval: 0.16 ± 0.02 (s); T wave 0.14 ± 0.07 (mV); R wave (rV2): 0.17 ± 0.10 (mV); S wave (rV2): 0.12 ± 0.10 (mV); R wave (V2): 0.30 ± 0.21 (mV); S wave (V2): 0.10 ± 0.11 (mV); R wave (V4): 0.22 ± 0.21 (mV); S wave (V4): 0.03 ± 0.07 (mV); RC: sinus rhythm (92.5%), ST segment: isoelectric (92.5%), electric axis: 91.5% (within normal range); polarity of the T wave (rV2): positive (82.5%), polarity of the T wave (V2): positive (95%); polarity of the T wave (V4): positive (93.7%), polarity of the T wave (V10): negative (87.5%). It was verified that the electrocardiographic changes present in the preoperative examination of healthy cats present a significant frequency and that the majority of the evaluated animals present positive T-wave polarity in the pre-cordial leads rV2, V2 and V4, and negative in V10. It was also concluded that all animals evaluated had R-waves smaller than 0.5 mV in the rV2 lead, and S-waves smaller than 0.5 mV in leads rV2, V2 and V4, raising a probable hypothesis that said waves in these leads should be less than this value in domestic felines.
id URPE_68351a0c6eb89603bc74ed589d33dc4d
oai_identifier_str oai:tede2:tede2/7513
network_acronym_str URPE
network_name_str Biblioteca Digital de Teses e Dissertações da UFRPE
repository_id_str
spelling OLIVEIRA, Marcos Antonio Lemos deFREITAS, Aderaldo Alexandrino deOLIVEIRA, Marcos Antonio de LemosLIMA, Evilda Rodrigues deFERRI, Rinaldo Cavalcantehttp://lattes.cnpq.br/9243036468165681SANTOS, Breno Menezes dos2018-09-04T15:43:37Z2018-02-28SANTOS, Breno Menezes dos. Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva. 2018. 73 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/7513The electrocardiogram (ECG) is a sensitive and specific technique for the identification and classification of cardiac arrhythmias. In addition, the ECG may also suggest increased cardiac chambers, rhythm monitoring during surgeries and chemical restraint, diagnostic aid for structural heart disease, electrolyte disturbances, metabolic diseases, and pericardial effusion. Although it is a diagnostic technique already established in the veterinary routine, it is necessary studies that characterize some of its variables, in view of the scarcity of scientific material addressing this subject specifically in felines of company. In this context, the present study aimed to evaluate the electrocardiogram and to standardize the precordial leads in domestic cats for elective gonadectomy. Eighty healthy and adult animals with surgical indication for elective gonadectomy, from the clinical care routine performed at University Veterinary Hospital -UAG (UFRPE), were evaluated. The electrocardiogram was performed using the computerized method, with standardized equipment at sensitivity 1cm = 1mv and velocity of 50mm / s. The results obtained expressed as mean and standard deviation were HR: 194.20 ± 31.48 (bpm); P wave: 0.04 ± 0.00 (s) X 0.11 ± 0.03 (mV); PR interval: 0.07 ± 0.01 (s); QRS complex: 0.04 ± 0.00 (s) X 0.34 ± 0.21 (mV); QT interval: 0.16 ± 0.02 (s); T wave 0.14 ± 0.07 (mV); R wave (rV2): 0.17 ± 0.10 (mV); S wave (rV2): 0.12 ± 0.10 (mV); R wave (V2): 0.30 ± 0.21 (mV); S wave (V2): 0.10 ± 0.11 (mV); R wave (V4): 0.22 ± 0.21 (mV); S wave (V4): 0.03 ± 0.07 (mV); RC: sinus rhythm (92.5%), ST segment: isoelectric (92.5%), electric axis: 91.5% (within normal range); polarity of the T wave (rV2): positive (82.5%), polarity of the T wave (V2): positive (95%); polarity of the T wave (V4): positive (93.7%), polarity of the T wave (V10): negative (87.5%). It was verified that the electrocardiographic changes present in the preoperative examination of healthy cats present a significant frequency and that the majority of the evaluated animals present positive T-wave polarity in the pre-cordial leads rV2, V2 and V4, and negative in V10. It was also concluded that all animals evaluated had R-waves smaller than 0.5 mV in the rV2 lead, and S-waves smaller than 0.5 mV in leads rV2, V2 and V4, raising a probable hypothesis that said waves in these leads should be less than this value in domestic felines.O eletrocardiograma (ECG) é uma técnica sensível e específica para a identificação e classificação das arritmias cardíacas. Além disso, o ECG também pode sugerir aumento de câmaras cardíacas, monitoramento do ritmo durante cirurgias e contenção química, auxílio diagnóstico para cardiopatias estruturais, distúrbios eletrolíticos, doenças metabólicas, além de efusão pericárdica. Apesar de ser uma técnica diagnóstica já estabelecida na rotina veterinária, torna-se necessário estudos que padronizem algumas de suas variáveis, em vista da escassez de material científico abordando esse tema especificamente em felinos de companhia. Dentro desse contexto, o presente estudo teve como objetivo avaliar o eletrocardiograma e caracterizar as derivações precordiais em gatos domésticos destinados a gonadectomia eletiva. Foram avaliados 80 animais adultos e saudáveis com indicação cirúrgica para gonadectomia eletiva, provenientes da rotina de atendimento clínico realizado no Hospital Veterinário Universitário -UAG (UFRPE). O eletrocardiograma foi realizado por meio do método computadorizado, com equipamento padronizado na sensibilidade 1cm =1mv e velocidade de 50mm/s. Os resultados obtidos expressos em média e desvio padrão foram FC: 194,20 ± 31,48(bpm); onda P: 0,04 ± 0,00 (s) X 0,11 ± 0,03 (mV); intervalo PR: 0,07 ± 0,01 (s); complexo QRS: 0,04 ± 0,00 (s) X 0,34 ± 0,21 (mV); intervalo QT: 0,16 ± 0,02 (s); onda T 0,14 ± 0,07 (mV); onda R (rV2): 0,17 ± 0,10 (mV); onda S (rV2): 0,12 ± 0,10 (mV); onda R (V2): 0,30 ± 0,21 (mV); onda S (V2): 0,10 ± 0,11 (mV); onda R (V4): 0,22 ± 0,21(mV); onda S (V4): 0,03 ± 0,07 (mV); RC: ritmo sinusal (92,5%), segmento ST: isoelétrico (92,5%), eixo elétrico: 91,5% (dentro da normalidade); polaridade da onda T (rV2): positiva (82,5%), polaridade da onda T (V2): positiva (95%); polaridade da onda T (V4): positiva (93,7%), polaridade da onda T (V10): negativa (87,5%). Verificou-se que as alterações eletrocardiográficas presentes no exame pré operatório de felinos saudáveis apresentam frequência significativa e que a maioria dos animais avaliados apresentam polaridade da onda T positiva nas derivações pré cordiais rV2, V2 e V4, e negativa em V10. Conclui-se também que todos animais avaliados apresentaram ondas R menores que 0,5 mV na derivação rV2, e ondas S menores que 0,5 mV nas derivações rV2, V2 e V4, levantando uma hipótese provável, que as referidas ondas nestas derivações devem ser menores que este valor em felinos domésticos.Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-09-04T15:43:37Z No. of bitstreams: 1 Breno Menezes dos Santos.pdf: 9877941 bytes, checksum: 1b8d20328a444f653babae80e8afea97 (MD5)Made available in DSpace on 2018-09-04T15:43:37Z (GMT). No. of bitstreams: 1 Breno Menezes dos Santos.pdf: 9877941 bytes, checksum: 1b8d20328a444f653babae80e8afea97 (MD5) Previous issue date: 2018-02-28application/pdfporUniversidade Federal Rural de PernambucoPrograma de Pós-Graduação em Ciência VeterináriaUFRPEBrasilDepartamento de Medicina VeterináriaEletrocardiogramaGonadectomia eletivaGatoCIENCIAS AGRARIAS::MEDICINA VETERINARIAAvaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletivainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis-3061482854177903105600600600-3020210563763616780453670264235017319info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UFRPEinstname:Universidade Federal Rural de Pernambuco (UFRPE)instacron:UFRPEORIGINALBreno Menezes dos Santos.pdfBreno Menezes dos Santos.pdfapplication/pdf9877941http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/7513/2/Breno+Menezes+dos+Santos.pdf1b8d20328a444f653babae80e8afea97MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/7513/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede2/75132018-09-04 12:43:37.103oai:tede2: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Biblioteca Digital de Teses e Dissertaçõeshttp://www.tede2.ufrpe.br:8080/tede/PUBhttp://www.tede2.ufrpe.br:8080/oai/requestbdtd@ufrpe.br ||bdtd@ufrpe.bropendoar:2024-05-28T12:35:47.073467Biblioteca Digital de Teses e Dissertações da UFRPE - Universidade Federal Rural de Pernambuco (UFRPE)false
dc.title.por.fl_str_mv Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
title Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
spellingShingle Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
SANTOS, Breno Menezes dos
Eletrocardiograma
Gonadectomia eletiva
Gato
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
title_short Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
title_full Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
title_fullStr Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
title_full_unstemmed Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
title_sort Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva
author SANTOS, Breno Menezes dos
author_facet SANTOS, Breno Menezes dos
author_role author
dc.contributor.advisor1.fl_str_mv OLIVEIRA, Marcos Antonio Lemos de
dc.contributor.advisor-co1.fl_str_mv FREITAS, Aderaldo Alexandrino de
dc.contributor.referee1.fl_str_mv OLIVEIRA, Marcos Antonio de Lemos
dc.contributor.referee2.fl_str_mv LIMA, Evilda Rodrigues de
dc.contributor.referee3.fl_str_mv FERRI, Rinaldo Cavalcante
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9243036468165681
dc.contributor.author.fl_str_mv SANTOS, Breno Menezes dos
contributor_str_mv OLIVEIRA, Marcos Antonio Lemos de
FREITAS, Aderaldo Alexandrino de
OLIVEIRA, Marcos Antonio de Lemos
LIMA, Evilda Rodrigues de
FERRI, Rinaldo Cavalcante
dc.subject.por.fl_str_mv Eletrocardiograma
Gonadectomia eletiva
Gato
topic Eletrocardiograma
Gonadectomia eletiva
Gato
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
dc.subject.cnpq.fl_str_mv CIENCIAS AGRARIAS::MEDICINA VETERINARIA
description The electrocardiogram (ECG) is a sensitive and specific technique for the identification and classification of cardiac arrhythmias. In addition, the ECG may also suggest increased cardiac chambers, rhythm monitoring during surgeries and chemical restraint, diagnostic aid for structural heart disease, electrolyte disturbances, metabolic diseases, and pericardial effusion. Although it is a diagnostic technique already established in the veterinary routine, it is necessary studies that characterize some of its variables, in view of the scarcity of scientific material addressing this subject specifically in felines of company. In this context, the present study aimed to evaluate the electrocardiogram and to standardize the precordial leads in domestic cats for elective gonadectomy. Eighty healthy and adult animals with surgical indication for elective gonadectomy, from the clinical care routine performed at University Veterinary Hospital -UAG (UFRPE), were evaluated. The electrocardiogram was performed using the computerized method, with standardized equipment at sensitivity 1cm = 1mv and velocity of 50mm / s. The results obtained expressed as mean and standard deviation were HR: 194.20 ± 31.48 (bpm); P wave: 0.04 ± 0.00 (s) X 0.11 ± 0.03 (mV); PR interval: 0.07 ± 0.01 (s); QRS complex: 0.04 ± 0.00 (s) X 0.34 ± 0.21 (mV); QT interval: 0.16 ± 0.02 (s); T wave 0.14 ± 0.07 (mV); R wave (rV2): 0.17 ± 0.10 (mV); S wave (rV2): 0.12 ± 0.10 (mV); R wave (V2): 0.30 ± 0.21 (mV); S wave (V2): 0.10 ± 0.11 (mV); R wave (V4): 0.22 ± 0.21 (mV); S wave (V4): 0.03 ± 0.07 (mV); RC: sinus rhythm (92.5%), ST segment: isoelectric (92.5%), electric axis: 91.5% (within normal range); polarity of the T wave (rV2): positive (82.5%), polarity of the T wave (V2): positive (95%); polarity of the T wave (V4): positive (93.7%), polarity of the T wave (V10): negative (87.5%). It was verified that the electrocardiographic changes present in the preoperative examination of healthy cats present a significant frequency and that the majority of the evaluated animals present positive T-wave polarity in the pre-cordial leads rV2, V2 and V4, and negative in V10. It was also concluded that all animals evaluated had R-waves smaller than 0.5 mV in the rV2 lead, and S-waves smaller than 0.5 mV in leads rV2, V2 and V4, raising a probable hypothesis that said waves in these leads should be less than this value in domestic felines.
publishDate 2018
dc.date.accessioned.fl_str_mv 2018-09-04T15:43:37Z
dc.date.issued.fl_str_mv 2018-02-28
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SANTOS, Breno Menezes dos. Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva. 2018. 73 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.
dc.identifier.uri.fl_str_mv http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/7513
identifier_str_mv SANTOS, Breno Menezes dos. Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva. 2018. 73 f. Dissertação (Programa de Pós-Graduação em Ciência Veterinária) - Universidade Federal Rural de Pernambuco, Recife.
url http://www.tede2.ufrpe.br:8080/tede2/handle/tede2/7513
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -3061482854177903105
dc.relation.confidence.fl_str_mv 600
600
600
dc.relation.department.fl_str_mv -3020210563763616780
dc.relation.cnpq.fl_str_mv 453670264235017319
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal Rural de Pernambuco
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Ciência Veterinária
dc.publisher.initials.fl_str_mv UFRPE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Departamento de Medicina Veterinária
publisher.none.fl_str_mv Universidade Federal Rural de Pernambuco
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFRPE
instname:Universidade Federal Rural de Pernambuco (UFRPE)
instacron:UFRPE
instname_str Universidade Federal Rural de Pernambuco (UFRPE)
instacron_str UFRPE
institution UFRPE
reponame_str Biblioteca Digital de Teses e Dissertações da UFRPE
collection Biblioteca Digital de Teses e Dissertações da UFRPE
bitstream.url.fl_str_mv http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/7513/2/Breno+Menezes+dos+Santos.pdf
http://www.tede2.ufrpe.br:8080/tede2/bitstream/tede2/7513/1/license.txt
bitstream.checksum.fl_str_mv 1b8d20328a444f653babae80e8afea97
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UFRPE - Universidade Federal Rural de Pernambuco (UFRPE)
repository.mail.fl_str_mv bdtd@ufrpe.br ||bdtd@ufrpe.br
_version_ 1810102251494047744