Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | https://www.revistas.usp.br/jaos/article/view/3790 |
Resumo: | OBJECTIVES: The aim of this study was to investigate the bond strength of ceramic restorations luted using a self-adhesive resin cement (RelyX Unicem, 3M ESPE) under different dentin conditions. MATERIAL AND METHODS: In the experimental groups, ceramic restorations were luted to bovine incisors with RelyX Unicem under the following conditions: [Dry dentin]: surface was dried using air stream for 15 s; [Moist dentin]: excess dentin moisture was removed with absorbent paper; [Bonding agent]: Clearfil SE Bond (Kuraray) self-etching adhesive system was previously applied to dentin. In the Control group, cementation was done using an etch-and-rinse adhesive (Excite DSC) and Variolink II resin cement (Ivoclar Vivadent). Photoactivation of the resin cements was performed with UltraLume LED 5 unit (Ultradent). The restorations (n=5 per group) were sectioned into beams and microtensile testing was carried out. Data were subjected to ANOVA and Tukey's test (p |
id |
USP-17_2d6653a25e6a3c1efa2582ca8e6afbf0 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/3790 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions Dental bondingDental cementsDental porcelainTensile strength OBJECTIVES: The aim of this study was to investigate the bond strength of ceramic restorations luted using a self-adhesive resin cement (RelyX Unicem, 3M ESPE) under different dentin conditions. MATERIAL AND METHODS: In the experimental groups, ceramic restorations were luted to bovine incisors with RelyX Unicem under the following conditions: [Dry dentin]: surface was dried using air stream for 15 s; [Moist dentin]: excess dentin moisture was removed with absorbent paper; [Bonding agent]: Clearfil SE Bond (Kuraray) self-etching adhesive system was previously applied to dentin. In the Control group, cementation was done using an etch-and-rinse adhesive (Excite DSC) and Variolink II resin cement (Ivoclar Vivadent). Photoactivation of the resin cements was performed with UltraLume LED 5 unit (Ultradent). The restorations (n=5 per group) were sectioned into beams and microtensile testing was carried out. Data were subjected to ANOVA and Tukey's test (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2010-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/379010.1590/S1678-77572010000300008Journal of Applied Oral Science; Vol. 18 No. 3 (2010); 244-248 Journal of Applied Oral Science; Vol. 18 Núm. 3 (2010); 244-248 Journal of Applied Oral Science; v. 18 n. 3 (2010); 244-248 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3790/4480Copyright (c) 2010 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessGuarda, Guilherme BGonçalves, Luciano SCorrer, Américo BMoraes, Rafael RSinhoreti, Mário A.CCorrer-Sobrinho, Lourenço2012-04-27T12:09:14Zoai:revistas.usp.br:article/3790Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T12:09:14Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
title |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
spellingShingle |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions Guarda, Guilherme B Dental bonding Dental cements Dental porcelain Tensile strength |
title_short |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
title_full |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
title_fullStr |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
title_full_unstemmed |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
title_sort |
Luting glass ceramic restorations using a self-adhesive resin cement under different dentin conditions |
author |
Guarda, Guilherme B |
author_facet |
Guarda, Guilherme B Gonçalves, Luciano S Correr, Américo B Moraes, Rafael R Sinhoreti, Mário A.C Correr-Sobrinho, Lourenço |
author_role |
author |
author2 |
Gonçalves, Luciano S Correr, Américo B Moraes, Rafael R Sinhoreti, Mário A.C Correr-Sobrinho, Lourenço |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Guarda, Guilherme B Gonçalves, Luciano S Correr, Américo B Moraes, Rafael R Sinhoreti, Mário A.C Correr-Sobrinho, Lourenço |
dc.subject.por.fl_str_mv |
Dental bonding Dental cements Dental porcelain Tensile strength |
topic |
Dental bonding Dental cements Dental porcelain Tensile strength |
description |
OBJECTIVES: The aim of this study was to investigate the bond strength of ceramic restorations luted using a self-adhesive resin cement (RelyX Unicem, 3M ESPE) under different dentin conditions. MATERIAL AND METHODS: In the experimental groups, ceramic restorations were luted to bovine incisors with RelyX Unicem under the following conditions: [Dry dentin]: surface was dried using air stream for 15 s; [Moist dentin]: excess dentin moisture was removed with absorbent paper; [Bonding agent]: Clearfil SE Bond (Kuraray) self-etching adhesive system was previously applied to dentin. In the Control group, cementation was done using an etch-and-rinse adhesive (Excite DSC) and Variolink II resin cement (Ivoclar Vivadent). Photoactivation of the resin cements was performed with UltraLume LED 5 unit (Ultradent). The restorations (n=5 per group) were sectioned into beams and microtensile testing was carried out. Data were subjected to ANOVA and Tukey's test (p |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3790 10.1590/S1678-77572010000300008 |
url |
https://www.revistas.usp.br/jaos/article/view/3790 |
identifier_str_mv |
10.1590/S1678-77572010000300008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/jaos/article/view/3790/4480 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2010 Journal of Applied Oral Science info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2010 Journal of Applied Oral Science |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
publisher.none.fl_str_mv |
Universidade de São Paulo. Faculdade de Odontologia de Bauru |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science; Vol. 18 No. 3 (2010); 244-248 Journal of Applied Oral Science; Vol. 18 Núm. 3 (2010); 244-248 Journal of Applied Oral Science; v. 18 n. 3 (2010); 244-248 1678-7765 1678-7757 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1800221675475697664 |