Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins

Detalhes bibliográficos
Autor(a) principal: Souza Júnior,Joane Augusto de
Data de Publicação: 2006
Outros Autores: Garcia,Renata Cunha Matheus Rodrigues, Moura,Juliana Silva, Del Bel Cury,Altair Antoninha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300012
Resumo: Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-µm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm²) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 µm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p<0.05) for roughness and Knoop hardness, with light-polymerized resin presenting the highest values (Ra = 0.11 µm and hardness between 20.2 and 21.4 Kg/mm²). Knoop values at different distances from the metal bar did not differ statistically (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.
id USP-17_53f37af045fedf61a6f8a127b0f0d15a
oai_identifier_str oai:scielo:S1678-77572006000300012
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resinsLight-polymerized acrylic resinSurface roughnessSurface hardnessAlthough visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-µm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm²) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 µm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p<0.05) for roughness and Knoop hardness, with light-polymerized resin presenting the highest values (Ra = 0.11 µm and hardness between 20.2 and 21.4 Kg/mm²). Knoop values at different distances from the metal bar did not differ statistically (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.Faculdade De Odontologia De Bauru - USP2006-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300012Journal of Applied Oral Science v.14 n.3 2006reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572006000300012info:eu-repo/semantics/openAccessSouza Júnior,Joane Augusto deGarcia,Renata Cunha Matheus RodriguesMoura,Juliana SilvaDel Bel Cury,Altair Antoninhaeng2006-08-14T00:00:00Zoai:scielo:S1678-77572006000300012Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2006-08-14T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
title Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
spellingShingle Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
Souza Júnior,Joane Augusto de
Light-polymerized acrylic resin
Surface roughness
Surface hardness
title_short Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
title_full Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
title_fullStr Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
title_full_unstemmed Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
title_sort Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins
author Souza Júnior,Joane Augusto de
author_facet Souza Júnior,Joane Augusto de
Garcia,Renata Cunha Matheus Rodrigues
Moura,Juliana Silva
Del Bel Cury,Altair Antoninha
author_role author
author2 Garcia,Renata Cunha Matheus Rodrigues
Moura,Juliana Silva
Del Bel Cury,Altair Antoninha
author2_role author
author
author
dc.contributor.author.fl_str_mv Souza Júnior,Joane Augusto de
Garcia,Renata Cunha Matheus Rodrigues
Moura,Juliana Silva
Del Bel Cury,Altair Antoninha
dc.subject.por.fl_str_mv Light-polymerized acrylic resin
Surface roughness
Surface hardness
topic Light-polymerized acrylic resin
Surface roughness
Surface hardness
description Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-µm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm²) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 µm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p<0.05) for roughness and Knoop hardness, with light-polymerized resin presenting the highest values (Ra = 0.11 µm and hardness between 20.2 and 21.4 Kg/mm²). Knoop values at different distances from the metal bar did not differ statistically (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.
publishDate 2006
dc.date.none.fl_str_mv 2006-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-77572006000300012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.14 n.3 2006
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936434290524160