Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial

Detalhes bibliográficos
Autor(a) principal: Alhaija, Elham S. Abu
Data de Publicação: 2021
Outros Autores: Shahin, Ahmad Y., Badran, Serene A., Daher, Saba O., Daher, Hasan O.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/191418
Resumo: Optimal orthodontic force results in maximum rate of tooth movement without tissue damage. Even though starting orthodontic treatment with a thicker archwire may shorten treatment duration, the evidence on the effect of using 0.018-inch NiTi as the first alignment archwire on pulpal blood flow (PBF) status is still scarce. Objectives: to record PBF changes and pain scores associated with using 0.018-inch NiTi as the first alignment archwire during fixed orthodontic treatment. Methodology: Patients were selected from subjects attending postgraduate orthodontic teaching clinics at Jordan University of Science and Technology. In total, forty healthy patients who exhibited mild lower arch crowding were included. A split-mouth trial design was used. Each patient received two archwire sizes at one time joined in the midline by crimpable hook and applied in the lower arch. Patients were assigned into one of two groups based on archwire sizes used. Group 1: 0.014-inch and 0.018-inch NiTi (Six males, 14 females aged 19.4±1.33 years) and Group 2: 0.016-inch and 0.018-inch NiTi (Seven males, 13 females aged 19.6±1.45 years). The archwire size group was randomly allocated with a 1:1 allocation ratio. A Laser Doppler Flowmeter was used to measure PBF at different time intervals (T0-T5). Pain scores were recorded using a visual analogue scale (VAS). A repeated measures ANOVA and a post-hoc Bonferroni comparison tests were conducted to examine differences at the different time points before and during orthodontic alignment. Results: For all studied archwire sizes, PBF decreased 20 minutes after their placement. Most PBF changes occurred within 24hours and continued to decrease until 72 hours after archwire placement where the maximum reduction was reached. Eventually, normal values were reverted within 1 month. PBF changes were similar between all alignment – groups. Conclusions: Initial orthodontic alignment with 0.018-inch NiTi does not cause irreversible changes to pulpal vasculature or produces higher pain scores.
id USP-17_5ddb6c1ba0f4b1c5c22ba52fe1c592f0
oai_identifier_str oai:revistas.usp.br:article/191418
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trialFixed applianceLaser Doppler FlowmeterPainArchwireAlignmentOptimal orthodontic force results in maximum rate of tooth movement without tissue damage. Even though starting orthodontic treatment with a thicker archwire may shorten treatment duration, the evidence on the effect of using 0.018-inch NiTi as the first alignment archwire on pulpal blood flow (PBF) status is still scarce. Objectives: to record PBF changes and pain scores associated with using 0.018-inch NiTi as the first alignment archwire during fixed orthodontic treatment. Methodology: Patients were selected from subjects attending postgraduate orthodontic teaching clinics at Jordan University of Science and Technology. In total, forty healthy patients who exhibited mild lower arch crowding were included. A split-mouth trial design was used. Each patient received two archwire sizes at one time joined in the midline by crimpable hook and applied in the lower arch. Patients were assigned into one of two groups based on archwire sizes used. Group 1: 0.014-inch and 0.018-inch NiTi (Six males, 14 females aged 19.4±1.33 years) and Group 2: 0.016-inch and 0.018-inch NiTi (Seven males, 13 females aged 19.6±1.45 years). The archwire size group was randomly allocated with a 1:1 allocation ratio. A Laser Doppler Flowmeter was used to measure PBF at different time intervals (T0-T5). Pain scores were recorded using a visual analogue scale (VAS). A repeated measures ANOVA and a post-hoc Bonferroni comparison tests were conducted to examine differences at the different time points before and during orthodontic alignment. Results: For all studied archwire sizes, PBF decreased 20 minutes after their placement. Most PBF changes occurred within 24hours and continued to decrease until 72 hours after archwire placement where the maximum reduction was reached. Eventually, normal values were reverted within 1 month. PBF changes were similar between all alignment – groups. Conclusions: Initial orthodontic alignment with 0.018-inch NiTi does not cause irreversible changes to pulpal vasculature or produces higher pain scores.Universidade de São Paulo. Faculdade de Odontologia de Bauru2021-10-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/19141810.1590/1678-7757-2021-0089Journal of Applied Oral Science; Vol. 29 (2021); e20210089Journal of Applied Oral Science; Vol. 29 (2021); e20210089Journal of Applied Oral Science; v. 29 (2021); e202100891678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/191418/176439Copyright (c) 2021 Journal of Applied Oral Sciencehttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAlhaija, Elham S. AbuShahin, Ahmad Y. Badran, Serene A. Daher, Saba O. Daher, Hasan O. 2021-10-14T17:12:28Zoai:revistas.usp.br:article/191418Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2021-10-14T17:12:28Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
title Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
spellingShingle Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
Alhaija, Elham S. Abu
Fixed appliance
Laser Doppler Flowmeter
Pain
Archwire
Alignment
title_short Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
title_full Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
title_fullStr Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
title_full_unstemmed Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
title_sort Pulpal blood flow changes and pain scores related to using Superelastic 0.018-inch Nickel Titanium as the first orthodontic alignment archwire: a prospective clinical trial
author Alhaija, Elham S. Abu
author_facet Alhaija, Elham S. Abu
Shahin, Ahmad Y.
Badran, Serene A.
Daher, Saba O.
Daher, Hasan O.
author_role author
author2 Shahin, Ahmad Y.
Badran, Serene A.
Daher, Saba O.
Daher, Hasan O.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Alhaija, Elham S. Abu
Shahin, Ahmad Y.
Badran, Serene A.
Daher, Saba O.
Daher, Hasan O.
dc.subject.por.fl_str_mv Fixed appliance
Laser Doppler Flowmeter
Pain
Archwire
Alignment
topic Fixed appliance
Laser Doppler Flowmeter
Pain
Archwire
Alignment
description Optimal orthodontic force results in maximum rate of tooth movement without tissue damage. Even though starting orthodontic treatment with a thicker archwire may shorten treatment duration, the evidence on the effect of using 0.018-inch NiTi as the first alignment archwire on pulpal blood flow (PBF) status is still scarce. Objectives: to record PBF changes and pain scores associated with using 0.018-inch NiTi as the first alignment archwire during fixed orthodontic treatment. Methodology: Patients were selected from subjects attending postgraduate orthodontic teaching clinics at Jordan University of Science and Technology. In total, forty healthy patients who exhibited mild lower arch crowding were included. A split-mouth trial design was used. Each patient received two archwire sizes at one time joined in the midline by crimpable hook and applied in the lower arch. Patients were assigned into one of two groups based on archwire sizes used. Group 1: 0.014-inch and 0.018-inch NiTi (Six males, 14 females aged 19.4±1.33 years) and Group 2: 0.016-inch and 0.018-inch NiTi (Seven males, 13 females aged 19.6±1.45 years). The archwire size group was randomly allocated with a 1:1 allocation ratio. A Laser Doppler Flowmeter was used to measure PBF at different time intervals (T0-T5). Pain scores were recorded using a visual analogue scale (VAS). A repeated measures ANOVA and a post-hoc Bonferroni comparison tests were conducted to examine differences at the different time points before and during orthodontic alignment. Results: For all studied archwire sizes, PBF decreased 20 minutes after their placement. Most PBF changes occurred within 24hours and continued to decrease until 72 hours after archwire placement where the maximum reduction was reached. Eventually, normal values were reverted within 1 month. PBF changes were similar between all alignment – groups. Conclusions: Initial orthodontic alignment with 0.018-inch NiTi does not cause irreversible changes to pulpal vasculature or produces higher pain scores.
publishDate 2021
dc.date.none.fl_str_mv 2021-10-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/191418
10.1590/1678-7757-2021-0089
url https://www.revistas.usp.br/jaos/article/view/191418
identifier_str_mv 10.1590/1678-7757-2021-0089
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/191418/176439
dc.rights.driver.fl_str_mv Copyright (c) 2021 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 29 (2021); e20210089
Journal of Applied Oral Science; Vol. 29 (2021); e20210089
Journal of Applied Oral Science; v. 29 (2021); e20210089
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221682513739776