The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400018 |
Resumo: | The alternative for the reposition of a missing tooth is the osteointegrated implant being the passive adaptation between the prosthodontic structure and the implant a significant factor for the success of this experiment, a comparative study was done between the two methods for confectioning a single prosthodontic supported by an implant. To do so a screwed implant with a diameter of 3.75mm and a length of 10.0mm (3i Implant innovations, Brasil) was positioned in the middle of a resin block and over it we screwed 15 UCLA abutments shaped and anti-rotationable (137CNB, Conexão Sistemas de Próteses, Brasil) with a torque of 20N.cm without any laboratorial procedure (control group - CTRLG). From a silicon model 15 UCLA-type calcinatable compounds (56CNB, Conexão Sistemas de Próteses, Brasil) were screwed (20 N.cm), received a standard waxing (plain buccal surface) and were cast in titanium (casting group - CG) and other 15 compounds, UCLA - type shaped in titanium (137 CNB, Conexão Sistemas de Próteses, Brasil) received the same standard waxing. These last copings were cast in titanium separated from each other and were laser-welded to the respective abutments on their border (Laser-welding group - LWG). The border adaptation was observed in the implant/compound interface, under measurement microscope, on the y axis, in 4 vestibular, lingual, mesial and distal referential points previously marked on the block. The arithmetical means were obtained and an exploratory data analysis was performed to determine the most appropriate statistical test. Descriptive statistics data (µm) for Control (mean±standard deviation: 13.50 ± 21.80; median 0.00), for Casting (36.20±12.60; 37.00), for Laser (10.50 ±12.90; 3.00) were submitted to Kruskal-Wallis ANOVA, alpha = 5%. Results test showed that distorsion median values differ statistically (kw = 17.40; df =2; p = 0.001<0.05). Dunn's (5%) test show difference between Casting and the two others. Conclusion: on the y axis, the smallest distortion values were obtained by the laser welding group. |
id |
USP-17_6ded6b7885cb797fd0fdb08a9f0210c5 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572004000400018 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser weldingTitaniumDental implantLaser weldingThe alternative for the reposition of a missing tooth is the osteointegrated implant being the passive adaptation between the prosthodontic structure and the implant a significant factor for the success of this experiment, a comparative study was done between the two methods for confectioning a single prosthodontic supported by an implant. To do so a screwed implant with a diameter of 3.75mm and a length of 10.0mm (3i Implant innovations, Brasil) was positioned in the middle of a resin block and over it we screwed 15 UCLA abutments shaped and anti-rotationable (137CNB, Conexão Sistemas de Próteses, Brasil) with a torque of 20N.cm without any laboratorial procedure (control group - CTRLG). From a silicon model 15 UCLA-type calcinatable compounds (56CNB, Conexão Sistemas de Próteses, Brasil) were screwed (20 N.cm), received a standard waxing (plain buccal surface) and were cast in titanium (casting group - CG) and other 15 compounds, UCLA - type shaped in titanium (137 CNB, Conexão Sistemas de Próteses, Brasil) received the same standard waxing. These last copings were cast in titanium separated from each other and were laser-welded to the respective abutments on their border (Laser-welding group - LWG). The border adaptation was observed in the implant/compound interface, under measurement microscope, on the y axis, in 4 vestibular, lingual, mesial and distal referential points previously marked on the block. The arithmetical means were obtained and an exploratory data analysis was performed to determine the most appropriate statistical test. Descriptive statistics data (µm) for Control (mean±standard deviation: 13.50 ± 21.80; median 0.00), for Casting (36.20±12.60; 37.00), for Laser (10.50 ±12.90; 3.00) were submitted to Kruskal-Wallis ANOVA, alpha = 5%. Results test showed that distorsion median values differ statistically (kw = 17.40; df =2; p = 0.001<0.05). Dunn's (5%) test show difference between Casting and the two others. Conclusion: on the y axis, the smallest distortion values were obtained by the laser welding group.Faculdade De Odontologia De Bauru - USP2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400018Journal of Applied Oral Science v.12 n.4 2004reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572004000400018info:eu-repo/semantics/openAccessCosta,Elza Maria Valadares daHoçoya,Luciana SatieBottino,Marco Antônioeng2005-01-10T00:00:00Zoai:scielo:S1678-77572004000400018Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2005-01-10T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
title |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
spellingShingle |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding Costa,Elza Maria Valadares da Titanium Dental implant Laser welding |
title_short |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
title_full |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
title_fullStr |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
title_full_unstemmed |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
title_sort |
The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding |
author |
Costa,Elza Maria Valadares da |
author_facet |
Costa,Elza Maria Valadares da Hoçoya,Luciana Satie Bottino,Marco Antônio |
author_role |
author |
author2 |
Hoçoya,Luciana Satie Bottino,Marco Antônio |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Costa,Elza Maria Valadares da Hoçoya,Luciana Satie Bottino,Marco Antônio |
dc.subject.por.fl_str_mv |
Titanium Dental implant Laser welding |
topic |
Titanium Dental implant Laser welding |
description |
The alternative for the reposition of a missing tooth is the osteointegrated implant being the passive adaptation between the prosthodontic structure and the implant a significant factor for the success of this experiment, a comparative study was done between the two methods for confectioning a single prosthodontic supported by an implant. To do so a screwed implant with a diameter of 3.75mm and a length of 10.0mm (3i Implant innovations, Brasil) was positioned in the middle of a resin block and over it we screwed 15 UCLA abutments shaped and anti-rotationable (137CNB, Conexão Sistemas de Próteses, Brasil) with a torque of 20N.cm without any laboratorial procedure (control group - CTRLG). From a silicon model 15 UCLA-type calcinatable compounds (56CNB, Conexão Sistemas de Próteses, Brasil) were screwed (20 N.cm), received a standard waxing (plain buccal surface) and were cast in titanium (casting group - CG) and other 15 compounds, UCLA - type shaped in titanium (137 CNB, Conexão Sistemas de Próteses, Brasil) received the same standard waxing. These last copings were cast in titanium separated from each other and were laser-welded to the respective abutments on their border (Laser-welding group - LWG). The border adaptation was observed in the implant/compound interface, under measurement microscope, on the y axis, in 4 vestibular, lingual, mesial and distal referential points previously marked on the block. The arithmetical means were obtained and an exploratory data analysis was performed to determine the most appropriate statistical test. Descriptive statistics data (µm) for Control (mean±standard deviation: 13.50 ± 21.80; median 0.00), for Casting (36.20±12.60; 37.00), for Laser (10.50 ±12.90; 3.00) were submitted to Kruskal-Wallis ANOVA, alpha = 5%. Results test showed that distorsion median values differ statistically (kw = 17.40; df =2; p = 0.001<0.05). Dunn's (5%) test show difference between Casting and the two others. Conclusion: on the y axis, the smallest distortion values were obtained by the laser welding group. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400018 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400018 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1678-77572004000400018 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.12 n.4 2004 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936433827053568 |