Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement

Detalhes bibliográficos
Autor(a) principal: Andreatta Filho, Osvaldo Daniel
Data de Publicação: 2005
Outros Autores: Araújo, Maria Auxiliadora Junho de, Bottino, Marco Antonio, Nishioka, Renato Sussumu, Menezes, Marcia Maciel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3248
Resumo: This study evaluated the effect of thermocycling on the bond strength between Procera AllCeram (Nobel-Biocare) and a resin cement (Panavia F, Kuraray CO). Nine ceramic blocks with dimensions of 5x6x6mm were conditioned at one face with Rocatec System (Espe). After, they were luted with Panavia F to composite resin blocks (Clearfil AP-X, Kuraray CO). The nine groups formed by ceramic, cement and composite resin were split up obtaining 75 samples with dimensions of 12x1x1mm and adhesive surface presenting 1mm²±0.1mm² of area. The samples were divided into 3 groups (n=25): G1 - 14 days in distilled water at 37ºC; G2 - 6,000 cycles in water (5ºC - 55ºC - 30s); G3 - 12,000 cycles in water (5ºC - 55ºC - 30s). The samples were tested in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. Data were analyzed by ANOVA and Tukey tests. The results indicated that mean values of rupture tension (MPa) of G1 (10.71 ± 3.54) did not differ statistically (p
id USP-17_701328193280ff5c39b5a9d81f8f2694
oai_identifier_str oai:revistas.usp.br:article/3248
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement Estudo do efeito da ciclagem térmica na resistência da união adesiva entre uma cerâmica aluminizada e um cimento resinoso CerâmicaCimentos de resinaResistência à traçãoCeramicsResin cementsTensile strength This study evaluated the effect of thermocycling on the bond strength between Procera AllCeram (Nobel-Biocare) and a resin cement (Panavia F, Kuraray CO). Nine ceramic blocks with dimensions of 5x6x6mm were conditioned at one face with Rocatec System (Espe). After, they were luted with Panavia F to composite resin blocks (Clearfil AP-X, Kuraray CO). The nine groups formed by ceramic, cement and composite resin were split up obtaining 75 samples with dimensions of 12x1x1mm and adhesive surface presenting 1mm²&plusmn;0.1mm² of area. The samples were divided into 3 groups (n=25): G1 - 14 days in distilled water at 37ºC; G2 - 6,000 cycles in water (5ºC - 55ºC - 30s); G3 - 12,000 cycles in water (5ºC - 55ºC - 30s). The samples were tested in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. Data were analyzed by ANOVA and Tukey tests. The results indicated that mean values of rupture tension (MPa) of G1 (10.71 &plusmn; 3.54) did not differ statistically (p Este trabalho avaliou o efeito da ciclagem térmica sobre a resistência adesiva entre a cerâmica aluminizada (Procera AllCeram, Nobel-Biocare) e um cimento resinoso (Panavia F, Kuraray CO). Nove blocos de cerâmica, com dimensões de 5x6x6mm, foram condicionados em uma de suas faces com o Sistema Rocatec (ESPE). A seguir foram cimentados a blocos de resina composta (Clearfil AP-X, Kuraray CO). Os conjuntos cerâmica-cimento-resina foram cortados em 75 corpos-de-prova com formato retangular com dimensões de 12x1x1mm e superfície adesiva apresentando 1mm² &plusmn; 0,1mm². Os corpos-de-prova foram divididos em três grupos (n=25): G1 - 14 dias em água destilada a 37ºC, G2 - 6000 ciclos em água (5ºC e 55ºC) e G3 - 12000 ciclos em água (5ºC e 55ºC). Os corpos-de-prova foram ensaiados sob velocidade de 1mm/min em máquina de ensaio universal (EMIC). Os dados foram tratados estatisticamente com os testes de Anova e Tukey e indicaram que os valores médios de tensão de rupturas (MPa) de G1 (10,71 &plusmn; 3,54) não diferiram estatisticamente (p < 5%) de G2 (9,01 &plusmn; 3,90), porém houve diferença significativa entre G1 e G3 (7,28 &plusmn; 3,00). Concluiu-se que a ciclagem térmica diminuiu a resistência adesiva significativamente quando os corpos-de-prova foram submetidos a 12000 ciclos. Universidade de São Paulo. Faculdade de Odontologia de Bauru2005-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/324810.1590/S1678-77572005000100011Journal of Applied Oral Science; Vol. 13 No. 1 (2005); 53-57 Journal of Applied Oral Science; Vol. 13 Núm. 1 (2005); 53-57 Journal of Applied Oral Science; v. 13 n. 1 (2005); 53-57 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3248/3938Copyright (c) 2005 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessAndreatta Filho, Osvaldo DanielAraújo, Maria Auxiliadora Junho deBottino, Marco AntonioNishioka, Renato SussumuMenezes, Marcia Maciel2012-04-27T11:49:35Zoai:revistas.usp.br:article/3248Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:49:35Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
Estudo do efeito da ciclagem térmica na resistência da união adesiva entre uma cerâmica aluminizada e um cimento resinoso
title Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
spellingShingle Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
Andreatta Filho, Osvaldo Daniel
Cerâmica
Cimentos de resina
Resistência à tração
Ceramics
Resin cements
Tensile strength
title_short Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
title_full Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
title_fullStr Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
title_full_unstemmed Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
title_sort Study of thermocycling effect on the bond strength between an aluminous ceramic and a resin cement
author Andreatta Filho, Osvaldo Daniel
author_facet Andreatta Filho, Osvaldo Daniel
Araújo, Maria Auxiliadora Junho de
Bottino, Marco Antonio
Nishioka, Renato Sussumu
Menezes, Marcia Maciel
author_role author
author2 Araújo, Maria Auxiliadora Junho de
Bottino, Marco Antonio
Nishioka, Renato Sussumu
Menezes, Marcia Maciel
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Andreatta Filho, Osvaldo Daniel
Araújo, Maria Auxiliadora Junho de
Bottino, Marco Antonio
Nishioka, Renato Sussumu
Menezes, Marcia Maciel
dc.subject.por.fl_str_mv Cerâmica
Cimentos de resina
Resistência à tração
Ceramics
Resin cements
Tensile strength
topic Cerâmica
Cimentos de resina
Resistência à tração
Ceramics
Resin cements
Tensile strength
description This study evaluated the effect of thermocycling on the bond strength between Procera AllCeram (Nobel-Biocare) and a resin cement (Panavia F, Kuraray CO). Nine ceramic blocks with dimensions of 5x6x6mm were conditioned at one face with Rocatec System (Espe). After, they were luted with Panavia F to composite resin blocks (Clearfil AP-X, Kuraray CO). The nine groups formed by ceramic, cement and composite resin were split up obtaining 75 samples with dimensions of 12x1x1mm and adhesive surface presenting 1mm²&plusmn;0.1mm² of area. The samples were divided into 3 groups (n=25): G1 - 14 days in distilled water at 37ºC; G2 - 6,000 cycles in water (5ºC - 55ºC - 30s); G3 - 12,000 cycles in water (5ºC - 55ºC - 30s). The samples were tested in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. Data were analyzed by ANOVA and Tukey tests. The results indicated that mean values of rupture tension (MPa) of G1 (10.71 &plusmn; 3.54) did not differ statistically (p
publishDate 2005
dc.date.none.fl_str_mv 2005-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3248
10.1590/S1678-77572005000100011
url https://www.revistas.usp.br/jaos/article/view/3248
identifier_str_mv 10.1590/S1678-77572005000100011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3248/3938
dc.rights.driver.fl_str_mv Copyright (c) 2005 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2005 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 13 No. 1 (2005); 53-57
Journal of Applied Oral Science; Vol. 13 Núm. 1 (2005); 53-57
Journal of Applied Oral Science; v. 13 n. 1 (2005); 53-57
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221671998619648