Histomorphometric analysis of pure titanium implants with porous surface versus rough surface
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300013 |
Resumo: | The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface. |
id |
USP-17_746a470e2af92e3e423ddc8218bb4932 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572006000300013 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surfaceOsseointegrationImplantsPorousRoughSurfaceBoneThe purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.Faculdade De Odontologia De Bauru - USP2006-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300013Journal of Applied Oral Science v.14 n.3 2006reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572006000300013info:eu-repo/semantics/openAccessBrentel,Aline ScaloneVasconcellos,Luana Marotta Reis deOliveira,Marize VarellaGraça,Mário Lima de AlencastroVasconcellos,Luis Gustavo Oliveira deCairo,Carlos Alberto AlvesCarvalho,Yasmin Rodarteeng2006-08-14T00:00:00Zoai:scielo:S1678-77572006000300013Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2006-08-14T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
title |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
spellingShingle |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface Brentel,Aline Scalone Osseointegration Implants Porous Rough Surface Bone |
title_short |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
title_full |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
title_fullStr |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
title_full_unstemmed |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
title_sort |
Histomorphometric analysis of pure titanium implants with porous surface versus rough surface |
author |
Brentel,Aline Scalone |
author_facet |
Brentel,Aline Scalone Vasconcellos,Luana Marotta Reis de Oliveira,Marize Varella Graça,Mário Lima de Alencastro Vasconcellos,Luis Gustavo Oliveira de Cairo,Carlos Alberto Alves Carvalho,Yasmin Rodarte |
author_role |
author |
author2 |
Vasconcellos,Luana Marotta Reis de Oliveira,Marize Varella Graça,Mário Lima de Alencastro Vasconcellos,Luis Gustavo Oliveira de Cairo,Carlos Alberto Alves Carvalho,Yasmin Rodarte |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Brentel,Aline Scalone Vasconcellos,Luana Marotta Reis de Oliveira,Marize Varella Graça,Mário Lima de Alencastro Vasconcellos,Luis Gustavo Oliveira de Cairo,Carlos Alberto Alves Carvalho,Yasmin Rodarte |
dc.subject.por.fl_str_mv |
Osseointegration Implants Porous Rough Surface Bone |
topic |
Osseointegration Implants Porous Rough Surface Bone |
description |
The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000300013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1678-77572006000300013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.14 n.3 2006 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936434292621312 |