The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks

Detalhes bibliográficos
Autor(a) principal: Vasconcellos, Diego Klee de
Data de Publicação: 2005
Outros Autores: Bottino, Marco Antonio, Nishioka, Renato Sussumu, Valandro, Luiz Felipe, Costa, Elza Maria Valadares da
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3261
Resumo: OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p
id USP-17_b4de1f775341f49c5a792f9d26041aa0
oai_identifier_str oai:revistas.usp.br:article/3261
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks Avaliação do efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes Implantes dentáriosOsseointegraçãoPrótese dentária fixada por implanteTorquedesadaptaçãoDental implantsOsseointegrationImplant-supported dental prosthesisTorquemisfit OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p O presente estudo avaliou o efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes. A investigação foi conduzida baseada em resultados fornecidos por nove estruturas metálicas implanto-suportadas de seis elementos (02 retentores e 04 pônticos), retidas por parafusos. A mensuração da desadaptação marginal foi realizada com auxílio de microscópio óptico, nos seguintes momentos: M1: aperto com chave manual até a primeira resistência do parafuso; M2: aperto utilizando torquímetro mecânico com 10Ncm e M3: aperto utilizando torquímetro mecânico com 20Ncm. As médias de desadaptação foram submetidas à análise estatística (ANOVA e Tukey). O emprego de torquímetros mecânicos, independente do valor de torque, determinou redução significativa na abertura marginal (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2005-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/326110.1590/S1678-77572005000200005Journal of Applied Oral Science; Vol. 13 No. 2 (2005); 120-125 Journal of Applied Oral Science; Vol. 13 Núm. 2 (2005); 120-125 Journal of Applied Oral Science; v. 13 n. 2 (2005); 120-125 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3261/3951Copyright (c) 2005 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessVasconcellos, Diego Klee deBottino, Marco AntonioNishioka, Renato SussumuValandro, Luiz FelipeCosta, Elza Maria Valadares da2012-04-27T11:50:04Zoai:revistas.usp.br:article/3261Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:50:04Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
Avaliação do efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes
title The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
spellingShingle The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
Vasconcellos, Diego Klee de
Implantes dentários
Osseointegração
Prótese dentária fixada por implante
Torque
desadaptação
Dental implants
Osseointegration
Implant-supported dental prosthesis
Torque
misfit
title_short The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
title_full The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
title_fullStr The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
title_full_unstemmed The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
title_sort The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks
author Vasconcellos, Diego Klee de
author_facet Vasconcellos, Diego Klee de
Bottino, Marco Antonio
Nishioka, Renato Sussumu
Valandro, Luiz Felipe
Costa, Elza Maria Valadares da
author_role author
author2 Bottino, Marco Antonio
Nishioka, Renato Sussumu
Valandro, Luiz Felipe
Costa, Elza Maria Valadares da
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Vasconcellos, Diego Klee de
Bottino, Marco Antonio
Nishioka, Renato Sussumu
Valandro, Luiz Felipe
Costa, Elza Maria Valadares da
dc.subject.por.fl_str_mv Implantes dentários
Osseointegração
Prótese dentária fixada por implante
Torque
desadaptação
Dental implants
Osseointegration
Implant-supported dental prosthesis
Torque
misfit
topic Implantes dentários
Osseointegração
Prótese dentária fixada por implante
Torque
desadaptação
Dental implants
Osseointegration
Implant-supported dental prosthesis
Torque
misfit
description OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p
publishDate 2005
dc.date.none.fl_str_mv 2005-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3261
10.1590/S1678-77572005000200005
url https://www.revistas.usp.br/jaos/article/view/3261
identifier_str_mv 10.1590/S1678-77572005000200005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3261/3951
dc.rights.driver.fl_str_mv Copyright (c) 2005 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2005 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 13 No. 2 (2005); 120-125
Journal of Applied Oral Science; Vol. 13 Núm. 2 (2005); 120-125
Journal of Applied Oral Science; v. 13 n. 2 (2005); 120-125
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221672025882624