Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave

Detalhes bibliográficos
Autor(a) principal: Figuerôa, Rosana Marques Silva
Data de Publicação: 2022
Outros Autores: Conterno, Bruna, Arrais, César Augusto Galvão, Sugio, Carolina Yoshi Campos, Urban, Vanessa Migliorini, Neppelenbroek, Karin Hermana
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/201387
Resumo: The proper selection of polymerization cycle is important to prevent overheating of the monomer that could cause degradation, porosity and, consequently, deleterious effects on the denture base properties. Objective: This study evaluated the porosity, water sorption and solubility of acrylic resins (Vipi Cril-VC and Vipi Wave-VW) after conventional or microwave polymerization cycles. Material and Methods: Specimens (n = 10) were made and cured: 1-WB = 65°C during 90 min + boiling during 90 min (VC cycle - control group); 2-M25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W (VW cycle); 3-M3 = 3 min at 550 W; and 4-M5 = 5 min at 650 W. Afterward, they were polished and dried in a dessicator until a constant mass was reached. Specimens were then immersed in distilled water at 37°C and weighed regularly until a constant mass was achieved. For porosity, an additional weight was made with the specimen immediately immersed in distilled water. For water sorption and solubility, the specimens were dried again until equilibrium was reached. Data were submitted to 2 way-ANOVA and Tukey HSD (α=0.05). Results: Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. However, there was a significant difference among groups for these both properties (P<0.013). The highest sorption (2.43%) and solubility (0.13%) values were obtained for WB and M3, respectively. Conclusions: The conventional acrylic resin could be polymerized in a microwave since both the materials showed similar performance in the evaluated properties. Shor
id USP-17_fd6e8d6346a28982376a6599ffe901bd
oai_identifier_str oai:revistas.usp.br:article/201387
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwavePolymethyl methacrylatePolymerizationPorositySolubilitySorptionThe proper selection of polymerization cycle is important to prevent overheating of the monomer that could cause degradation, porosity and, consequently, deleterious effects on the denture base properties. Objective: This study evaluated the porosity, water sorption and solubility of acrylic resins (Vipi Cril-VC and Vipi Wave-VW) after conventional or microwave polymerization cycles. Material and Methods: Specimens (n = 10) were made and cured: 1-WB = 65°C during 90 min + boiling during 90 min (VC cycle - control group); 2-M25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W (VW cycle); 3-M3 = 3 min at 550 W; and 4-M5 = 5 min at 650 W. Afterward, they were polished and dried in a dessicator until a constant mass was reached. Specimens were then immersed in distilled water at 37°C and weighed regularly until a constant mass was achieved. For porosity, an additional weight was made with the specimen immediately immersed in distilled water. For water sorption and solubility, the specimens were dried again until equilibrium was reached. Data were submitted to 2 way-ANOVA and Tukey HSD (α=0.05). Results: Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. However, there was a significant difference among groups for these both properties (P<0.013). The highest sorption (2.43%) and solubility (0.13%) values were obtained for WB and M3, respectively. Conclusions: The conventional acrylic resin could be polymerized in a microwave since both the materials showed similar performance in the evaluated properties. ShorUniversidade de São Paulo. Faculdade de Odontologia de Bauru2022-08-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/20138710.1590/1678-7757-2017-0383 Journal of Applied Oral Science; Vol. 26 (2018); e20170383Journal of Applied Oral Science; Vol. 26 (2018); e20170383Journal of Applied Oral Science; v. 26 (2018); e201703831678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/201387/185484Copyright (c) 2022 Journal of Applied Oral Sciencehttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessFiguerôa, Rosana Marques SilvaConterno, BrunaArrais, César Augusto GalvãoSugio, Carolina Yoshi CamposUrban, Vanessa MiglioriniNeppelenbroek, Karin Hermana2022-08-23T19:35:05Zoai:revistas.usp.br:article/201387Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2022-08-23T19:35:05Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
title Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
spellingShingle Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
Figuerôa, Rosana Marques Silva
Polymethyl methacrylate
Polymerization
Porosity
Solubility
Sorption
title_short Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
title_full Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
title_fullStr Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
title_full_unstemmed Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
title_sort Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave
author Figuerôa, Rosana Marques Silva
author_facet Figuerôa, Rosana Marques Silva
Conterno, Bruna
Arrais, César Augusto Galvão
Sugio, Carolina Yoshi Campos
Urban, Vanessa Migliorini
Neppelenbroek, Karin Hermana
author_role author
author2 Conterno, Bruna
Arrais, César Augusto Galvão
Sugio, Carolina Yoshi Campos
Urban, Vanessa Migliorini
Neppelenbroek, Karin Hermana
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Figuerôa, Rosana Marques Silva
Conterno, Bruna
Arrais, César Augusto Galvão
Sugio, Carolina Yoshi Campos
Urban, Vanessa Migliorini
Neppelenbroek, Karin Hermana
dc.subject.por.fl_str_mv Polymethyl methacrylate
Polymerization
Porosity
Solubility
Sorption
topic Polymethyl methacrylate
Polymerization
Porosity
Solubility
Sorption
description The proper selection of polymerization cycle is important to prevent overheating of the monomer that could cause degradation, porosity and, consequently, deleterious effects on the denture base properties. Objective: This study evaluated the porosity, water sorption and solubility of acrylic resins (Vipi Cril-VC and Vipi Wave-VW) after conventional or microwave polymerization cycles. Material and Methods: Specimens (n = 10) were made and cured: 1-WB = 65°C during 90 min + boiling during 90 min (VC cycle - control group); 2-M25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W (VW cycle); 3-M3 = 3 min at 550 W; and 4-M5 = 5 min at 650 W. Afterward, they were polished and dried in a dessicator until a constant mass was reached. Specimens were then immersed in distilled water at 37°C and weighed regularly until a constant mass was achieved. For porosity, an additional weight was made with the specimen immediately immersed in distilled water. For water sorption and solubility, the specimens were dried again until equilibrium was reached. Data were submitted to 2 way-ANOVA and Tukey HSD (α=0.05). Results: Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. However, there was a significant difference among groups for these both properties (P<0.013). The highest sorption (2.43%) and solubility (0.13%) values were obtained for WB and M3, respectively. Conclusions: The conventional acrylic resin could be polymerized in a microwave since both the materials showed similar performance in the evaluated properties. Shor
publishDate 2022
dc.date.none.fl_str_mv 2022-08-23
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/201387
10.1590/1678-7757-2017-0383
url https://www.revistas.usp.br/jaos/article/view/201387
identifier_str_mv 10.1590/1678-7757-2017-0383
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/201387/185484
dc.rights.driver.fl_str_mv Copyright (c) 2022 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2022 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 26 (2018); e20170383
Journal of Applied Oral Science; Vol. 26 (2018); e20170383
Journal of Applied Oral Science; v. 26 (2018); e20170383
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221683176439808