Are torque values of preadjusted brackets precise?

Detalhes bibliográficos
Autor(a) principal: Streva,Alessandra Motta
Data de Publicação: 2011
Outros Autores: Cotrim-Ferreira,Flávio Augusto, Garib,Daniela Gamba, Carvalho,Paulo Eduardo Guedes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000400004
Resumo: OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.
id USP-17_fe6756b1699fea7789b62e7f1b76edae
oai_identifier_str oai:scielo:S1678-77572011000400004
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Are torque values of preadjusted brackets precise?TorqueOrthodontic bracketsCuspidOBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.Faculdade De Odontologia De Bauru - USP2011-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000400004Journal of Applied Oral Science v.19 n.4 2011reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572011005000003info:eu-repo/semantics/openAccessStreva,Alessandra MottaCotrim-Ferreira,Flávio AugustoGarib,Daniela GambaCarvalho,Paulo Eduardo Guedeseng2014-06-11T00:00:00Zoai:scielo:S1678-77572011000400004Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2014-06-11T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Are torque values of preadjusted brackets precise?
title Are torque values of preadjusted brackets precise?
spellingShingle Are torque values of preadjusted brackets precise?
Streva,Alessandra Motta
Torque
Orthodontic brackets
Cuspid
title_short Are torque values of preadjusted brackets precise?
title_full Are torque values of preadjusted brackets precise?
title_fullStr Are torque values of preadjusted brackets precise?
title_full_unstemmed Are torque values of preadjusted brackets precise?
title_sort Are torque values of preadjusted brackets precise?
author Streva,Alessandra Motta
author_facet Streva,Alessandra Motta
Cotrim-Ferreira,Flávio Augusto
Garib,Daniela Gamba
Carvalho,Paulo Eduardo Guedes
author_role author
author2 Cotrim-Ferreira,Flávio Augusto
Garib,Daniela Gamba
Carvalho,Paulo Eduardo Guedes
author2_role author
author
author
dc.contributor.author.fl_str_mv Streva,Alessandra Motta
Cotrim-Ferreira,Flávio Augusto
Garib,Daniela Gamba
Carvalho,Paulo Eduardo Guedes
dc.subject.por.fl_str_mv Torque
Orthodontic brackets
Cuspid
topic Torque
Orthodontic brackets
Cuspid
description OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.
publishDate 2011
dc.date.none.fl_str_mv 2011-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000400004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572011000400004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-77572011005000003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.19 n.4 2011
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936437040939008