Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study

Detalhes bibliográficos
Autor(a) principal: Morales, Marcia Maria
Data de Publicação: 2010
Outros Autores: Anacleto, Alexandre, Buchdid, Marcello Azem, Simeoni, Paulo Ricardo Baggio, Ledesma, Sergio, Cêntola, Crescêncio, Anacleto, João Carlos, Aldrovani, Marcela, Piccinato, Carlos Eli
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Clinics
Texto Completo: https://www.revistas.usp.br/clinics/article/view/18465
Resumo: OBJECTIVES: A duplex ultrasound study was performed to investigate morphological and hemodynamic patterns of carotid stenoses treated by endarterectomy with patch closure versus stenting. MATERIALS AND METHOD: Twenty-nine carotid stenoses were treated with stenting and 65 with patch closure. Duplex ultrasound parameters (luminal diameter, mm; peak systolic velocity and end-diastolic velocity, cm/s) were measured 24 hours after the procedures and also at 12 months post-procedure. Residual stenoses (immediately postprocedure) and restenoses (within 12 months of procedure) were defined as narrowings of >;50% on duplex ultrasound examination. RESULTS: In stented patients, the luminal diameter of the proximal internal carotid artery increased in the interval between the 24-hour and 12-month post-procedure studies, while in the patch closure patients, the diameter decreased. Carotid hemodynamics normalized immediately after both patching and stenting and remained relatively stable thereafter up to 12 months. No statistically elevated flow velocities (in the absence of residual stenosis or restenosis) were observed in the patched or stented carotid arteries. No significant differences in residual stenosis rates were observed between the stenting group (3 cases, 10.34%) and the patch closure group (1 case, 1.53%, P = 0.08). At 12 months, 2 stenting patients (6.88%) and 2 patch closure patients (3.07%) had $50% restenosis (P = 0.58). One case of late stroke due to restenosis was observed in the stenting group; the patient died 12 months postoperatively, before receiving new intervention. CONCLUSION: Measurements over time in luminal diameter signalized differences in arterial remodeling mechanisms between patched and stented carotids. Both stenting and patch closure were associated with carotid patency and flow restoration. This study does not support a general approach to new velocity criteria indiscriminately applied to stented or patched carotids.
id USP-19_481b3c73a20907af843f55cab2955750
oai_identifier_str oai:revistas.usp.br:article/18465
network_acronym_str USP-19
network_name_str Clinics
repository_id_str
spelling Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study Bovine pericardial patch angioplastyCarotid artery stenosisCarotid endarterectomyCarotid stentingDuplex ultrasound OBJECTIVES: A duplex ultrasound study was performed to investigate morphological and hemodynamic patterns of carotid stenoses treated by endarterectomy with patch closure versus stenting. MATERIALS AND METHOD: Twenty-nine carotid stenoses were treated with stenting and 65 with patch closure. Duplex ultrasound parameters (luminal diameter, mm; peak systolic velocity and end-diastolic velocity, cm/s) were measured 24 hours after the procedures and also at 12 months post-procedure. Residual stenoses (immediately postprocedure) and restenoses (within 12 months of procedure) were defined as narrowings of >;50% on duplex ultrasound examination. RESULTS: In stented patients, the luminal diameter of the proximal internal carotid artery increased in the interval between the 24-hour and 12-month post-procedure studies, while in the patch closure patients, the diameter decreased. Carotid hemodynamics normalized immediately after both patching and stenting and remained relatively stable thereafter up to 12 months. No statistically elevated flow velocities (in the absence of residual stenosis or restenosis) were observed in the patched or stented carotid arteries. No significant differences in residual stenosis rates were observed between the stenting group (3 cases, 10.34%) and the patch closure group (1 case, 1.53%, P = 0.08). At 12 months, 2 stenting patients (6.88%) and 2 patch closure patients (3.07%) had $50% restenosis (P = 0.58). One case of late stroke due to restenosis was observed in the stenting group; the patient died 12 months postoperatively, before receiving new intervention. CONCLUSION: Measurements over time in luminal diameter signalized differences in arterial remodeling mechanisms between patched and stented carotids. Both stenting and patch closure were associated with carotid patency and flow restoration. This study does not support a general approach to new velocity criteria indiscriminately applied to stented or patched carotids. Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/clinics/article/view/1846510.1590/S1807-59322010001200015Clinics; v. 65 n. 12 (2010); 1315-1323 Clinics; Vol. 65 Núm. 12 (2010); 1315-1323 Clinics; Vol. 65 No. 12 (2010); 1315-1323 1980-53221807-5932reponame:Clinicsinstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/clinics/article/view/18465/20528Morales, Marcia MariaAnacleto, AlexandreBuchdid, Marcello AzemSimeoni, Paulo Ricardo BaggioLedesma, SergioCêntola, CrescêncioAnacleto, João CarlosAldrovani, MarcelaPiccinato, Carlos Eliinfo:eu-repo/semantics/openAccess2012-05-23T11:25:45Zoai:revistas.usp.br:article/18465Revistahttps://www.revistas.usp.br/clinicsPUBhttps://www.revistas.usp.br/clinics/oai||clinics@hc.fm.usp.br1980-53221807-5932opendoar:2012-05-23T11:25:45Clinics - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
title Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
spellingShingle Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
Morales, Marcia Maria
Bovine pericardial patch angioplasty
Carotid artery stenosis
Carotid endarterectomy
Carotid stenting
Duplex ultrasound
title_short Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
title_full Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
title_fullStr Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
title_full_unstemmed Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
title_sort Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study
author Morales, Marcia Maria
author_facet Morales, Marcia Maria
Anacleto, Alexandre
Buchdid, Marcello Azem
Simeoni, Paulo Ricardo Baggio
Ledesma, Sergio
Cêntola, Crescêncio
Anacleto, João Carlos
Aldrovani, Marcela
Piccinato, Carlos Eli
author_role author
author2 Anacleto, Alexandre
Buchdid, Marcello Azem
Simeoni, Paulo Ricardo Baggio
Ledesma, Sergio
Cêntola, Crescêncio
Anacleto, João Carlos
Aldrovani, Marcela
Piccinato, Carlos Eli
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Morales, Marcia Maria
Anacleto, Alexandre
Buchdid, Marcello Azem
Simeoni, Paulo Ricardo Baggio
Ledesma, Sergio
Cêntola, Crescêncio
Anacleto, João Carlos
Aldrovani, Marcela
Piccinato, Carlos Eli
dc.subject.por.fl_str_mv Bovine pericardial patch angioplasty
Carotid artery stenosis
Carotid endarterectomy
Carotid stenting
Duplex ultrasound
topic Bovine pericardial patch angioplasty
Carotid artery stenosis
Carotid endarterectomy
Carotid stenting
Duplex ultrasound
description OBJECTIVES: A duplex ultrasound study was performed to investigate morphological and hemodynamic patterns of carotid stenoses treated by endarterectomy with patch closure versus stenting. MATERIALS AND METHOD: Twenty-nine carotid stenoses were treated with stenting and 65 with patch closure. Duplex ultrasound parameters (luminal diameter, mm; peak systolic velocity and end-diastolic velocity, cm/s) were measured 24 hours after the procedures and also at 12 months post-procedure. Residual stenoses (immediately postprocedure) and restenoses (within 12 months of procedure) were defined as narrowings of >;50% on duplex ultrasound examination. RESULTS: In stented patients, the luminal diameter of the proximal internal carotid artery increased in the interval between the 24-hour and 12-month post-procedure studies, while in the patch closure patients, the diameter decreased. Carotid hemodynamics normalized immediately after both patching and stenting and remained relatively stable thereafter up to 12 months. No statistically elevated flow velocities (in the absence of residual stenosis or restenosis) were observed in the patched or stented carotid arteries. No significant differences in residual stenosis rates were observed between the stenting group (3 cases, 10.34%) and the patch closure group (1 case, 1.53%, P = 0.08). At 12 months, 2 stenting patients (6.88%) and 2 patch closure patients (3.07%) had $50% restenosis (P = 0.58). One case of late stroke due to restenosis was observed in the stenting group; the patient died 12 months postoperatively, before receiving new intervention. CONCLUSION: Measurements over time in luminal diameter signalized differences in arterial remodeling mechanisms between patched and stented carotids. Both stenting and patch closure were associated with carotid patency and flow restoration. This study does not support a general approach to new velocity criteria indiscriminately applied to stented or patched carotids.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/clinics/article/view/18465
10.1590/S1807-59322010001200015
url https://www.revistas.usp.br/clinics/article/view/18465
identifier_str_mv 10.1590/S1807-59322010001200015
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/clinics/article/view/18465/20528
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
dc.source.none.fl_str_mv Clinics; v. 65 n. 12 (2010); 1315-1323
Clinics; Vol. 65 Núm. 12 (2010); 1315-1323
Clinics; Vol. 65 No. 12 (2010); 1315-1323
1980-5322
1807-5932
reponame:Clinics
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Clinics
collection Clinics
repository.name.fl_str_mv Clinics - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||clinics@hc.fm.usp.br
_version_ 1787713171494010880