Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados

Detalhes bibliográficos
Autor(a) principal: Crozeta, Bruno Monguilhott
Data de Publicação: 2018
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USP
Texto Completo: http://www.teses.usp.br/teses/disponiveis/58/58133/tde-19092018-081259/
Resumo: O objetivo do presente estudo foi avaliar, por meio de microtomografia computadorizada (micro-CT), o volume de remanescente de diferentes materiais obturadores (AH Plus e BC Sealer), após o uso do instrumento R50 e de técnicas complementares (inserto ultrassônico e instrumento XP-endo Finisher R) em canais radiculares ovais. Vinte e oito raízes distais de molares inferiores, com canal único e oval, foram selecionadas por micro-CT, preparados com instrumento R40 (40.06), e obturados com os seguintes cimentos: AH Plus (n = 14) e BC Sealer (n = 14), e submetidos à ciclagem térmica. Em seguida foi realizada a remoção inicial com R50 e os dentes foram escaneados no micro-CT para determinação do volume remanescente inicial de material obturador, e posterior complementação com inserto ultrassônico (n = 7) ou XP-endo Finisher R (n = 7). Os espécimes foram novamente escaneados, e a partir do volume inicial de material obturador (volinicial) e volume de material obturador remanescente (volrem) em mm3, obteve-se a % de volume de material remanescente após as técnicas de complementação (%volrem=volrem×100/volinicial). Para a análise qualitativa, as imagens de MEV e os modelos tridimensionais obtidos por micro-CT, foram avaliados em relação à presença/ausência e localização do remanescente de material obturador nos canais radiculares. Os dados de %volrem e volume remanescente de material obturador após o uso do instrumento R50 (%volR50) foram comparados pelo teste T, e os dados de %volrem foram submetidos ao teste ANOVA, seguido de teste de Tukey (nível de probabilidade de 95%). Considerando o canal como um todo, as técnicas de complementação promoveram redução significativa do volume remanescente de material obturador, sendo que menores valores foram observados quando utilizado o inserto ultrassônico (8,93 ± 6,12) em relação ao XP-endo Finisher R (16,26 ± 14,71) (P = 0,043). Quanto aos cimentos, pode-se observar que o BC Sealer apresentou maiores quantidades de remanescente (18,87 ± 13,42) quando comparado ao cimento AH Plus (6,33 ± 4,25) (P < 0,001). Em relação à avaliação por terços radiculares, observou-se que quando utilizado o instrumento XP-endo Finisher R, não houve diferença do volume de material remanescente entre os terços, independente do cimento obturador utilizado (P > 0,05). Entretanto, ao se utilizar inserto ultrassônico e cimento AH Plus, maiores valores de volume de material remanescente foram observados no terço apical (23,08 ± 18,1) (P < 0,001), e quando utilizado o BC Sealer, no terço médio (15,53 ± 6,0) (P = 0,022). Conclui-se que as técnicas de complementação aumentaram a remoção de material obturador, entretanto, nenhuma das técnicas removeu por completo o material obturador do canal radicular, principalmente quando o dente foi obturado com o cimento BC Sealer
id USP_47840df0605ba85db1ee8e9e964cd8c0
oai_identifier_str oai:teses.usp.br:tde-19092018-081259
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatadosEvaluation of the removal of different filling materials using reciprocating system followed by two supplementary techniques in flattened root canalsAnatomical challengesComputerized microtomographyDesafios anatômicosEndodontic retreatmentMicrotomografia computadorizadaRetratamento endodônticoO objetivo do presente estudo foi avaliar, por meio de microtomografia computadorizada (micro-CT), o volume de remanescente de diferentes materiais obturadores (AH Plus e BC Sealer), após o uso do instrumento R50 e de técnicas complementares (inserto ultrassônico e instrumento XP-endo Finisher R) em canais radiculares ovais. Vinte e oito raízes distais de molares inferiores, com canal único e oval, foram selecionadas por micro-CT, preparados com instrumento R40 (40.06), e obturados com os seguintes cimentos: AH Plus (n = 14) e BC Sealer (n = 14), e submetidos à ciclagem térmica. Em seguida foi realizada a remoção inicial com R50 e os dentes foram escaneados no micro-CT para determinação do volume remanescente inicial de material obturador, e posterior complementação com inserto ultrassônico (n = 7) ou XP-endo Finisher R (n = 7). Os espécimes foram novamente escaneados, e a partir do volume inicial de material obturador (volinicial) e volume de material obturador remanescente (volrem) em mm3, obteve-se a % de volume de material remanescente após as técnicas de complementação (%volrem=volrem×100/volinicial). Para a análise qualitativa, as imagens de MEV e os modelos tridimensionais obtidos por micro-CT, foram avaliados em relação à presença/ausência e localização do remanescente de material obturador nos canais radiculares. Os dados de %volrem e volume remanescente de material obturador após o uso do instrumento R50 (%volR50) foram comparados pelo teste T, e os dados de %volrem foram submetidos ao teste ANOVA, seguido de teste de Tukey (nível de probabilidade de 95%). Considerando o canal como um todo, as técnicas de complementação promoveram redução significativa do volume remanescente de material obturador, sendo que menores valores foram observados quando utilizado o inserto ultrassônico (8,93 ± 6,12) em relação ao XP-endo Finisher R (16,26 ± 14,71) (P = 0,043). Quanto aos cimentos, pode-se observar que o BC Sealer apresentou maiores quantidades de remanescente (18,87 ± 13,42) quando comparado ao cimento AH Plus (6,33 ± 4,25) (P < 0,001). Em relação à avaliação por terços radiculares, observou-se que quando utilizado o instrumento XP-endo Finisher R, não houve diferença do volume de material remanescente entre os terços, independente do cimento obturador utilizado (P > 0,05). Entretanto, ao se utilizar inserto ultrassônico e cimento AH Plus, maiores valores de volume de material remanescente foram observados no terço apical (23,08 ± 18,1) (P < 0,001), e quando utilizado o BC Sealer, no terço médio (15,53 ± 6,0) (P = 0,022). Conclui-se que as técnicas de complementação aumentaram a remoção de material obturador, entretanto, nenhuma das técnicas removeu por completo o material obturador do canal radicular, principalmente quando o dente foi obturado com o cimento BC SealerThe aim of the present study was to evaluate, by micro-computed tomography (micro-CT), the remaining volume of different filling materials (AH Plus and BC Sealer) after using the R50 instrument and supplementary techniques (ultrasonic insert and XP-endo Finisher R instrument) in oval-shaped root canals. Twenty-eight distal roots of mandibular molars with single and oval-shaped canals, verified by micro-CT, were prepared with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC Sealer. with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC SealerBiblioteca Digitais de Teses e Dissertações da USPSousa Neto, Manoel Damião deCrozeta, Bruno Monguilhott2018-04-18info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/58/58133/tde-19092018-081259/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesspor2019-07-25T23:17:23Zoai:teses.usp.br:tde-19092018-081259Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212019-07-25T23:17:23Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
Evaluation of the removal of different filling materials using reciprocating system followed by two supplementary techniques in flattened root canals
title Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
spellingShingle Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
Crozeta, Bruno Monguilhott
Anatomical challenges
Computerized microtomography
Desafios anatômicos
Endodontic retreatment
Microtomografia computadorizada
Retratamento endodôntico
title_short Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
title_full Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
title_fullStr Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
title_full_unstemmed Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
title_sort Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados
author Crozeta, Bruno Monguilhott
author_facet Crozeta, Bruno Monguilhott
author_role author
dc.contributor.none.fl_str_mv Sousa Neto, Manoel Damião de
dc.contributor.author.fl_str_mv Crozeta, Bruno Monguilhott
dc.subject.por.fl_str_mv Anatomical challenges
Computerized microtomography
Desafios anatômicos
Endodontic retreatment
Microtomografia computadorizada
Retratamento endodôntico
topic Anatomical challenges
Computerized microtomography
Desafios anatômicos
Endodontic retreatment
Microtomografia computadorizada
Retratamento endodôntico
description O objetivo do presente estudo foi avaliar, por meio de microtomografia computadorizada (micro-CT), o volume de remanescente de diferentes materiais obturadores (AH Plus e BC Sealer), após o uso do instrumento R50 e de técnicas complementares (inserto ultrassônico e instrumento XP-endo Finisher R) em canais radiculares ovais. Vinte e oito raízes distais de molares inferiores, com canal único e oval, foram selecionadas por micro-CT, preparados com instrumento R40 (40.06), e obturados com os seguintes cimentos: AH Plus (n = 14) e BC Sealer (n = 14), e submetidos à ciclagem térmica. Em seguida foi realizada a remoção inicial com R50 e os dentes foram escaneados no micro-CT para determinação do volume remanescente inicial de material obturador, e posterior complementação com inserto ultrassônico (n = 7) ou XP-endo Finisher R (n = 7). Os espécimes foram novamente escaneados, e a partir do volume inicial de material obturador (volinicial) e volume de material obturador remanescente (volrem) em mm3, obteve-se a % de volume de material remanescente após as técnicas de complementação (%volrem=volrem×100/volinicial). Para a análise qualitativa, as imagens de MEV e os modelos tridimensionais obtidos por micro-CT, foram avaliados em relação à presença/ausência e localização do remanescente de material obturador nos canais radiculares. Os dados de %volrem e volume remanescente de material obturador após o uso do instrumento R50 (%volR50) foram comparados pelo teste T, e os dados de %volrem foram submetidos ao teste ANOVA, seguido de teste de Tukey (nível de probabilidade de 95%). Considerando o canal como um todo, as técnicas de complementação promoveram redução significativa do volume remanescente de material obturador, sendo que menores valores foram observados quando utilizado o inserto ultrassônico (8,93 ± 6,12) em relação ao XP-endo Finisher R (16,26 ± 14,71) (P = 0,043). Quanto aos cimentos, pode-se observar que o BC Sealer apresentou maiores quantidades de remanescente (18,87 ± 13,42) quando comparado ao cimento AH Plus (6,33 ± 4,25) (P < 0,001). Em relação à avaliação por terços radiculares, observou-se que quando utilizado o instrumento XP-endo Finisher R, não houve diferença do volume de material remanescente entre os terços, independente do cimento obturador utilizado (P > 0,05). Entretanto, ao se utilizar inserto ultrassônico e cimento AH Plus, maiores valores de volume de material remanescente foram observados no terço apical (23,08 ± 18,1) (P < 0,001), e quando utilizado o BC Sealer, no terço médio (15,53 ± 6,0) (P = 0,022). Conclui-se que as técnicas de complementação aumentaram a remoção de material obturador, entretanto, nenhuma das técnicas removeu por completo o material obturador do canal radicular, principalmente quando o dente foi obturado com o cimento BC Sealer
publishDate 2018
dc.date.none.fl_str_mv 2018-04-18
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/58/58133/tde-19092018-081259/
url http://www.teses.usp.br/teses/disponiveis/58/58133/tde-19092018-081259/
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1815257132307578880