Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata

Detalhes bibliográficos
Autor(a) principal: Feitosa, Marco Aurelio Alves
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da USP
Texto Completo: http://www.teses.usp.br/teses/disponiveis/23/23147/tde-13092012-115548/
Resumo: Os componentes protéticos que fazem a união entre implante e prótese são importantes para a manutenção da saúde peri-implantar sendo responsáveis pela vedação permucosa e impedindo a penetração de agentes químicos ou bacterianos desencadeadores de processos destrutivos nas estruturas ao redor do implante. Assim faz-se importante o desenvolvimento de técnicas que preservando as características de citocompatibilidade dos componentes protéticos que incorporem a sua estrutura, agentes antibacterianos que assegurem a saúde peri-implantar e que não permitam o desenvolvimento de resistência dos micro-organismos sendo ainda inócuos aos tecidos circunjacentes e ao organismo como um todo. Este trabalho teve o objetivo de testar a citocompatibilidade de discos de titânio com uma cobertura revestida usando nanotecnologia de prata em cultura de fibroblastos gengivais humanos. Discos de titânio de 5,9 mm foram preparados para o ensaio, sendo compostos por disco controle ST (N=1) sem nenhuma espécie de tratamento e disco com tratamento CT (N=3) com 3 camadas de cobertura com filme carregado com partículas de prata. O aditivo antimicrobiano à base de prata foi obtido pelo método wet chemistry por impregnação de metal homogeneamente distribuída sobre a superfície do disco. Fragmentos de gengiva foram cortados e colocados em placas de petri com meio de cultura Eagle modificado por Dulbecco. Com aproximadamente 15 dias foram retirados os fragmentos de gengiva, seguido da tripsinização das células para sua expansão. O meio de cultura foi trocado a cada 2-3 dias e a progressão da cultura foi avaliada por microscópio de fase. Os FGHs (fibroblastos de gengiva humana) na terceira passagem (p3) foram contados em um hemocitômetro e plaqueados em placas de 96 e 24 poços. As análises foram feitas com 24, 48 e 72 horas após o plaqueamento. Após a solubilização, as soluções foram transferidas para uma nova placa de 96 poços, e efetuada a leitura. A citotoxicidade dos materiais foi avaliada por espectrofotometria no aparelho Leitor de Elisa, com comprimento de onda de 590 nm. As amostras foram metalizadas e o MEV foi usado para avaliar a morfologia das células. O comportamento da cultura de fibroblastos sobre os discos de titânio em um período de 24 horas mostrou-se mais favorável na superfície ST mesmo após 48 horas quando CT apresentou valores inferiores ao ST, porém estatisticamente não significantes ao tempo de armazenamento. A avaliação após 72 horas indica que CT apresentou queda no desenvolvimento da cultura de fibroblastos em relação a ST sendo o resultado estatisticamente significante o que sugere menor característica de citocompatibilidade do material utilizado no tratamento de superfície que se potencializa com o aumento do tempo de exposição visto que quando comparado aos demais espécimes com meio de cultura com nutrientes (CC), controle sobre a superfície da placa em H2O sem nutrientes (H2O) e controle sobre a superfície da placa com meio de cultura com nutrientes acrescido de fenol a 1 % (CM) o espécime CT somente teve valores absolutos superiores para presença das células quando comparado ao espécime CM. Nossos dados indicaram a necessidade de se promover aperfeiçoamento no complexo estrutural do material de cobertura dos discos de forma que se tornem mais citocompatíveis.
id USP_4bbb2c0acdb7a16280c72481f0d15c7a
oai_identifier_str oai:teses.usp.br:tde-13092012-115548
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prataCytocompatibility of titanium disks treated using silver nanotechnologyCitocompatibilidadeCytocompatibilityFibroblastFibroblastoPrataSilverOs componentes protéticos que fazem a união entre implante e prótese são importantes para a manutenção da saúde peri-implantar sendo responsáveis pela vedação permucosa e impedindo a penetração de agentes químicos ou bacterianos desencadeadores de processos destrutivos nas estruturas ao redor do implante. Assim faz-se importante o desenvolvimento de técnicas que preservando as características de citocompatibilidade dos componentes protéticos que incorporem a sua estrutura, agentes antibacterianos que assegurem a saúde peri-implantar e que não permitam o desenvolvimento de resistência dos micro-organismos sendo ainda inócuos aos tecidos circunjacentes e ao organismo como um todo. Este trabalho teve o objetivo de testar a citocompatibilidade de discos de titânio com uma cobertura revestida usando nanotecnologia de prata em cultura de fibroblastos gengivais humanos. Discos de titânio de 5,9 mm foram preparados para o ensaio, sendo compostos por disco controle ST (N=1) sem nenhuma espécie de tratamento e disco com tratamento CT (N=3) com 3 camadas de cobertura com filme carregado com partículas de prata. O aditivo antimicrobiano à base de prata foi obtido pelo método wet chemistry por impregnação de metal homogeneamente distribuída sobre a superfície do disco. Fragmentos de gengiva foram cortados e colocados em placas de petri com meio de cultura Eagle modificado por Dulbecco. Com aproximadamente 15 dias foram retirados os fragmentos de gengiva, seguido da tripsinização das células para sua expansão. O meio de cultura foi trocado a cada 2-3 dias e a progressão da cultura foi avaliada por microscópio de fase. Os FGHs (fibroblastos de gengiva humana) na terceira passagem (p3) foram contados em um hemocitômetro e plaqueados em placas de 96 e 24 poços. As análises foram feitas com 24, 48 e 72 horas após o plaqueamento. Após a solubilização, as soluções foram transferidas para uma nova placa de 96 poços, e efetuada a leitura. A citotoxicidade dos materiais foi avaliada por espectrofotometria no aparelho Leitor de Elisa, com comprimento de onda de 590 nm. As amostras foram metalizadas e o MEV foi usado para avaliar a morfologia das células. O comportamento da cultura de fibroblastos sobre os discos de titânio em um período de 24 horas mostrou-se mais favorável na superfície ST mesmo após 48 horas quando CT apresentou valores inferiores ao ST, porém estatisticamente não significantes ao tempo de armazenamento. A avaliação após 72 horas indica que CT apresentou queda no desenvolvimento da cultura de fibroblastos em relação a ST sendo o resultado estatisticamente significante o que sugere menor característica de citocompatibilidade do material utilizado no tratamento de superfície que se potencializa com o aumento do tempo de exposição visto que quando comparado aos demais espécimes com meio de cultura com nutrientes (CC), controle sobre a superfície da placa em H2O sem nutrientes (H2O) e controle sobre a superfície da placa com meio de cultura com nutrientes acrescido de fenol a 1 % (CM) o espécime CT somente teve valores absolutos superiores para presença das células quando comparado ao espécime CM. Nossos dados indicaram a necessidade de se promover aperfeiçoamento no complexo estrutural do material de cobertura dos discos de forma que se tornem mais citocompatíveis.The prosthetic components that make the bond between implant and prosthesis are important for maintaining healthy peri-implant permucosal being responsible for sealing and preventing penetratíon of chemicals or bacterial triggers of destructive processes in the structures around the implant. So it is important to develop techniques that preserve the characteristics of cell compatibility of prosthetic components that incorporate its structure, antibacterial agents to ensure the peri-implant health and not allow the development of resistance of micro-organisms are harmless to the tissues even and surrounding the body as a whole. This study aimed to test the cell compatibility of titanium disks coated with a covering of silver using nanotechnology in cultured human gingival fibroblasts. Titanium disks of 5.9 mm were prepared for trial, being composed of hard control ST (N = 1) without any kind of treatment and treatment disc with CT (n = 3) with 3 layers of film cover loaded with silver particles. The additive antimicrobial silver-based was obtained by wet chemistry by impregnatíon of metal homogeneously distributed over the disk surface. Gingival fragments were distributed in petri dishes with culture medium Dulbecco\'s modified Eagle. With approximately 15 days they were removed, followed by trypsinizatíon of the cells for their expansíon. The culture medium were changed every 2-3 days of culture and progressíon was evaluated by phase microscopy. The FGHs (human gingival fibroblasts) in the third passage (p3) were counted in a hemocytometer and plated in a 96 and 24 wells. Analyses from 24, 48 and 72 hours after plating were made. After solubilizatíon, the solutíons were transferred to a new 96-well plate, and made reading. The cytotoxicity of the materials were evaluated by spectrophotometric ELISA reader device with a wavelength of 590 nm. The samples were metallized and SEM was used to assess cell morphology. The behavior of cultured fibroblasts on titanium disks in a period of 24 hours was more favorable on the surface of ST even after 48 hours when the CT were lower than the ST but not statistically significant at the time of storage. The evaluatíon afetr 72 hours indicates that the CT fell in the development of cultured fibroblasts in relatíon to the ST and the result was statistically significant which suggests lower cell compatibility characteristic of the material used in surface treatment that enhances with increasing time exposure as compared to other disk with culture medium with nutrients (CC), control over the surface of the plate without nutrients H2O and control over the surface of the plate with culture medium with nutrients plus phenol 1 % (CM) the CT only had higher absolute values for the presence of cells when compared to CM. Our data indicated the need to promote improvement in the structural complex of the covering material so that the disks become more compatibility.Biblioteca Digitais de Teses e Dissertações da USPSoares, Mario SergioFeitosa, Marco Aurelio Alves2012-04-27info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://www.teses.usp.br/teses/disponiveis/23/23147/tde-13092012-115548/reponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USPLiberar o conteúdo para acesso público.info:eu-repo/semantics/openAccesspor2016-07-28T16:10:32Zoai:teses.usp.br:tde-13092012-115548Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212016-07-28T16:10:32Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
Cytocompatibility of titanium disks treated using silver nanotechnology
title Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
spellingShingle Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
Feitosa, Marco Aurelio Alves
Citocompatibilidade
Cytocompatibility
Fibroblast
Fibroblasto
Prata
Silver
title_short Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
title_full Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
title_fullStr Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
title_full_unstemmed Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
title_sort Citocompatibilidade de discos de titânio tratados com cobertura usando nanotecnologia de prata
author Feitosa, Marco Aurelio Alves
author_facet Feitosa, Marco Aurelio Alves
author_role author
dc.contributor.none.fl_str_mv Soares, Mario Sergio
dc.contributor.author.fl_str_mv Feitosa, Marco Aurelio Alves
dc.subject.por.fl_str_mv Citocompatibilidade
Cytocompatibility
Fibroblast
Fibroblasto
Prata
Silver
topic Citocompatibilidade
Cytocompatibility
Fibroblast
Fibroblasto
Prata
Silver
description Os componentes protéticos que fazem a união entre implante e prótese são importantes para a manutenção da saúde peri-implantar sendo responsáveis pela vedação permucosa e impedindo a penetração de agentes químicos ou bacterianos desencadeadores de processos destrutivos nas estruturas ao redor do implante. Assim faz-se importante o desenvolvimento de técnicas que preservando as características de citocompatibilidade dos componentes protéticos que incorporem a sua estrutura, agentes antibacterianos que assegurem a saúde peri-implantar e que não permitam o desenvolvimento de resistência dos micro-organismos sendo ainda inócuos aos tecidos circunjacentes e ao organismo como um todo. Este trabalho teve o objetivo de testar a citocompatibilidade de discos de titânio com uma cobertura revestida usando nanotecnologia de prata em cultura de fibroblastos gengivais humanos. Discos de titânio de 5,9 mm foram preparados para o ensaio, sendo compostos por disco controle ST (N=1) sem nenhuma espécie de tratamento e disco com tratamento CT (N=3) com 3 camadas de cobertura com filme carregado com partículas de prata. O aditivo antimicrobiano à base de prata foi obtido pelo método wet chemistry por impregnação de metal homogeneamente distribuída sobre a superfície do disco. Fragmentos de gengiva foram cortados e colocados em placas de petri com meio de cultura Eagle modificado por Dulbecco. Com aproximadamente 15 dias foram retirados os fragmentos de gengiva, seguido da tripsinização das células para sua expansão. O meio de cultura foi trocado a cada 2-3 dias e a progressão da cultura foi avaliada por microscópio de fase. Os FGHs (fibroblastos de gengiva humana) na terceira passagem (p3) foram contados em um hemocitômetro e plaqueados em placas de 96 e 24 poços. As análises foram feitas com 24, 48 e 72 horas após o plaqueamento. Após a solubilização, as soluções foram transferidas para uma nova placa de 96 poços, e efetuada a leitura. A citotoxicidade dos materiais foi avaliada por espectrofotometria no aparelho Leitor de Elisa, com comprimento de onda de 590 nm. As amostras foram metalizadas e o MEV foi usado para avaliar a morfologia das células. O comportamento da cultura de fibroblastos sobre os discos de titânio em um período de 24 horas mostrou-se mais favorável na superfície ST mesmo após 48 horas quando CT apresentou valores inferiores ao ST, porém estatisticamente não significantes ao tempo de armazenamento. A avaliação após 72 horas indica que CT apresentou queda no desenvolvimento da cultura de fibroblastos em relação a ST sendo o resultado estatisticamente significante o que sugere menor característica de citocompatibilidade do material utilizado no tratamento de superfície que se potencializa com o aumento do tempo de exposição visto que quando comparado aos demais espécimes com meio de cultura com nutrientes (CC), controle sobre a superfície da placa em H2O sem nutrientes (H2O) e controle sobre a superfície da placa com meio de cultura com nutrientes acrescido de fenol a 1 % (CM) o espécime CT somente teve valores absolutos superiores para presença das células quando comparado ao espécime CM. Nossos dados indicaram a necessidade de se promover aperfeiçoamento no complexo estrutural do material de cobertura dos discos de forma que se tornem mais citocompatíveis.
publishDate 2012
dc.date.none.fl_str_mv 2012-04-27
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.teses.usp.br/teses/disponiveis/23/23147/tde-13092012-115548/
url http://www.teses.usp.br/teses/disponiveis/23/23147/tde-13092012-115548/
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv
dc.rights.driver.fl_str_mv Liberar o conteúdo para acesso público.
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Liberar o conteúdo para acesso público.
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv
dc.publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
publisher.none.fl_str_mv Biblioteca Digitais de Teses e Dissertações da USP
dc.source.none.fl_str_mv
reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1815256943648833536