Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200006 |
Resumo: | PURPOSE: To evaluate the distance, intermediate and near visual acuity of patients with bilateral cataract operated on both eyes corrected for distance in one eye and for near in the fellow eye, as well as, their stereo acuity and their general satisfaction. SETTINGS: Hospital de Olhos de São Paulo and Complexo Hospitalar Padre Bento - Guarulhos - São Paulo - Brazil. METHODS: This is a prospective study of 76 eyes of 38 patients with bilateral cataract aiming to become spectacle free after surgery. The patients were operated on both eyes; the first eye was corrected for distance and the fellow eye for near vision. The refractive error was programmed between -0.5 D and +0.5 D in the first eye and -2.00 D in the second eye. Patients with preoperative corneal astigmatism equal or higher than 1.0 D were excluded from the study. The uncorrected and best-corrected distant visual acuity (UCDVA, BCDVA) were tested, as well as the uncorrected near visual acuity (UCNVA) and collected at the 3 postoperative months. The Titmus test was performed at the last follow-up. Finally, the modified questionnaire VF-7 was applied and the patient was required to choose, regarding their general satisfaction, between very satisfied, satisfied, or unsatisfied. RESULTS: All patients achieved uncorrected distant visual acuity 20/40 or better (mean SE 0.625 D) and uncorrected near visual acuity J3 or better (mean SE -2.0 D), and intermediate visual acuity J3 in 90%. The Titmus test revealed an average of 197" of arc with reduction of stereo acuity in most of patients as expected and 97.3% of patients demonstrated to be satisfied or very satisfied with this technique. CONCLUSION: It consists in a viable technique for correction of near, intermediate and distant vision on cataract surgery as demonstrated by the high rate of satisfaction (97.3%) by the modified VF-7 questionnaire, especially when the patient has no access to a multifocal intraocular lens. |
id |
CBO-2_9c127505d256fd99d3560dcd25a33304 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492009000200006 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision techniqueCataract extractionRefraction, ocularLens implantation, intraocularPhacoemulsificationVisual acuityVision testsPatient satisfactionPURPOSE: To evaluate the distance, intermediate and near visual acuity of patients with bilateral cataract operated on both eyes corrected for distance in one eye and for near in the fellow eye, as well as, their stereo acuity and their general satisfaction. SETTINGS: Hospital de Olhos de São Paulo and Complexo Hospitalar Padre Bento - Guarulhos - São Paulo - Brazil. METHODS: This is a prospective study of 76 eyes of 38 patients with bilateral cataract aiming to become spectacle free after surgery. The patients were operated on both eyes; the first eye was corrected for distance and the fellow eye for near vision. The refractive error was programmed between -0.5 D and +0.5 D in the first eye and -2.00 D in the second eye. Patients with preoperative corneal astigmatism equal or higher than 1.0 D were excluded from the study. The uncorrected and best-corrected distant visual acuity (UCDVA, BCDVA) were tested, as well as the uncorrected near visual acuity (UCNVA) and collected at the 3 postoperative months. The Titmus test was performed at the last follow-up. Finally, the modified questionnaire VF-7 was applied and the patient was required to choose, regarding their general satisfaction, between very satisfied, satisfied, or unsatisfied. RESULTS: All patients achieved uncorrected distant visual acuity 20/40 or better (mean SE 0.625 D) and uncorrected near visual acuity J3 or better (mean SE -2.0 D), and intermediate visual acuity J3 in 90%. The Titmus test revealed an average of 197" of arc with reduction of stereo acuity in most of patients as expected and 97.3% of patients demonstrated to be satisfied or very satisfied with this technique. CONCLUSION: It consists in a viable technique for correction of near, intermediate and distant vision on cataract surgery as demonstrated by the high rate of satisfaction (97.3%) by the modified VF-7 questionnaire, especially when the patient has no access to a multifocal intraocular lens.Conselho Brasileiro de Oftalmologia2009-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200006Arquivos Brasileiros de Oftalmologia v.72 n.2 2009reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492009000200006info:eu-repo/semantics/openAccessMarques,Frederico FrançaSato,Ricardo MitsuoChiacchio,Brenda BiagioMarques,Daniela Meira VillanoBarreiro,JefersonCaetano,Renato Lucioeng2009-05-12T00:00:00Zoai:scielo:S0004-27492009000200006Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2009-05-12T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
title |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
spellingShingle |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique Marques,Frederico França Cataract extraction Refraction, ocular Lens implantation, intraocular Phacoemulsification Visual acuity Vision tests Patient satisfaction |
title_short |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
title_full |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
title_fullStr |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
title_full_unstemmed |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
title_sort |
Evaluation of visual performance and patient satisfaction with pseudophakic monovision technique |
author |
Marques,Frederico França |
author_facet |
Marques,Frederico França Sato,Ricardo Mitsuo Chiacchio,Brenda Biagio Marques,Daniela Meira Villano Barreiro,Jeferson Caetano,Renato Lucio |
author_role |
author |
author2 |
Sato,Ricardo Mitsuo Chiacchio,Brenda Biagio Marques,Daniela Meira Villano Barreiro,Jeferson Caetano,Renato Lucio |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Marques,Frederico França Sato,Ricardo Mitsuo Chiacchio,Brenda Biagio Marques,Daniela Meira Villano Barreiro,Jeferson Caetano,Renato Lucio |
dc.subject.por.fl_str_mv |
Cataract extraction Refraction, ocular Lens implantation, intraocular Phacoemulsification Visual acuity Vision tests Patient satisfaction |
topic |
Cataract extraction Refraction, ocular Lens implantation, intraocular Phacoemulsification Visual acuity Vision tests Patient satisfaction |
description |
PURPOSE: To evaluate the distance, intermediate and near visual acuity of patients with bilateral cataract operated on both eyes corrected for distance in one eye and for near in the fellow eye, as well as, their stereo acuity and their general satisfaction. SETTINGS: Hospital de Olhos de São Paulo and Complexo Hospitalar Padre Bento - Guarulhos - São Paulo - Brazil. METHODS: This is a prospective study of 76 eyes of 38 patients with bilateral cataract aiming to become spectacle free after surgery. The patients were operated on both eyes; the first eye was corrected for distance and the fellow eye for near vision. The refractive error was programmed between -0.5 D and +0.5 D in the first eye and -2.00 D in the second eye. Patients with preoperative corneal astigmatism equal or higher than 1.0 D were excluded from the study. The uncorrected and best-corrected distant visual acuity (UCDVA, BCDVA) were tested, as well as the uncorrected near visual acuity (UCNVA) and collected at the 3 postoperative months. The Titmus test was performed at the last follow-up. Finally, the modified questionnaire VF-7 was applied and the patient was required to choose, regarding their general satisfaction, between very satisfied, satisfied, or unsatisfied. RESULTS: All patients achieved uncorrected distant visual acuity 20/40 or better (mean SE 0.625 D) and uncorrected near visual acuity J3 or better (mean SE -2.0 D), and intermediate visual acuity J3 in 90%. The Titmus test revealed an average of 197" of arc with reduction of stereo acuity in most of patients as expected and 97.3% of patients demonstrated to be satisfied or very satisfied with this technique. CONCLUSION: It consists in a viable technique for correction of near, intermediate and distant vision on cataract surgery as demonstrated by the high rate of satisfaction (97.3%) by the modified VF-7 questionnaire, especially when the patient has no access to a multifocal intraocular lens. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200006 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492009000200006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492009000200006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.72 n.2 2009 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209025579286528 |