Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000400225 |
Resumo: | Abstract Objective: To evaluate cerebrospinal fluid dynamics, using cine phase-contrast magnetic resonance imaging (cine-PC MRI), in healthy pediatric subjects, determining the normal flow values in this population, as well as identifying differences related to age, sex, and body surface area. Materials and Methods: This was a descriptive cross-sectional study involving 32 healthy children and adolescents, in whom the flow of cerebrospinal fluid through the cerebral aqueduct was evaluated quantitatively with cine-PC MRI. We used specialized software to analyze the images obtained with cine-PC MRI, drawing a region of interest on the aqueduct. A flow-time curve was obtained, as were automated measurements of the various parameters. Results: The following normal (mean) values were obtained: net flow, 1.10 ± 0.99 mL/m; stroke volume, 12.2 ± 10.1 μL/cycle; mean velocity, 0.72 ± 1.00 cm/s; peak systolic velocity, 5.28 ± 2.30 cm/s; peak diastolic velocity, 4.51 ± 1.77 cm/s. These values were not affected by age or sex. In addition, body surface area was not found to correlate significantly with mean velocity or stroke volume. Conclusion: In children and adolescents, the basic cerebrospinal fluid flow parameters, as determined by cine-PC MRI, appear to be independent of age and sex. |
id |
CBR-1_d6b3145fd5ebba3e728cc07cd05f0f69 |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842022000400225 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjectsCerebrospinal fluidMagnetic resonance imaging, cineCerebral aqueductHydrodynamicsAbstract Objective: To evaluate cerebrospinal fluid dynamics, using cine phase-contrast magnetic resonance imaging (cine-PC MRI), in healthy pediatric subjects, determining the normal flow values in this population, as well as identifying differences related to age, sex, and body surface area. Materials and Methods: This was a descriptive cross-sectional study involving 32 healthy children and adolescents, in whom the flow of cerebrospinal fluid through the cerebral aqueduct was evaluated quantitatively with cine-PC MRI. We used specialized software to analyze the images obtained with cine-PC MRI, drawing a region of interest on the aqueduct. A flow-time curve was obtained, as were automated measurements of the various parameters. Results: The following normal (mean) values were obtained: net flow, 1.10 ± 0.99 mL/m; stroke volume, 12.2 ± 10.1 μL/cycle; mean velocity, 0.72 ± 1.00 cm/s; peak systolic velocity, 5.28 ± 2.30 cm/s; peak diastolic velocity, 4.51 ± 1.77 cm/s. These values were not affected by age or sex. In addition, body surface area was not found to correlate significantly with mean velocity or stroke volume. Conclusion: In children and adolescents, the basic cerebrospinal fluid flow parameters, as determined by cine-PC MRI, appear to be independent of age and sex.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2022-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000400225Radiologia Brasileira v.55 n.4 2022reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2021.0120info:eu-repo/semantics/openAccessPlata,Karen SousaCruz,GerardoLezcano,Hectoreng2022-08-11T00:00:00Zoai:scielo:S0100-39842022000400225Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2022-08-11T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
title |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
spellingShingle |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects Plata,Karen Sousa Cerebrospinal fluid Magnetic resonance imaging, cine Cerebral aqueduct Hydrodynamics |
title_short |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
title_full |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
title_fullStr |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
title_full_unstemmed |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
title_sort |
Cine phase-contrast magnetic resonance imaging evaluation of cerebrospinal fluid flow dynamics in healthy pediatric subjects |
author |
Plata,Karen Sousa |
author_facet |
Plata,Karen Sousa Cruz,Gerardo Lezcano,Hector |
author_role |
author |
author2 |
Cruz,Gerardo Lezcano,Hector |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Plata,Karen Sousa Cruz,Gerardo Lezcano,Hector |
dc.subject.por.fl_str_mv |
Cerebrospinal fluid Magnetic resonance imaging, cine Cerebral aqueduct Hydrodynamics |
topic |
Cerebrospinal fluid Magnetic resonance imaging, cine Cerebral aqueduct Hydrodynamics |
description |
Abstract Objective: To evaluate cerebrospinal fluid dynamics, using cine phase-contrast magnetic resonance imaging (cine-PC MRI), in healthy pediatric subjects, determining the normal flow values in this population, as well as identifying differences related to age, sex, and body surface area. Materials and Methods: This was a descriptive cross-sectional study involving 32 healthy children and adolescents, in whom the flow of cerebrospinal fluid through the cerebral aqueduct was evaluated quantitatively with cine-PC MRI. We used specialized software to analyze the images obtained with cine-PC MRI, drawing a region of interest on the aqueduct. A flow-time curve was obtained, as were automated measurements of the various parameters. Results: The following normal (mean) values were obtained: net flow, 1.10 ± 0.99 mL/m; stroke volume, 12.2 ± 10.1 μL/cycle; mean velocity, 0.72 ± 1.00 cm/s; peak systolic velocity, 5.28 ± 2.30 cm/s; peak diastolic velocity, 4.51 ± 1.77 cm/s. These values were not affected by age or sex. In addition, body surface area was not found to correlate significantly with mean velocity or stroke volume. Conclusion: In children and adolescents, the basic cerebrospinal fluid flow parameters, as determined by cine-PC MRI, appear to be independent of age and sex. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000400225 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000400225 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-3984.2021.0120 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.55 n.4 2022 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208941254901760 |