Change in crown inclination accompanying initial tooth alignment with round archwires
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Dental Press Journal of Orthodontics |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307 |
Resumo: | ABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics. |
id |
DPI-1_393fe8e59d553c5c1ad0549e05c57559 |
---|---|
oai_identifier_str |
oai:scielo:S2176-94512022000300307 |
network_acronym_str |
DPI-1 |
network_name_str |
Dental Press Journal of Orthodontics |
repository_id_str |
|
spelling |
Change in crown inclination accompanying initial tooth alignment with round archwiresInclinationTooth alignmentOrthodontic archwiresOrthodontic bracketsABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics.Dental Press International2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307Dental Press Journal of Orthodontics v.27 n.3 2022reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.27.3.e2220489.oarinfo:eu-repo/semantics/openAccessMONTASSER,Mona A.KEILIG,LudgerBOURAUEL,Christopheng2022-07-01T00:00:00Zoai:scielo:S2176-94512022000300307Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2022-07-01T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false |
dc.title.none.fl_str_mv |
Change in crown inclination accompanying initial tooth alignment with round archwires |
title |
Change in crown inclination accompanying initial tooth alignment with round archwires |
spellingShingle |
Change in crown inclination accompanying initial tooth alignment with round archwires MONTASSER,Mona A. Inclination Tooth alignment Orthodontic archwires Orthodontic brackets |
title_short |
Change in crown inclination accompanying initial tooth alignment with round archwires |
title_full |
Change in crown inclination accompanying initial tooth alignment with round archwires |
title_fullStr |
Change in crown inclination accompanying initial tooth alignment with round archwires |
title_full_unstemmed |
Change in crown inclination accompanying initial tooth alignment with round archwires |
title_sort |
Change in crown inclination accompanying initial tooth alignment with round archwires |
author |
MONTASSER,Mona A. |
author_facet |
MONTASSER,Mona A. KEILIG,Ludger BOURAUEL,Christoph |
author_role |
author |
author2 |
KEILIG,Ludger BOURAUEL,Christoph |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
MONTASSER,Mona A. KEILIG,Ludger BOURAUEL,Christoph |
dc.subject.por.fl_str_mv |
Inclination Tooth alignment Orthodontic archwires Orthodontic brackets |
topic |
Inclination Tooth alignment Orthodontic archwires Orthodontic brackets |
description |
ABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2177-6709.27.3.e2220489.oar |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
Dental Press Journal of Orthodontics v.27 n.3 2022 reponame:Dental Press Journal of Orthodontics instname:Dental Press International (DPI) instacron:DPI |
instname_str |
Dental Press International (DPI) |
instacron_str |
DPI |
institution |
DPI |
reponame_str |
Dental Press Journal of Orthodontics |
collection |
Dental Press Journal of Orthodontics |
repository.name.fl_str_mv |
Dental Press Journal of Orthodontics - Dental Press International (DPI) |
repository.mail.fl_str_mv |
artigos@dentalpress.com.br||davidnormando@hotmail.com |
_version_ |
1754122399139233792 |