Portal Vein Dopplerflowmetry in healthy sheep according to age

Detalhes bibliográficos
Autor(a) principal: Belotta,Alexandra F.
Data de Publicação: 2017
Outros Autores: Santarosa,Bianca P., Ferreira,Danilo O.L., Carvalho,Sílvia M.F., Gonçalves,Roberto C., Padovani,Carlos R., Mamprim,Maria J.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Pesquisa Veterinária Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2017001001172
Resumo: ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes), according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05). Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01). Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.
id EMBRAPA-2_5e4dd087b6fe6144f22ed5ce5b49825e
oai_identifier_str oai:scielo:S0100-736X2017001001172
network_acronym_str EMBRAPA-2
network_name_str Pesquisa Veterinária Brasileira (Online)
repository_id_str
spelling Portal Vein Dopplerflowmetry in healthy sheep according to agePortal Vein DopplerflowmetryDopplerliverportal veinsheepultrasonography.ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes), according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05). Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01). Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.Colégio Brasileiro de Patologia Animal - CBPA2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2017001001172Pesquisa Veterinária Brasileira v.37 n.10 2017reponame:Pesquisa Veterinária Brasileira (Online)instname:Colégio Brasileiro de Patologia Animal (CBPA)instacron:EMBRAPA10.1590/s0100-736x2017001000021info:eu-repo/semantics/openAccessBelotta,Alexandra F.Santarosa,Bianca P.Ferreira,Danilo O.L.Carvalho,Sílvia M.F.Gonçalves,Roberto C.Padovani,Carlos R.Mamprim,Maria J.eng2018-01-12T00:00:00Zoai:scielo:S0100-736X2017001001172Revistahttp://www.pvb.com.br/https://old.scielo.br/oai/scielo-oai.phpcolegio@cbpa.org.br||pvb@pvb.com.br0100-736X1678-5150opendoar:2018-01-12T00:00Pesquisa Veterinária Brasileira (Online) - Colégio Brasileiro de Patologia Animal (CBPA)false
dc.title.none.fl_str_mv Portal Vein Dopplerflowmetry in healthy sheep according to age
title Portal Vein Dopplerflowmetry in healthy sheep according to age
spellingShingle Portal Vein Dopplerflowmetry in healthy sheep according to age
Belotta,Alexandra F.
Portal Vein Dopplerflowmetry
Doppler
liver
portal vein
sheep
ultrasonography.
title_short Portal Vein Dopplerflowmetry in healthy sheep according to age
title_full Portal Vein Dopplerflowmetry in healthy sheep according to age
title_fullStr Portal Vein Dopplerflowmetry in healthy sheep according to age
title_full_unstemmed Portal Vein Dopplerflowmetry in healthy sheep according to age
title_sort Portal Vein Dopplerflowmetry in healthy sheep according to age
author Belotta,Alexandra F.
author_facet Belotta,Alexandra F.
Santarosa,Bianca P.
Ferreira,Danilo O.L.
Carvalho,Sílvia M.F.
Gonçalves,Roberto C.
Padovani,Carlos R.
Mamprim,Maria J.
author_role author
author2 Santarosa,Bianca P.
Ferreira,Danilo O.L.
Carvalho,Sílvia M.F.
Gonçalves,Roberto C.
Padovani,Carlos R.
Mamprim,Maria J.
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Belotta,Alexandra F.
Santarosa,Bianca P.
Ferreira,Danilo O.L.
Carvalho,Sílvia M.F.
Gonçalves,Roberto C.
Padovani,Carlos R.
Mamprim,Maria J.
dc.subject.por.fl_str_mv Portal Vein Dopplerflowmetry
Doppler
liver
portal vein
sheep
ultrasonography.
topic Portal Vein Dopplerflowmetry
Doppler
liver
portal vein
sheep
ultrasonography.
description ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes), according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05). Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01). Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.
publishDate 2017
dc.date.none.fl_str_mv 2017-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2017001001172
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2017001001172
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s0100-736x2017001000021
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Colégio Brasileiro de Patologia Animal - CBPA
publisher.none.fl_str_mv Colégio Brasileiro de Patologia Animal - CBPA
dc.source.none.fl_str_mv Pesquisa Veterinária Brasileira v.37 n.10 2017
reponame:Pesquisa Veterinária Brasileira (Online)
instname:Colégio Brasileiro de Patologia Animal (CBPA)
instacron:EMBRAPA
instname_str Colégio Brasileiro de Patologia Animal (CBPA)
instacron_str EMBRAPA
institution EMBRAPA
reponame_str Pesquisa Veterinária Brasileira (Online)
collection Pesquisa Veterinária Brasileira (Online)
repository.name.fl_str_mv Pesquisa Veterinária Brasileira (Online) - Colégio Brasileiro de Patologia Animal (CBPA)
repository.mail.fl_str_mv colegio@cbpa.org.br||pvb@pvb.com.br
_version_ 1754122237509632000