Resumo: | This work describes the development and evaluation of a biosensor designed for enzymatic detection of short-chain alcohols, using an X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The biorecognition element, alcohol dehydrogenase, was immobilized on self-assembled monolayers deposited on top of silicon nitride microcantilevers. Biosensor assays provided detection of short-chain alcohols and evaluation of the infuence of a biological element immobilization on the analytical performance of the device. The self-assembly process was performed by surface activation using 3-aminopropyltriethoxysilane, followed by glutaraldehyde and biomolecule binding. XPS and AFM were used to verify surface oxidation and reagent binding. The biosensor showed a response time shorter than 1 s, a total renovation of the bioactive layer after 10 min, a sensibility from 0.03 to 1.2 mL/L, and a lifetime of 22 days. Its selectivity was analyzed through exposure to pure and mixed volatile solvents. Sensor sensibility was higher in the presence of short-chain alcohols family (methanol, ethanol, and propanol) ranging from 0.45 to 0.85 kHz and practically null involving other polar or nonpolar solvents. The biosensor showed less susceptibility to humidity and temperature variations, presenting a high-quality factor, a faster response time, selectivity, sensitivity, and durability. |
id |
EMBR_a9b9b14fa9b60c77b1748c22c067a80a |
---|---|
oai_identifier_str |
oai:www.alice.cnptia.embrapa.br:doc/1143406 |
network_acronym_str |
EMBR |
network_name_str |
Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) |
repository_id_str |
2154 |
spelling |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor.BiosensorGas detectorShort-chain alcoholsXPSMicrocantileverThis work describes the development and evaluation of a biosensor designed for enzymatic detection of short-chain alcohols, using an X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The biorecognition element, alcohol dehydrogenase, was immobilized on self-assembled monolayers deposited on top of silicon nitride microcantilevers. Biosensor assays provided detection of short-chain alcohols and evaluation of the infuence of a biological element immobilization on the analytical performance of the device. The self-assembly process was performed by surface activation using 3-aminopropyltriethoxysilane, followed by glutaraldehyde and biomolecule binding. XPS and AFM were used to verify surface oxidation and reagent binding. The biosensor showed a response time shorter than 1 s, a total renovation of the bioactive layer after 10 min, a sensibility from 0.03 to 1.2 mL/L, and a lifetime of 22 days. Its selectivity was analyzed through exposure to pure and mixed volatile solvents. Sensor sensibility was higher in the presence of short-chain alcohols family (methanol, ethanol, and propanol) ranging from 0.45 to 0.85 kHz and practically null involving other polar or nonpolar solvents. The biosensor showed less susceptibility to humidity and temperature variations, presenting a high-quality factor, a faster response time, selectivity, sensitivity, and durability.PAULO SERGIO DE P HERRMANN JUNIOR, CNPDIA.MARGARIDO, A.MANZINE, L. R.ARAÚJO-MOREIRA, F. M.GONÇALVES, R. V.HERRMANN JUNIOR, P. S. de P.2024-01-24T11:27:04Z2024-01-24T11:27:04Z2022-05-242022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article14 p.Brazilian Journal of Physics, v. 52, 112, 2022.http://www.alice.cnptia.embrapa.br/alice/handle/doc/114340610.1007/s13538-022-01111-wenginfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa)instacron:EMBRAPA2024-01-24T11:27:04Zoai:www.alice.cnptia.embrapa.br:doc/1143406Repositório InstitucionalPUBhttps://www.alice.cnptia.embrapa.br/oai/requestopendoar:21542024-01-24T11:27:04falseRepositório InstitucionalPUBhttps://www.alice.cnptia.embrapa.br/oai/requestcg-riaa@embrapa.bropendoar:21542024-01-24T11:27:04Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa)false |
dc.title.none.fl_str_mv |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
title |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
spellingShingle |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. MARGARIDO, A. Biosensor Gas detector Short-chain alcohols XPS Microcantilever |
title_short |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
title_full |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
title_fullStr |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
title_full_unstemmed |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
title_sort |
Specific detection of short-chain alcohols, with the development of an enzyme-coated microcantilever-based biosensor. |
author |
MARGARIDO, A. |
author_facet |
MARGARIDO, A. MANZINE, L. R. ARAÚJO-MOREIRA, F. M. GONÇALVES, R. V. HERRMANN JUNIOR, P. S. de P. |
author_role |
author |
author2 |
MANZINE, L. R. ARAÚJO-MOREIRA, F. M. GONÇALVES, R. V. HERRMANN JUNIOR, P. S. de P. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
PAULO SERGIO DE P HERRMANN JUNIOR, CNPDIA. |
dc.contributor.author.fl_str_mv |
MARGARIDO, A. MANZINE, L. R. ARAÚJO-MOREIRA, F. M. GONÇALVES, R. V. HERRMANN JUNIOR, P. S. de P. |
dc.subject.por.fl_str_mv |
Biosensor Gas detector Short-chain alcohols XPS Microcantilever |
topic |
Biosensor Gas detector Short-chain alcohols XPS Microcantilever |
description |
This work describes the development and evaluation of a biosensor designed for enzymatic detection of short-chain alcohols, using an X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The biorecognition element, alcohol dehydrogenase, was immobilized on self-assembled monolayers deposited on top of silicon nitride microcantilevers. Biosensor assays provided detection of short-chain alcohols and evaluation of the infuence of a biological element immobilization on the analytical performance of the device. The self-assembly process was performed by surface activation using 3-aminopropyltriethoxysilane, followed by glutaraldehyde and biomolecule binding. XPS and AFM were used to verify surface oxidation and reagent binding. The biosensor showed a response time shorter than 1 s, a total renovation of the bioactive layer after 10 min, a sensibility from 0.03 to 1.2 mL/L, and a lifetime of 22 days. Its selectivity was analyzed through exposure to pure and mixed volatile solvents. Sensor sensibility was higher in the presence of short-chain alcohols family (methanol, ethanol, and propanol) ranging from 0.45 to 0.85 kHz and practically null involving other polar or nonpolar solvents. The biosensor showed less susceptibility to humidity and temperature variations, presenting a high-quality factor, a faster response time, selectivity, sensitivity, and durability. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-05-24 2022 2024-01-24T11:27:04Z 2024-01-24T11:27:04Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Brazilian Journal of Physics, v. 52, 112, 2022. http://www.alice.cnptia.embrapa.br/alice/handle/doc/1143406 10.1007/s13538-022-01111-w |
identifier_str_mv |
Brazilian Journal of Physics, v. 52, 112, 2022. 10.1007/s13538-022-01111-w |
url |
http://www.alice.cnptia.embrapa.br/alice/handle/doc/1143406 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
14 p. |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa) instacron:EMBRAPA |
instname_str |
Empresa Brasileira de Pesquisa Agropecuária (Embrapa) |
instacron_str |
EMBRAPA |
institution |
EMBRAPA |
reponame_str |
Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) |
collection |
Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) |
repository.name.fl_str_mv |
Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa) |
repository.mail.fl_str_mv |
cg-riaa@embrapa.br |
_version_ |
1794503556192010240 |