Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins

Detalhes bibliográficos
Autor(a) principal: Consani,Rafael Leonardo Xediek
Data de Publicação: 2009
Outros Autores: Azevedo,Douglas Duenhas de, Mesquita,Marcelo Ferraz, Mendes,Wilson Batista, Saquy,Paulo César
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000200008
Resumo: The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.
id FUNORP-1_d1fb5350422edcb43d732488f646ea8b
oai_identifier_str oai:scielo:S0103-64402009000200008
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resinshardnessimpactflexural strengthacrylic resinmicrowave disinfectionThe present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.Fundação Odontológica de Ribeirão Preto2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000200008Brazilian Dental Journal v.20 n.2 2009reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402009000200008info:eu-repo/semantics/openAccessConsani,Rafael Leonardo XediekAzevedo,Douglas Duenhas deMesquita,Marcelo FerrazMendes,Wilson BatistaSaquy,Paulo Césareng2009-09-08T00:00:00Zoai:scielo:S0103-64402009000200008Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2009-09-08T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
title Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
spellingShingle Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
Consani,Rafael Leonardo Xediek
hardness
impact
flexural strength
acrylic resin
microwave disinfection
title_short Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
title_full Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
title_fullStr Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
title_full_unstemmed Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
title_sort Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins
author Consani,Rafael Leonardo Xediek
author_facet Consani,Rafael Leonardo Xediek
Azevedo,Douglas Duenhas de
Mesquita,Marcelo Ferraz
Mendes,Wilson Batista
Saquy,Paulo César
author_role author
author2 Azevedo,Douglas Duenhas de
Mesquita,Marcelo Ferraz
Mendes,Wilson Batista
Saquy,Paulo César
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Consani,Rafael Leonardo Xediek
Azevedo,Douglas Duenhas de
Mesquita,Marcelo Ferraz
Mendes,Wilson Batista
Saquy,Paulo César
dc.subject.por.fl_str_mv hardness
impact
flexural strength
acrylic resin
microwave disinfection
topic hardness
impact
flexural strength
acrylic resin
microwave disinfection
description The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000200008
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000200008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402009000200008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.20 n.2 2009
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090959659008