Polymerization shrinkage stress of composites photoactivated by different light sources

Detalhes bibliográficos
Autor(a) principal: Pires de Souza,Fernanda de Carvalho Panzeri
Data de Publicação: 2009
Outros Autores: Drubi Filho,Brahim, Casemiro,Luciana Assirati, Garcia,Lucas da Fonseca Roberti, Consani,Simonides
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400010
Resumo: The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.
id FUNORP-1_d7279e9fa2e3df9a43aad22d1ece2358
oai_identifier_str oai:scielo:S0103-64402009000400010
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Polymerization shrinkage stress of composites photoactivated by different light sourcescompositephotoactivationshrinkage stresshalogen lightLEDThe purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.Fundação Odontológica de Ribeirão Preto2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400010Brazilian Dental Journal v.20 n.4 2009reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402009000400010info:eu-repo/semantics/openAccessPires de Souza,Fernanda de Carvalho PanzeriDrubi Filho,BrahimCasemiro,Luciana AssiratiGarcia,Lucas da Fonseca RobertiConsani,Simonideseng2009-12-17T00:00:00Zoai:scielo:S0103-64402009000400010Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2009-12-17T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Polymerization shrinkage stress of composites photoactivated by different light sources
title Polymerization shrinkage stress of composites photoactivated by different light sources
spellingShingle Polymerization shrinkage stress of composites photoactivated by different light sources
Pires de Souza,Fernanda de Carvalho Panzeri
composite
photoactivation
shrinkage stress
halogen light
LED
title_short Polymerization shrinkage stress of composites photoactivated by different light sources
title_full Polymerization shrinkage stress of composites photoactivated by different light sources
title_fullStr Polymerization shrinkage stress of composites photoactivated by different light sources
title_full_unstemmed Polymerization shrinkage stress of composites photoactivated by different light sources
title_sort Polymerization shrinkage stress of composites photoactivated by different light sources
author Pires de Souza,Fernanda de Carvalho Panzeri
author_facet Pires de Souza,Fernanda de Carvalho Panzeri
Drubi Filho,Brahim
Casemiro,Luciana Assirati
Garcia,Lucas da Fonseca Roberti
Consani,Simonides
author_role author
author2 Drubi Filho,Brahim
Casemiro,Luciana Assirati
Garcia,Lucas da Fonseca Roberti
Consani,Simonides
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Pires de Souza,Fernanda de Carvalho Panzeri
Drubi Filho,Brahim
Casemiro,Luciana Assirati
Garcia,Lucas da Fonseca Roberti
Consani,Simonides
dc.subject.por.fl_str_mv composite
photoactivation
shrinkage stress
halogen light
LED
topic composite
photoactivation
shrinkage stress
halogen light
LED
description The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402009000400010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.20 n.4 2009
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091266891776