DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de gastroenterologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000300316 |
Resumo: | ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence. |
id |
IBEPEGE-1_d8732a875ae4a008c2226863aa3845af |
---|---|
oai_identifier_str |
oai:scielo:S0004-28032020000300316 |
network_acronym_str |
IBEPEGE-1 |
network_name_str |
Arquivos de gastroenterologia (Online) |
repository_id_str |
|
spelling |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTIONColorectal neoplasms, diagnosisIntestinal polypsPredictive value of testsOccult bloodColonoscopyABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. 2020-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000300316Arquivos de Gastroenterologia v.57 n.3 2020reponame:Arquivos de gastroenterologia (Online)instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiainstacron:IBEPEGE10.1590/s0004-2803.202000000-58info:eu-repo/semantics/openAccessMATTAR,RejaneMARQUES,Sergio BarbosaMINATA,Maurício KazuyoshiSILVA-ETTO,Joyce Matie Kinoshita daSAKAI,PauloDE MOURA,Eduardo Guimarães Hourneauxeng2020-11-09T00:00:00Zoai:scielo:S0004-28032020000300316Revistahttp://www.scielo.br/aghttps://old.scielo.br/oai/scielo-oai.php||secretariaarqgastr@hospitaligesp.com.br1678-42190004-2803opendoar:2020-11-09T00:00Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiafalse |
dc.title.none.fl_str_mv |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
title |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
spellingShingle |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION MATTAR,Rejane Colorectal neoplasms, diagnosis Intestinal polyps Predictive value of tests Occult blood Colonoscopy |
title_short |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
title_full |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
title_fullStr |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
title_full_unstemmed |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
title_sort |
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION |
author |
MATTAR,Rejane |
author_facet |
MATTAR,Rejane MARQUES,Sergio Barbosa MINATA,Maurício Kazuyoshi SILVA-ETTO,Joyce Matie Kinoshita da SAKAI,Paulo DE MOURA,Eduardo Guimarães Hourneaux |
author_role |
author |
author2 |
MARQUES,Sergio Barbosa MINATA,Maurício Kazuyoshi SILVA-ETTO,Joyce Matie Kinoshita da SAKAI,Paulo DE MOURA,Eduardo Guimarães Hourneaux |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
MATTAR,Rejane MARQUES,Sergio Barbosa MINATA,Maurício Kazuyoshi SILVA-ETTO,Joyce Matie Kinoshita da SAKAI,Paulo DE MOURA,Eduardo Guimarães Hourneaux |
dc.subject.por.fl_str_mv |
Colorectal neoplasms, diagnosis Intestinal polyps Predictive value of tests Occult blood Colonoscopy |
topic |
Colorectal neoplasms, diagnosis Intestinal polyps Predictive value of tests Occult blood Colonoscopy |
description |
ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000300316 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032020000300316 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s0004-2803.202000000-58 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
dc.source.none.fl_str_mv |
Arquivos de Gastroenterologia v.57 n.3 2020 reponame:Arquivos de gastroenterologia (Online) instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia instacron:IBEPEGE |
instname_str |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
instacron_str |
IBEPEGE |
institution |
IBEPEGE |
reponame_str |
Arquivos de gastroenterologia (Online) |
collection |
Arquivos de gastroenterologia (Online) |
repository.name.fl_str_mv |
Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
repository.mail.fl_str_mv |
||secretariaarqgastr@hospitaligesp.com.br |
_version_ |
1754193350270910464 |