Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , , , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Digital do Instituto Evandro Chagas (Patuá) |
DOI: | 10.3390/diagnostics13040810. |
Texto Completo: | https://patua.iec.gov.br/handle/iec/6739 |
Resumo: | We field-assessed the accuracy, acceptability, and feasibility of the SD BIOLINE HIV/Syphilis Duo rapid diagnostic test in three groups: pregnant women, female sex workers (FSW), and men who have sex with men (MSM). Venous blood samples collected in the field were compared with the respective gold standard methods: SD BIOLINE HIV/Syphilis Duo Treponemal Test versus FTA-abs (Wama brand) treponemal laboratory test for syphilis, and SD BIOLINE HIV/Syphilis Duo Test versus the fourth generation Genscreen Ultra HIV Ag-Ag (Bio-Rad brand) laboratory test for HIV. From a total of 529 participants, 397 (75.1%) were pregnant women, 76 (14.3%) FSW and 56 (10.6%) MSM. Sensitivity and specificity parameters of HIV were 100.0% (95% CI: 82.35–100.0%) and 100.0% (95% CI: 99.28–100.0%), respectively. Sensitivity and specificity parameters found for TP antibody detection were 95.00% (95% CI: 87.69–98.62%) and 100.0% (95% CI: 98.18–100.0%), respectively. The SD BIOLINE HIV/Syphilis Duo Test showed high acceptability among participants (85.87%) and health professionals (85.51%), as well as easy usability by professionals (91.06%). The usability of the SD BIOLINE HIV/Syphilis Duo Test kit would not be a barrier to accessing rapid testing, if the product were incorporated into the list of health service supplies. |
id |
IEC-2_644a2eeff7d3b7c27bd0d913e05bedc4 |
---|---|
oai_identifier_str |
oai:patua.iec.gov.br:iec/6739 |
network_acronym_str |
IEC-2 |
network_name_str |
Repositório Digital do Instituto Evandro Chagas (Patuá) |
spelling |
Soares, Daniela CristinaFranco Filho, Luciano ChavesReis, Herald Souza dosRodrigues, Yan CorrêaFreitas, Felipe BonfimSouza, Cintya de OliveiraDamacena, Giseli NogueiraVéras, Nazle Mendonça CollaçoGaspar, Pamela CristinaBenzaken, Adele SchwartzFavacho, Joana da Felicidade RibeiroMacêdo, OlindaBazzo, Maria Luiza2023-03-14T12:58:37Z2023-03-14T12:58:37Z2023SOARES, Daniela Cristina et al. Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil. Diagnostics, v. 13, n. 4, p. 1-11, 2023. DOI: https://doi.org/10.3390/diagnostics13040810.2075-4418https://patua.iec.gov.br/handle/iec/673910.3390/diagnostics13040810We field-assessed the accuracy, acceptability, and feasibility of the SD BIOLINE HIV/Syphilis Duo rapid diagnostic test in three groups: pregnant women, female sex workers (FSW), and men who have sex with men (MSM). Venous blood samples collected in the field were compared with the respective gold standard methods: SD BIOLINE HIV/Syphilis Duo Treponemal Test versus FTA-abs (Wama brand) treponemal laboratory test for syphilis, and SD BIOLINE HIV/Syphilis Duo Test versus the fourth generation Genscreen Ultra HIV Ag-Ag (Bio-Rad brand) laboratory test for HIV. From a total of 529 participants, 397 (75.1%) were pregnant women, 76 (14.3%) FSW and 56 (10.6%) MSM. Sensitivity and specificity parameters of HIV were 100.0% (95% CI: 82.35–100.0%) and 100.0% (95% CI: 99.28–100.0%), respectively. Sensitivity and specificity parameters found for TP antibody detection were 95.00% (95% CI: 87.69–98.62%) and 100.0% (95% CI: 98.18–100.0%), respectively. The SD BIOLINE HIV/Syphilis Duo Test showed high acceptability among participants (85.87%) and health professionals (85.51%), as well as easy usability by professionals (91.06%). The usability of the SD BIOLINE HIV/Syphilis Duo Test kit would not be a barrier to accessing rapid testing, if the product were incorporated into the list of health service supplies.This study was funded through Letter Agreement TC 66–SCON2019-00400 between the Pan American Health Organization (PAHO/WHO) and the Department of Chronic Diseases and Sexually Transmitted Infections—DCCI/SVS/MS, with the aim of support the national response to HIV/AIDS, Syphilis and other STIs and Viral HepatitisMinistério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Retrovírus. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Oswaldo Cruz Foundation. Institute of Scientific and Technological Communication and Information in Health. Rio de Janeiro, RJ, Brazil.Ministry of Health. Department of Diseases of Chronic Condition and Sexually Transmitted Infections. Brasilia, DF, Brazil.Ministry of Health. Department of Diseases of Chronic Condition and Sexually Transmitted Infections. Brasilia, DF, Brazil.Oswaldo Cruz Foundation. Manaus, AM, Brazil / AIDS Healthcare Foudation. Los Angeles, CA, USA.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Infecções Sexualmente Transmissíveis. Ananindeua, PA, Brasil.Ministério da Saúde. Secretaria de Vigilância em Saúde e Ambiente. Instituto Evandro Chagas. Laboratório de Retrovírus. Ananindeua, PA, Brasil.Federal University of Santa Catarina. Center for Health Sciences. Graduate Program in Pharmacy. Florianópolis, SC, Brazil.engMDPIAssessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazilinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleHIV / diagnósticoSífilis / diagnósticoTeste de HIVTestes ImediatosSensibilidade e EspecificidadeSD Bioline HIV/Syphilis DuoRegião Amazônica (BR)info:eu-repo/semantics/openAccessreponame:Repositório Digital do Instituto Evandro Chagas (Patuá)instname:Instituto Evandro Chagas (IEC)instacron:IECORIGINAL Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdf Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdfapplication/pdf681502https://patua.iec.gov.br/bitstreams/e45a4fed-502a-4b26-a175-b149b38ee7c5/downloada433575cfbc8a524ee9de1867671f825MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-82182https://patua.iec.gov.br/bitstreams/59398963-fd9b-477d-993f-cc946e1e8cfb/download11832eea31b16df8613079d742d61793MD52TEXTdiagnostics-13-00810-v2.pdf.txtdiagnostics-13-00810-v2.pdf.txtExtracted texttext/plain47621https://patua.iec.gov.br/bitstreams/3c64ebab-abb8-4368-b416-6ae1149994d7/download25ad529154e9de2f04041bf882930cb6MD53Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdf.txtAssessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdf.txtExtracted texttext/plain47621https://patua.iec.gov.br/bitstreams/3febc310-a33a-455a-b165-0c79973b4c84/download25ad529154e9de2f04041bf882930cb6MD55THUMBNAILdiagnostics-13-00810-v2.pdf.jpgdiagnostics-13-00810-v2.pdf.jpgGenerated Thumbnailimage/jpeg5948https://patua.iec.gov.br/bitstreams/aa67b2e1-a280-4abd-8dac-3ba09cb391d1/download5cb57484b333a91ef4e6c7eb415001adMD54Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdf.jpgAssessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil.pdf.jpgGenerated Thumbnailimage/jpeg5948https://patua.iec.gov.br/bitstreams/9bdc50aa-25f8-475c-9e78-4427b892fddd/download5cb57484b333a91ef4e6c7eb415001adMD56iec/67392023-03-22 11:52:25.013oai:patua.iec.gov.br:iec/6739https://patua.iec.gov.brRepositório InstitucionalPUBhttps://patua.iec.gov.br/oai/requestclariceneta@iec.gov.br || Biblioteca@iec.gov.bropendoar:2023-03-22T11:52:25Repositório Digital do Instituto Evandro Chagas (Patuá) - Instituto Evandro Chagas (IEC)falsePGI+TGljZW7Dp2EgZGUgRGlzdHJpYnVpw6fDo28gTsOjbyBFeGNsdXNpdmE8L2I+DQoNClRvZG8gZGVwb3NpdGFudGUgZGUgbWF0ZXJpYWwgbm8gUGF0dcOhIGRldmUgY29uY2VkZXIgYW8gSW5zdGl0dXRvIEV2YW5kcm8gQ2hhZ2FzIHVtYSBMaWNlbsOnYSBkZSBEaXN0cmlidWnDp8OjbyBOw6NvIEV4Y2x1c2l2YSBwYXJhIHRvcm5hciBlIG1hbnRlciBhY2Vzc8OtdmVpcyBvcyBzZXVzIGRvY3VtZW50b3MgZW0gZm9ybWF0byBkaWdpdGFsLiANCg0KQ29tIGEgY29uY2Vzc8OjbyBkZXNzYSBsaWNlbsOnYSBuw6NvIGV4Y2x1c2l2YSwgbyBkZXBvc2l0YW50ZSBjb250aW51YSBhIHJldGVyIHRvZG9zIG9zIGRpcmVpdG9zIGRlIGF1dG9yLg0KDQpBbyBhc3NpbmFyIGUgZW50cmVnYXIgZXN0YSBsaWNlbsOnYSB2b2PDqiAoYXV0b3Igb3UgZGV0ZW50b3IgZG9zIGRpcmVpdG9zIGF1dG9yYWlzKQ0KDQphKSBEZWNsYXJhIHF1ZSBjb25oZWNlIGEgcG9sw610aWNhIGRlIGNvcHlyaWdodCBkYSBlZGl0b3JhIGRlIHNldSBkb2N1bWVudG8uDQoNCmIpIENvbmNlZGUgYW8gSW5zdGl0dXRvIEV2YW5kcm8gQ2hhZ2FzIG8gZGlyZWl0byBuw6NvIGV4Y2x1c2l2byBkZSBhcnF1aXZhciwgcmVwcm9kdXppciwgY29udmVydGVyIChjb21vIGRlZmluaWRvIGEgc2VndWlyKSwgY29tdW5pY2FyIGUvb3UgZGlzdHJpYnVpciBubyA8Yj5QYXR1w6E8L2I+LCBvIGRvY3VtZW50byBlbnRyZWd1ZSAoaW5jbHVpbmRvIG8gcmVzdW1vL2Fic3RyYWN0KSBlbSBmb3JtYXRvIGRpZ2l0YWwgb3UgcG9yIHF1YWxxdWVyIG91dHJvIG1laW8uDQoNCmMpIERlY2xhcmEgcXVlIGF1dG9yaXphIG8gSW5zdGl0dXRvIEV2YW5kcm8gQ2hhZ2FzIGEgYXJxdWl2YXIgbWFpcyBkZSB1bWEgY8OzcGlhIGRlc3NlIGRvY3VtZW50byBlIGNvbnZlcnTDqi1sbywgc2VtIGFsdGVyYXIgbyBzZXUgY29udGXDumRvLCBwYXJhIHF1YWxxdWVyIGZvcm1hdG8gZGUgZmljaGVpcm8sIG1laW8gb3Ugc3Vwb3J0ZSwgcGFyYSBlZmVpdG9zIGRlIHNlZ3VyYW7Dp2EsIHByZXNlcnZhw6fDo28gKGJhY2t1cCkgZSBhY2Vzc28uDQoNCmQpIERlY2xhcmEgcXVlIG8gZG9jdW1lbnRvIHN1Ym1ldGlkbyDDqSBvIHNldSB0cmFiYWxobyBvcmlnaW5hbCBlIHF1ZSBkZXTDqW0gbyBkaXJlaXRvIGRlIGNvbmNlZGVyIGEgdGVyY2Vpcm9zIG9zIGRpcmVpdG9zIGNvbnRpZG9zIG5lc3RhIGxpY2Vuw6dhLiBEZWNsYXJhIHRhbWLDqW0gcXVlIGEgZW50cmVnYSBkbyBkb2N1bWVudG8gbsOjbyBpbmZyaW5nZSBvcyBkaXJlaXRvcyBkZSBxdWFscXVlciBvdXRyYSBwZXNzb2Egb3UgZW50aWRhZGUuDQoNCmUpIERlY2xhcmEgcXVlLCBubyBjYXNvIGRvIGRvY3VtZW50byBzdWJtZXRpZG8gY29udGVyIG1hdGVyaWFsIGRvIHF1YWwgbsOjbyBkZXTDqW0gb3MgZGlyZWl0b3MgZGUgYXV0b3IsIG9idGV2ZSBhIGF1dG9yaXphw6fDo28gaXJyZXN0cml0YSBkbyByZXNwZWN0aXZvIGRldGVudG9yIGRlc3NlcyBkaXJlaXRvcywgcGFyYSBjZWRlciBhbyBJbnN0aXR1dG8gRXZhbmRybyBDaGFnYXMgb3MgZGlyZWl0b3MgcmVxdWVyaWRvcyBwb3IgZXN0YSBMaWNlbsOnYSBlIGF1dG9yaXphciBhIHV0aWxpesOhLWxvcyBsZWdhbG1lbnRlLiBEZWNsYXJhIHRhbWLDqW0gcXVlIGVzc2UgbWF0ZXJpYWwgY3Vqb3MgZGlyZWl0b3Mgc8OjbyBkZSB0ZXJjZWlyb3MgZXN0w6EgY2xhcmFtZW50ZSBpZGVudGlmaWNhZG8gZSByZWNvbmhlY2lkbyBubyB0ZXh0byBvdSBjb250ZcO6ZG8gZG8gZG9jdW1lbnRvIGVudHJlZ3VlLg0KDQpmKSBTRSBPIERPQ1VNRU5UTyBFTlRSRUdVRSBGT1IgQkFTRUFETyBFTSBUUkFCQUxITyBGSU5BTkNJQURPIE9VIEFQT0lBRE8gUE9SIE9VVFJBIElOU1RJVFVJw4fDg08gUVVFIE7Dg08gTyBJTlNUSVRVVE8gRVZBTkRSTyBDSEFHQVMsIERFQ0xBUkEgUVVFIENVTVBSSVUgUVVBSVNRVUVSIE9CUklHQcOHw5VFUyBFWElHSURBUyBQRUxPIFJFU1BFQ1RJVk8gQ09OVFJBVE8gT1UgQUNPUkRPLg0KDQpPIEluc3RpdHV0byBFdmFuZHJvIENoYWdhcyBpZGVudGlmaWNhcsOhIGNsYXJhbWVudGUgbyhzKSBub21lKHMpIGRvKHMpIGF1dG9yKGVzKSBkb3MgZGlyZWl0b3MgZG8gZG9jdW1lbnRvIGVudHJlZ3VlIGUgbsOjbyBmYXLDoSBxdWFscXVlciBhbHRlcmHDp8OjbyBhbMOpbSBkbyBwcmV2aXN0byBuYSBhbMOtbmVhIGIpLg== |
dc.title.pt_BR.fl_str_mv |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
title |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
spellingShingle |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil Soares, Daniela Cristina HIV / diagnóstico Sífilis / diagnóstico Teste de HIV Testes Imediatos Sensibilidade e Especificidade SD Bioline HIV/Syphilis Duo Região Amazônica (BR) Soares, Daniela Cristina HIV / diagnóstico Sífilis / diagnóstico Teste de HIV Testes Imediatos Sensibilidade e Especificidade SD Bioline HIV/Syphilis Duo Região Amazônica (BR) |
title_short |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
title_full |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
title_fullStr |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
title_full_unstemmed |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
title_sort |
Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil |
author |
Soares, Daniela Cristina |
author_facet |
Soares, Daniela Cristina Soares, Daniela Cristina Franco Filho, Luciano Chaves Reis, Herald Souza dos Rodrigues, Yan Corrêa Freitas, Felipe Bonfim Souza, Cintya de Oliveira Damacena, Giseli Nogueira Véras, Nazle Mendonça Collaço Gaspar, Pamela Cristina Benzaken, Adele Schwartz Favacho, Joana da Felicidade Ribeiro Macêdo, Olinda Bazzo, Maria Luiza Franco Filho, Luciano Chaves Reis, Herald Souza dos Rodrigues, Yan Corrêa Freitas, Felipe Bonfim Souza, Cintya de Oliveira Damacena, Giseli Nogueira Véras, Nazle Mendonça Collaço Gaspar, Pamela Cristina Benzaken, Adele Schwartz Favacho, Joana da Felicidade Ribeiro Macêdo, Olinda Bazzo, Maria Luiza |
author_role |
author |
author2 |
Franco Filho, Luciano Chaves Reis, Herald Souza dos Rodrigues, Yan Corrêa Freitas, Felipe Bonfim Souza, Cintya de Oliveira Damacena, Giseli Nogueira Véras, Nazle Mendonça Collaço Gaspar, Pamela Cristina Benzaken, Adele Schwartz Favacho, Joana da Felicidade Ribeiro Macêdo, Olinda Bazzo, Maria Luiza |
author2_role |
author author author author author author author author author author author author |
dc.contributor.author.fl_str_mv |
Soares, Daniela Cristina Franco Filho, Luciano Chaves Reis, Herald Souza dos Rodrigues, Yan Corrêa Freitas, Felipe Bonfim Souza, Cintya de Oliveira Damacena, Giseli Nogueira Véras, Nazle Mendonça Collaço Gaspar, Pamela Cristina Benzaken, Adele Schwartz Favacho, Joana da Felicidade Ribeiro Macêdo, Olinda Bazzo, Maria Luiza |
dc.subject.decsPrimary.pt_BR.fl_str_mv |
HIV / diagnóstico Sífilis / diagnóstico Teste de HIV Testes Imediatos Sensibilidade e Especificidade SD Bioline HIV/Syphilis Duo Região Amazônica (BR) |
topic |
HIV / diagnóstico Sífilis / diagnóstico Teste de HIV Testes Imediatos Sensibilidade e Especificidade SD Bioline HIV/Syphilis Duo Região Amazônica (BR) |
description |
We field-assessed the accuracy, acceptability, and feasibility of the SD BIOLINE HIV/Syphilis Duo rapid diagnostic test in three groups: pregnant women, female sex workers (FSW), and men who have sex with men (MSM). Venous blood samples collected in the field were compared with the respective gold standard methods: SD BIOLINE HIV/Syphilis Duo Treponemal Test versus FTA-abs (Wama brand) treponemal laboratory test for syphilis, and SD BIOLINE HIV/Syphilis Duo Test versus the fourth generation Genscreen Ultra HIV Ag-Ag (Bio-Rad brand) laboratory test for HIV. From a total of 529 participants, 397 (75.1%) were pregnant women, 76 (14.3%) FSW and 56 (10.6%) MSM. Sensitivity and specificity parameters of HIV were 100.0% (95% CI: 82.35–100.0%) and 100.0% (95% CI: 99.28–100.0%), respectively. Sensitivity and specificity parameters found for TP antibody detection were 95.00% (95% CI: 87.69–98.62%) and 100.0% (95% CI: 98.18–100.0%), respectively. The SD BIOLINE HIV/Syphilis Duo Test showed high acceptability among participants (85.87%) and health professionals (85.51%), as well as easy usability by professionals (91.06%). The usability of the SD BIOLINE HIV/Syphilis Duo Test kit would not be a barrier to accessing rapid testing, if the product were incorporated into the list of health service supplies. |
publishDate |
2023 |
dc.date.accessioned.fl_str_mv |
2023-03-14T12:58:37Z |
dc.date.available.fl_str_mv |
2023-03-14T12:58:37Z |
dc.date.issued.fl_str_mv |
2023 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
SOARES, Daniela Cristina et al. Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil. Diagnostics, v. 13, n. 4, p. 1-11, 2023. DOI: https://doi.org/10.3390/diagnostics13040810. |
dc.identifier.uri.fl_str_mv |
https://patua.iec.gov.br/handle/iec/6739 |
dc.identifier.issn.-.fl_str_mv |
2075-4418 |
dc.identifier.doi.pt_BR.fl_str_mv |
10.3390/diagnostics13040810 |
identifier_str_mv |
SOARES, Daniela Cristina et al. Assessment of the accuracy, usability and acceptability of a rapid test for the simultaneous diagnosis of syphilis and HIV infection in a real-life scenario in the Amazon Region, Brazil. Diagnostics, v. 13, n. 4, p. 1-11, 2023. DOI: https://doi.org/10.3390/diagnostics13040810. 2075-4418 10.3390/diagnostics13040810 |
url |
https://patua.iec.gov.br/handle/iec/6739 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
MDPI |
publisher.none.fl_str_mv |
MDPI |
dc.source.none.fl_str_mv |
reponame:Repositório Digital do Instituto Evandro Chagas (Patuá) instname:Instituto Evandro Chagas (IEC) instacron:IEC |
instname_str |
Instituto Evandro Chagas (IEC) |
instacron_str |
IEC |
institution |
IEC |
reponame_str |
Repositório Digital do Instituto Evandro Chagas (Patuá) |
collection |
Repositório Digital do Instituto Evandro Chagas (Patuá) |
bitstream.url.fl_str_mv |
https://patua.iec.gov.br/bitstreams/e45a4fed-502a-4b26-a175-b149b38ee7c5/download https://patua.iec.gov.br/bitstreams/59398963-fd9b-477d-993f-cc946e1e8cfb/download https://patua.iec.gov.br/bitstreams/3c64ebab-abb8-4368-b416-6ae1149994d7/download https://patua.iec.gov.br/bitstreams/3febc310-a33a-455a-b165-0c79973b4c84/download https://patua.iec.gov.br/bitstreams/aa67b2e1-a280-4abd-8dac-3ba09cb391d1/download https://patua.iec.gov.br/bitstreams/9bdc50aa-25f8-475c-9e78-4427b892fddd/download |
bitstream.checksum.fl_str_mv |
a433575cfbc8a524ee9de1867671f825 11832eea31b16df8613079d742d61793 25ad529154e9de2f04041bf882930cb6 25ad529154e9de2f04041bf882930cb6 5cb57484b333a91ef4e6c7eb415001ad 5cb57484b333a91ef4e6c7eb415001ad |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Digital do Instituto Evandro Chagas (Patuá) - Instituto Evandro Chagas (IEC) |
repository.mail.fl_str_mv |
clariceneta@iec.gov.br || Biblioteca@iec.gov.br |
_version_ |
1822222149866225664 |
dc.identifier.doi.none.fl_str_mv |
10.3390/diagnostics13040810. |