The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista do Instituto de Medicina Tropical de São Paulo |
Texto Completo: | https://www.revistas.usp.br/rimtsp/article/view/172367 |
Resumo: | Simple, low-cost and effective diagnostic tests for tuberculosis (TB) are needed especially in TB-high burden settings. The present study evaluated the performance of an in-house loop-mediated isothermal amplification (LAMP) for diagnosing TB by comparing it to Xpert MTB/RIF, microscopy and culture. In Thailand, a total of 204 excess sputum samples volume after the processing of cultures were used for Mycobacterium tuberculosis (MTB) detection by Xpert MTB/RIF and LAMP. Based on culture results as the gold standard, the overall sensitivity of LAMP and Xpert MTB/RIF were 82.1% (126/153; 95% confidential interval [CI]: 75.4-88.98%) and 86.9 % (133/153; 95% CI: 80.5-90.8%) respectively, and the specificity of both tests was 100% (51/51; 95% CI: 93.0-100.0%). In comparison with Xpert MTB/RIF, the sensitivity and specificity of LAMP were 94.7% (126/133; 95% CI: 89.5-97.9%), and 100.0% (73/73; 95% CI: 94.9-100.0%), respectively. The average threshold cycle (Ct) of Xpert MTB/RIF detection for positive and negative LAMP results was statistically different, of 18.4 and 27.0, respectively (p < 0.05). In comparison with the acid-fast staining technique, and analyzing LAMP and Xpert MTB/RIF in smear-negative/ culture-positive specimens, there was an increase of the detection rate by 47.7% (21/44) and 54.6% (24/44). The diagnostic sensitivity and specificity of LAMP appeared to be comparable to those of Xpert MTB/RIF. We claim that this LAMP has potential to provide a sensitive diagnostic test for the rapid TB diagnosis. It allowed a fast detection of MTB before the cultures and it could be used in resource-limited laboratory settings. |
id |
IMT-1_010bcf3b37a34fc330465889b00bc28f |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/172367 |
network_acronym_str |
IMT-1 |
network_name_str |
Revista do Instituto de Medicina Tropical de São Paulo |
repository_id_str |
|
spelling |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and cultureLAMPTuberculosisDiagnosisSputumSimple, low-cost and effective diagnostic tests for tuberculosis (TB) are needed especially in TB-high burden settings. The present study evaluated the performance of an in-house loop-mediated isothermal amplification (LAMP) for diagnosing TB by comparing it to Xpert MTB/RIF, microscopy and culture. In Thailand, a total of 204 excess sputum samples volume after the processing of cultures were used for Mycobacterium tuberculosis (MTB) detection by Xpert MTB/RIF and LAMP. Based on culture results as the gold standard, the overall sensitivity of LAMP and Xpert MTB/RIF were 82.1% (126/153; 95% confidential interval [CI]: 75.4-88.98%) and 86.9 % (133/153; 95% CI: 80.5-90.8%) respectively, and the specificity of both tests was 100% (51/51; 95% CI: 93.0-100.0%). In comparison with Xpert MTB/RIF, the sensitivity and specificity of LAMP were 94.7% (126/133; 95% CI: 89.5-97.9%), and 100.0% (73/73; 95% CI: 94.9-100.0%), respectively. The average threshold cycle (Ct) of Xpert MTB/RIF detection for positive and negative LAMP results was statistically different, of 18.4 and 27.0, respectively (p < 0.05). In comparison with the acid-fast staining technique, and analyzing LAMP and Xpert MTB/RIF in smear-negative/ culture-positive specimens, there was an increase of the detection rate by 47.7% (21/44) and 54.6% (24/44). The diagnostic sensitivity and specificity of LAMP appeared to be comparable to those of Xpert MTB/RIF. We claim that this LAMP has potential to provide a sensitive diagnostic test for the rapid TB diagnosis. It allowed a fast detection of MTB before the cultures and it could be used in resource-limited laboratory settings.Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo2020-07-13info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/xmlhttps://www.revistas.usp.br/rimtsp/article/view/17236710.1590/s1678-9946202062036Revista do Instituto de Medicina Tropical de São Paulo; Vol. 62 (2020); e36Revista do Instituto de Medicina Tropical de São Paulo; Vol. 62 (2020); e36Revista do Instituto de Medicina Tropical de São Paulo; v. 62 (2020); e361678-99460036-4665reponame:Revista do Instituto de Medicina Tropical de São Pauloinstname:Instituto de Medicina Tropical (IMT)instacron:IMTenghttps://www.revistas.usp.br/rimtsp/article/view/172367/161985https://www.revistas.usp.br/rimtsp/article/view/172367/161986Copyright (c) 2020 Revista do Instituto de Medicina Tropical de São Pauloinfo:eu-repo/semantics/openAccessPhetsuksiri, BenjawanKlayut, WiphatRudeeaneksin, JanisaraSrisungngam, SopaBunchoo, SupraneeToonkomdang, SarawutWongchai, ThaneeNakajima, ChieSuzuki, Yasuhiko2020-10-26T17:39:25Zoai:revistas.usp.br:article/172367Revistahttp://www.revistas.usp.br/rimtsp/indexPUBhttps://www.revistas.usp.br/rimtsp/oai||revimtsp@usp.br1678-99460036-4665opendoar:2022-12-13T16:52:52.606616Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT)true |
dc.title.none.fl_str_mv |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
title |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
spellingShingle |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture Phetsuksiri, Benjawan LAMP Tuberculosis Diagnosis Sputum |
title_short |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
title_full |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
title_fullStr |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
title_full_unstemmed |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
title_sort |
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture |
author |
Phetsuksiri, Benjawan |
author_facet |
Phetsuksiri, Benjawan Klayut, Wiphat Rudeeaneksin, Janisara Srisungngam, Sopa Bunchoo, Supranee Toonkomdang, Sarawut Wongchai, Thanee Nakajima, Chie Suzuki, Yasuhiko |
author_role |
author |
author2 |
Klayut, Wiphat Rudeeaneksin, Janisara Srisungngam, Sopa Bunchoo, Supranee Toonkomdang, Sarawut Wongchai, Thanee Nakajima, Chie Suzuki, Yasuhiko |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Phetsuksiri, Benjawan Klayut, Wiphat Rudeeaneksin, Janisara Srisungngam, Sopa Bunchoo, Supranee Toonkomdang, Sarawut Wongchai, Thanee Nakajima, Chie Suzuki, Yasuhiko |
dc.subject.por.fl_str_mv |
LAMP Tuberculosis Diagnosis Sputum |
topic |
LAMP Tuberculosis Diagnosis Sputum |
description |
Simple, low-cost and effective diagnostic tests for tuberculosis (TB) are needed especially in TB-high burden settings. The present study evaluated the performance of an in-house loop-mediated isothermal amplification (LAMP) for diagnosing TB by comparing it to Xpert MTB/RIF, microscopy and culture. In Thailand, a total of 204 excess sputum samples volume after the processing of cultures were used for Mycobacterium tuberculosis (MTB) detection by Xpert MTB/RIF and LAMP. Based on culture results as the gold standard, the overall sensitivity of LAMP and Xpert MTB/RIF were 82.1% (126/153; 95% confidential interval [CI]: 75.4-88.98%) and 86.9 % (133/153; 95% CI: 80.5-90.8%) respectively, and the specificity of both tests was 100% (51/51; 95% CI: 93.0-100.0%). In comparison with Xpert MTB/RIF, the sensitivity and specificity of LAMP were 94.7% (126/133; 95% CI: 89.5-97.9%), and 100.0% (73/73; 95% CI: 94.9-100.0%), respectively. The average threshold cycle (Ct) of Xpert MTB/RIF detection for positive and negative LAMP results was statistically different, of 18.4 and 27.0, respectively (p < 0.05). In comparison with the acid-fast staining technique, and analyzing LAMP and Xpert MTB/RIF in smear-negative/ culture-positive specimens, there was an increase of the detection rate by 47.7% (21/44) and 54.6% (24/44). The diagnostic sensitivity and specificity of LAMP appeared to be comparable to those of Xpert MTB/RIF. We claim that this LAMP has potential to provide a sensitive diagnostic test for the rapid TB diagnosis. It allowed a fast detection of MTB before the cultures and it could be used in resource-limited laboratory settings. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-07-13 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/172367 10.1590/s1678-9946202062036 |
url |
https://www.revistas.usp.br/rimtsp/article/view/172367 |
identifier_str_mv |
10.1590/s1678-9946202062036 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/172367/161985 https://www.revistas.usp.br/rimtsp/article/view/172367/161986 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2020 Revista do Instituto de Medicina Tropical de São Paulo info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2020 Revista do Instituto de Medicina Tropical de São Paulo |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/xml |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
dc.source.none.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo; Vol. 62 (2020); e36 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 62 (2020); e36 Revista do Instituto de Medicina Tropical de São Paulo; v. 62 (2020); e36 1678-9946 0036-4665 reponame:Revista do Instituto de Medicina Tropical de São Paulo instname:Instituto de Medicina Tropical (IMT) instacron:IMT |
instname_str |
Instituto de Medicina Tropical (IMT) |
instacron_str |
IMT |
institution |
IMT |
reponame_str |
Revista do Instituto de Medicina Tropical de São Paulo |
collection |
Revista do Instituto de Medicina Tropical de São Paulo |
repository.name.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT) |
repository.mail.fl_str_mv |
||revimtsp@usp.br |
_version_ |
1798951652698357760 |