Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por eng spa |
Título da fonte: | Revista Brasileira de Cancerologia (Online) |
DOI: | 10.32635/2176-9745.RBC.2023v69n3.4020 |
Texto Completo: | https://rbc.inca.gov.br/index.php/revista/article/view/4020 |
Resumo: | Introduction: Radiotherapy is utilized to treat breast cancer. For radiotherapy planning, there are several ways to develop the treatment plan, such as 3D conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Objective: To compare the doses to risk organs and treatment target volume with different planning techniques, 3D-CRT, IMRT, VMAT and modified VMAT for the treatment of breast cancer in an anthropomorphic phantom. Method: The treatment plan was performed in the Eclipse™ v.15.6 system by Varian from CT images acquired from phantom. The established prescription dose was 45 Gy in 25 fractions of 1.8Gy/day. Results: For the planning target volume (PTV) coverage, 3D-CRT techniques (FILTER and field-in-field – FIF) showed inferior coverage compared to IMRT and VMAT plans. The 3D-CRT-FIF plan, on the other hand, shows greater homogeneity when compared to 3D-CRT-FILTER. For the contralateral lung, the 3D-CRT plans (FIF, FILTER) have better restrictions when compared with the other plans. On cardiac exposure, the 3D-CRT (FIF, FILTER) plans showed greater benefits when compared with IMRT, VMAT and Modified VMAT techniques. Conclusion: Conventional 3D-CRT techniques (FIF, FILTER) showed lower doses in organs at risk. However, IMRT and VMAT techniques obtained better homogeneity and conformity of the dose delivered to the PTV when compared to conventional techniques. |
id |
INCA-1_cd61b681ec8720b00ba7ca50487a0c50 |
---|---|
oai_identifier_str |
oai:rbc.inca.gov.br:article/4020 |
network_acronym_str |
INCA-1 |
network_name_str |
Revista Brasileira de Cancerologia (Online) |
spelling |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast CancerComparación Dosimétrica entre Técnicas de Planificación de Radioterapia para el Cáncer de Mama IzquierdoComparação Dosimétrica entre Técnicas de Planejamento de Radioterapia para Câncer de Mama Esquerdaradioterapia conformacionalradioterapia de intensidade moduladaneoplasias da mamadoses de radiaçãoradiotherapy, conformalradiotherapy, intensity-modulatedbreast neoplasmsradiation dosageradioterapia conformacionalradioterapia de intensidad moduladaneoplasias de la mamadosis de radiaciónIntroduction: Radiotherapy is utilized to treat breast cancer. For radiotherapy planning, there are several ways to develop the treatment plan, such as 3D conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Objective: To compare the doses to risk organs and treatment target volume with different planning techniques, 3D-CRT, IMRT, VMAT and modified VMAT for the treatment of breast cancer in an anthropomorphic phantom. Method: The treatment plan was performed in the Eclipse™ v.15.6 system by Varian from CT images acquired from phantom. The established prescription dose was 45 Gy in 25 fractions of 1.8Gy/day. Results: For the planning target volume (PTV) coverage, 3D-CRT techniques (FILTER and field-in-field – FIF) showed inferior coverage compared to IMRT and VMAT plans. The 3D-CRT-FIF plan, on the other hand, shows greater homogeneity when compared to 3D-CRT-FILTER. For the contralateral lung, the 3D-CRT plans (FIF, FILTER) have better restrictions when compared with the other plans. On cardiac exposure, the 3D-CRT (FIF, FILTER) plans showed greater benefits when compared with IMRT, VMAT and Modified VMAT techniques. Conclusion: Conventional 3D-CRT techniques (FIF, FILTER) showed lower doses in organs at risk. However, IMRT and VMAT techniques obtained better homogeneity and conformity of the dose delivered to the PTV when compared to conventional techniques.Introducción: La radioterapia se utiliza en el tratamiento del cáncer de mama. En la planificación de la radioterapia, existen formas de desarrollar el plan de tratamiento, como la radioterapia conformacional 3D (3D-CRT), la radioterapia de intensidad modulada (IMRT) y la arcoterapia volumétrica modulada (VMAT). Objetivo: Comparar las dosis en órganos de riesgo y en el volumen blanco de tratamiento con diferentes técnicas de planificación: 3D-CRT, IMRT, VMAT y VMAT modificada para el tratamiento del cáncer de mama en un fantoma antropomórfico. Método: El plan de tratamiento se realizó en el sistema Eclipse™ v.15.6 de Varian a partir de imágenes de TC adquiridas del fantoma. La dosis de prescripción establecida fue de 45 Gy en 25 fracciones de 1,8Gy/día. Resultados: En cuanto a la cobertura del volumen blanco de planificación (VBP), las técnicas 3D-CRT (filtro - FILTRO y field-in-field – FIF) demostraron una cobertura inferior en comparación con los planes IMRT y VMAT. El plan 3D-RCT-FIF mostró mayor homogeneidad en comparación con el 3D-RCT-FILTRO. Para el pulmón contralateral, los planes 3D-CRT (FIF, FILTER) obtuvieron mejores restricciones en comparación con los otros planes. En la exposición cardiaca, los planes 3D-CRT (FIF, FILTER) mostraron mayores beneficios en comparación con las técnicas IMRT, VMAT y VMAT modificada. Conclusión: Las técnicas convencionales de 3D-CRT (FIF, FILTER) mostraron dosis más bajas en los órganos de riesgo. Sin embargo, las técnicas IMRT y VMAT obtuvieron una mejor homogeneidad y conformidad de la dosis distribuida en el VBP en comparación con las técnicas convencionales.Introdução: A radioterapia é utilizada no tratamento de câncer de mama. No planejamento radioterápico, há formas de desenvolver o plano de tratamento, como a radioterapia 3D conformacional (3D-CRT), a radioterapia de intensidade modulada (IMRT) e a arcoterapia volumétrica modulada (VMAT). Objetivo: Comparar as doses nos órgãos de risco e no volume-alvo de tratamento com as diferentes técnicas de planejamento: 3D-CRT, IMRT, VMAT e VMAT modificada para o tratamento do câncer de mama em um phantom antropomórfico. Método: O plano de tratamento foi realizado no sistema Eclipse™ v.15.6 da Varian a partir de imagens de tomografia computadorizada adquiridas de phantom. A dose de prescrição estabelecida foi de 45 Gy em 25 frações de 1,8 Gy/dia. Resultados: Sobre a cobertura do volume do alvo planejado (PTV), as técnicas 3D-CRT (FILTRO e field-in-field – FIF) demonstram cobertura inferior comparada aos planos de IMRT e VMAT. Já o plano 3D-CRT-FIF apresenta maior homogeneidade comparado ao 3D-CRT-FILTRO. Para o pulmão contralateral, os planos de 3D-CRT (FIF, FILTRO) obtiveram restrições melhores em relação aos demais planos. Sobre a exposição cardíaca, os planos 3D-CRT (FIF, FILTRO) apresentaram maiores benefícios do que as técnicas IMRT, VMAT e VMAT modificada. Conclusão: As técnicas convencionais 3D-CRT (FIF, FILTRO) apresentaram menores doses nos órgãos de risco. Contudo, as técnicas IMRT e VMAT obtiveram melhor homogeneidade e conformidade da dose distribuída no PTV ao comparar as técnicas convencionais.INCA2023-07-13info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigos, Avaliado pelos paresapplication/pdfapplication/pdfapplication/pdftext/htmlhttps://rbc.inca.gov.br/index.php/revista/article/view/402010.32635/2176-9745.RBC.2023v69n3.4020Revista Brasileira de Cancerologia; Vol. 69 No. 3 (2023): July/Aug./Sept.; e-074020Revista Brasileira de Cancerologia; Vol. 69 Núm. 3 (2023): jul./ago./sept.; e-074020Revista Brasileira de Cancerologia; v. 69 n. 3 (2023): jul./ago./set.; e-0740202176-9745reponame:Revista Brasileira de Cancerologia (Online)instname:Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)instacron:INCAporengspahttps://rbc.inca.gov.br/index.php/revista/article/view/4020/3018https://rbc.inca.gov.br/index.php/revista/article/view/4020/3319https://rbc.inca.gov.br/index.php/revista/article/view/4020/3214https://rbc.inca.gov.br/index.php/revista/article/view/4020/3028Copyright (c) 2023 Revista Brasileira de Cancerologiahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessPrandi, Tatiane Mayla DomingosZaias, Herofen Silva , Charlene daMüller , Juliana dos SantosBlasius, Larissa Palhano da Silva Dorow , Patrícia Fernanda2024-01-10T14:20:15Zoai:rbc.inca.gov.br:article/4020Revistahttps://rbc.inca.gov.br/index.php/revistaPUBhttps://rbc.inca.gov.br/index.php/revista/oairbc@inca.gov.br0034-71162176-9745opendoar:2024-01-10T14:20:15Revista Brasileira de Cancerologia (Online) - Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)false |
dc.title.none.fl_str_mv |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer Comparación Dosimétrica entre Técnicas de Planificación de Radioterapia para el Cáncer de Mama Izquierdo Comparação Dosimétrica entre Técnicas de Planejamento de Radioterapia para Câncer de Mama Esquerda |
title |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
spellingShingle |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer Prandi, Tatiane Mayla Domingos radioterapia conformacional radioterapia de intensidade modulada neoplasias da mama doses de radiação radiotherapy, conformal radiotherapy, intensity-modulated breast neoplasms radiation dosage radioterapia conformacional radioterapia de intensidad modulada neoplasias de la mama dosis de radiación Prandi, Tatiane Mayla Domingos radioterapia conformacional radioterapia de intensidade modulada neoplasias da mama doses de radiação radiotherapy, conformal radiotherapy, intensity-modulated breast neoplasms radiation dosage radioterapia conformacional radioterapia de intensidad modulada neoplasias de la mama dosis de radiación |
title_short |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
title_full |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
title_fullStr |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
title_full_unstemmed |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
title_sort |
Dosimetry Comparison of Radiotherapy Planning Techniques for Left Breast Cancer |
author |
Prandi, Tatiane Mayla Domingos |
author_facet |
Prandi, Tatiane Mayla Domingos Prandi, Tatiane Mayla Domingos Zaias, Herofen Silva , Charlene da Müller , Juliana dos Santos Blasius, Larissa Palhano da Silva Dorow , Patrícia Fernanda Zaias, Herofen Silva , Charlene da Müller , Juliana dos Santos Blasius, Larissa Palhano da Silva Dorow , Patrícia Fernanda |
author_role |
author |
author2 |
Zaias, Herofen Silva , Charlene da Müller , Juliana dos Santos Blasius, Larissa Palhano da Silva Dorow , Patrícia Fernanda |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Prandi, Tatiane Mayla Domingos Zaias, Herofen Silva , Charlene da Müller , Juliana dos Santos Blasius, Larissa Palhano da Silva Dorow , Patrícia Fernanda |
dc.subject.por.fl_str_mv |
radioterapia conformacional radioterapia de intensidade modulada neoplasias da mama doses de radiação radiotherapy, conformal radiotherapy, intensity-modulated breast neoplasms radiation dosage radioterapia conformacional radioterapia de intensidad modulada neoplasias de la mama dosis de radiación |
topic |
radioterapia conformacional radioterapia de intensidade modulada neoplasias da mama doses de radiação radiotherapy, conformal radiotherapy, intensity-modulated breast neoplasms radiation dosage radioterapia conformacional radioterapia de intensidad modulada neoplasias de la mama dosis de radiación |
description |
Introduction: Radiotherapy is utilized to treat breast cancer. For radiotherapy planning, there are several ways to develop the treatment plan, such as 3D conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Objective: To compare the doses to risk organs and treatment target volume with different planning techniques, 3D-CRT, IMRT, VMAT and modified VMAT for the treatment of breast cancer in an anthropomorphic phantom. Method: The treatment plan was performed in the Eclipse™ v.15.6 system by Varian from CT images acquired from phantom. The established prescription dose was 45 Gy in 25 fractions of 1.8Gy/day. Results: For the planning target volume (PTV) coverage, 3D-CRT techniques (FILTER and field-in-field – FIF) showed inferior coverage compared to IMRT and VMAT plans. The 3D-CRT-FIF plan, on the other hand, shows greater homogeneity when compared to 3D-CRT-FILTER. For the contralateral lung, the 3D-CRT plans (FIF, FILTER) have better restrictions when compared with the other plans. On cardiac exposure, the 3D-CRT (FIF, FILTER) plans showed greater benefits when compared with IMRT, VMAT and Modified VMAT techniques. Conclusion: Conventional 3D-CRT techniques (FIF, FILTER) showed lower doses in organs at risk. However, IMRT and VMAT techniques obtained better homogeneity and conformity of the dose delivered to the PTV when compared to conventional techniques. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-07-13 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artigos, Avaliado pelos pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://rbc.inca.gov.br/index.php/revista/article/view/4020 10.32635/2176-9745.RBC.2023v69n3.4020 |
url |
https://rbc.inca.gov.br/index.php/revista/article/view/4020 |
identifier_str_mv |
10.32635/2176-9745.RBC.2023v69n3.4020 |
dc.language.iso.fl_str_mv |
por eng spa |
language |
por eng spa |
dc.relation.none.fl_str_mv |
https://rbc.inca.gov.br/index.php/revista/article/view/4020/3018 https://rbc.inca.gov.br/index.php/revista/article/view/4020/3319 https://rbc.inca.gov.br/index.php/revista/article/view/4020/3214 https://rbc.inca.gov.br/index.php/revista/article/view/4020/3028 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2023 Revista Brasileira de Cancerologia https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2023 Revista Brasileira de Cancerologia https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf text/html |
dc.publisher.none.fl_str_mv |
INCA |
publisher.none.fl_str_mv |
INCA |
dc.source.none.fl_str_mv |
Revista Brasileira de Cancerologia; Vol. 69 No. 3 (2023): July/Aug./Sept.; e-074020 Revista Brasileira de Cancerologia; Vol. 69 Núm. 3 (2023): jul./ago./sept.; e-074020 Revista Brasileira de Cancerologia; v. 69 n. 3 (2023): jul./ago./set.; e-074020 2176-9745 reponame:Revista Brasileira de Cancerologia (Online) instname:Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA) instacron:INCA |
instname_str |
Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA) |
instacron_str |
INCA |
institution |
INCA |
reponame_str |
Revista Brasileira de Cancerologia (Online) |
collection |
Revista Brasileira de Cancerologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Cancerologia (Online) - Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA) |
repository.mail.fl_str_mv |
rbc@inca.gov.br |
_version_ |
1822182076546285568 |
dc.identifier.doi.none.fl_str_mv |
10.32635/2176-9745.RBC.2023v69n3.4020 |