Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma

Detalhes bibliográficos
Autor(a) principal: Costa, Marly G.F.
Data de Publicação: 2001
Outros Autores: Costa Filho, Cícero F.F., Moura Jr, Lincoln de Assis
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Brasileira de Cancerologia (Online)
Texto Completo: https://rbc.inca.gov.br/index.php/revista/article/view/2395
Resumo: Mammography has proven to be quite sensitive in detecting breast lesions, but frequently it cannot be used to accurately differentiate benign from malignant lesions. Many breast cancer experts believe that a better diagnostic imaging tool is needed, given that an estimated 700,000 breast biopsies are done every year, with only 1 out of 4 finding cancer. Many other imaging techniques have been studied. The scintimammography using Technetium-99m MIBI is a technique that has been studied over the last few years. The results obtained with these studies suggest that the scintimammography is a promising tool for diagnosing cancer. In this article we describe the technical aspects of scintimammography as proposed by Khalkhali (11) and present the results of several studies published about this new non-invasive test.
id INCA-1_e50c8102ae2ff5c7f4e0eb4b679a6385
oai_identifier_str oai:rbc.inca.gov.br:article/2395
network_acronym_str INCA-1
network_name_str Revista Brasileira de Cancerologia (Online)
repository_id_str
spelling Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast CarcinomaRevisão Bibliográfica Sobre o Uso da Cintilografia Mamária com Metoxi-Isobutilisonitrila - Tecnécio99m (MIBI-TC99M) no Diagnóstico Diferencial de Câncer de MamaCintilografia mamáriaNeoplasias mamáriasDiagnóstico por imagemMIBI-99mTcScintimammographyBreast neoplasmsImaging diagnosisTc-99m MIBIMammography has proven to be quite sensitive in detecting breast lesions, but frequently it cannot be used to accurately differentiate benign from malignant lesions. Many breast cancer experts believe that a better diagnostic imaging tool is needed, given that an estimated 700,000 breast biopsies are done every year, with only 1 out of 4 finding cancer. Many other imaging techniques have been studied. The scintimammography using Technetium-99m MIBI is a technique that has been studied over the last few years. The results obtained with these studies suggest that the scintimammography is a promising tool for diagnosing cancer. In this article we describe the technical aspects of scintimammography as proposed by Khalkhali (11) and present the results of several studies published about this new non-invasive test.A mamografia por Raios X tem apresentado alta sensibilidade na detecção de lesões de mama, porém a mesma tem se mostrado limitada na tarefa de diagnóstico diferencial. Muitos especialistas em câncer de mama crêem na necessidade de uma ferramenta de diagnóstico por imagem mais específica, uma vez que, da estimativa de 700.000 biópsias de mama feitas anualmente nos Estados Unidos, somente 1 em 4 apresenta achado de câncer. Outras técnicas de imagens estão sendo pesquisadas e, pelos resultados apresentados, poderão, em breve, assumir papel importante na detecção de lesões de mama em pacientes assintomáticos. Dentre essas novas técnicas destacamos a cintilografia mamária marcada com MIBI-99mTc. Neste trabalho, são descritos os aspectos técnicos desse novo exame, realizado segundo a técnica proposta por Khalkhali11 e são apresentados os resultados de vários estudos publicados nos últimos anos.INCA2001-03-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigos, Avaliado pelos paresapplication/pdfhttps://rbc.inca.gov.br/index.php/revista/article/view/239510.32635/2176-9745.RBC.2001v47n1.2395Revista Brasileira de Cancerologia; Vol. 47 No. 1 (2001): Jan./Feb./Mar.; 33-42Revista Brasileira de Cancerologia; Vol. 47 Núm. 1 (2001): ene./feb./mar.; 33-42Revista Brasileira de Cancerologia; v. 47 n. 1 (2001): jan./fev./mar.; 33-422176-9745reponame:Revista Brasileira de Cancerologia (Online)instname:Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)instacron:INCAporhttps://rbc.inca.gov.br/index.php/revista/article/view/2395/1478Costa, Marly G.F. Costa Filho, Cícero F.F. Moura Jr, Lincoln de Assis info:eu-repo/semantics/openAccess2021-11-29T20:42:37Zoai:rbc.inca.gov.br:article/2395Revistahttps://rbc.inca.gov.br/index.php/revistaPUBhttps://rbc.inca.gov.br/index.php/revista/oairbc@inca.gov.br0034-71162176-9745opendoar:2021-11-29T20:42:37Revista Brasileira de Cancerologia (Online) - Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)false
dc.title.none.fl_str_mv Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
Revisão Bibliográfica Sobre o Uso da Cintilografia Mamária com Metoxi-Isobutilisonitrila - Tecnécio99m (MIBI-TC99M) no Diagnóstico Diferencial de Câncer de Mama
title Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
spellingShingle Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
Costa, Marly G.F.
Cintilografia mamária
Neoplasias mamárias
Diagnóstico por imagem
MIBI-99mTc
Scintimammography
Breast neoplasms
Imaging diagnosis
Tc-99m MIBI
title_short Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
title_full Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
title_fullStr Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
title_full_unstemmed Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
title_sort Literature Review of the Use of Scintimammography with Technetium-99m Methoxyisobutylisonitrile (99mTc-MIBI) for the Differential Diagnosis of Breast Carcinoma
author Costa, Marly G.F.
author_facet Costa, Marly G.F.
Costa Filho, Cícero F.F.
Moura Jr, Lincoln de Assis
author_role author
author2 Costa Filho, Cícero F.F.
Moura Jr, Lincoln de Assis
author2_role author
author
dc.contributor.author.fl_str_mv Costa, Marly G.F.
Costa Filho, Cícero F.F.
Moura Jr, Lincoln de Assis
dc.subject.por.fl_str_mv Cintilografia mamária
Neoplasias mamárias
Diagnóstico por imagem
MIBI-99mTc
Scintimammography
Breast neoplasms
Imaging diagnosis
Tc-99m MIBI
topic Cintilografia mamária
Neoplasias mamárias
Diagnóstico por imagem
MIBI-99mTc
Scintimammography
Breast neoplasms
Imaging diagnosis
Tc-99m MIBI
description Mammography has proven to be quite sensitive in detecting breast lesions, but frequently it cannot be used to accurately differentiate benign from malignant lesions. Many breast cancer experts believe that a better diagnostic imaging tool is needed, given that an estimated 700,000 breast biopsies are done every year, with only 1 out of 4 finding cancer. Many other imaging techniques have been studied. The scintimammography using Technetium-99m MIBI is a technique that has been studied over the last few years. The results obtained with these studies suggest that the scintimammography is a promising tool for diagnosing cancer. In this article we describe the technical aspects of scintimammography as proposed by Khalkhali (11) and present the results of several studies published about this new non-invasive test.
publishDate 2001
dc.date.none.fl_str_mv 2001-03-30
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artigos, Avaliado pelos pares
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rbc.inca.gov.br/index.php/revista/article/view/2395
10.32635/2176-9745.RBC.2001v47n1.2395
url https://rbc.inca.gov.br/index.php/revista/article/view/2395
identifier_str_mv 10.32635/2176-9745.RBC.2001v47n1.2395
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://rbc.inca.gov.br/index.php/revista/article/view/2395/1478
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv INCA
publisher.none.fl_str_mv INCA
dc.source.none.fl_str_mv Revista Brasileira de Cancerologia; Vol. 47 No. 1 (2001): Jan./Feb./Mar.; 33-42
Revista Brasileira de Cancerologia; Vol. 47 Núm. 1 (2001): ene./feb./mar.; 33-42
Revista Brasileira de Cancerologia; v. 47 n. 1 (2001): jan./fev./mar.; 33-42
2176-9745
reponame:Revista Brasileira de Cancerologia (Online)
instname:Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)
instacron:INCA
instname_str Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)
instacron_str INCA
institution INCA
reponame_str Revista Brasileira de Cancerologia (Online)
collection Revista Brasileira de Cancerologia (Online)
repository.name.fl_str_mv Revista Brasileira de Cancerologia (Online) - Instituto Nacional de Câncer José Alencar Gomes da Silva (INCA)
repository.mail.fl_str_mv rbc@inca.gov.br
_version_ 1797042250160537600