Resistence of compression between a direct composite resin and two ceromers
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265 |
Resumo: | That review assessed the resistance of the fracture at the two laboratorial resins that if they find in the market, the one Artglass® and the other one Targis® as a bevy compared the direct composite resin TPH®. Five bodies as of he samples as of each resin the one being assayed were used. With the matrix of stainless steel assistance along form of a cone segment, along measurements internal as of 8 mm in diameter at the entry level 9 mm at the portion better and 4 mm as of height, have been made the bodies of proving. The samples have been maintained well into water deionizer by 72 hours and submitted to a bulk axial action from a butt as of border rounded in shape as of 2 mm bore, adapted to an appliance as of test across the board EMIC 500. The velocity was 0,05 mm/min, along a cell as of capacitance as of bulk of the 200 kgf. The bulk and the point of fracture have been registered at the machine. The averages have been calculated well into kgf, being the one Artglass® introducing Targis T TPH Tp = 98,26. The data have been submitted at the statistic analysis. Observed in case that than it is to the resin TPH got considerably under age endurance at the compression while Targis and Artiglass did not they presented difference statistics considerably between they self; the contents of inorganic load influences positively into a resistance of compression. UNITERMS: composite resin; laboratorial resin; resistance of compression. |
id |
PUC_RS-22_4383efbb0c821bc4859d2d619567e25b |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/1265 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Resistence of compression between a direct composite resin and two ceromersResistência à compressão entre uma resina composta direta e dois cerômerosThat review assessed the resistance of the fracture at the two laboratorial resins that if they find in the market, the one Artglass® and the other one Targis® as a bevy compared the direct composite resin TPH®. Five bodies as of he samples as of each resin the one being assayed were used. With the matrix of stainless steel assistance along form of a cone segment, along measurements internal as of 8 mm in diameter at the entry level 9 mm at the portion better and 4 mm as of height, have been made the bodies of proving. The samples have been maintained well into water deionizer by 72 hours and submitted to a bulk axial action from a butt as of border rounded in shape as of 2 mm bore, adapted to an appliance as of test across the board EMIC 500. The velocity was 0,05 mm/min, along a cell as of capacitance as of bulk of the 200 kgf. The bulk and the point of fracture have been registered at the machine. The averages have been calculated well into kgf, being the one Artglass® introducing Targis T TPH Tp = 98,26. The data have been submitted at the statistic analysis. Observed in case that than it is to the resin TPH got considerably under age endurance at the compression while Targis and Artiglass did not they presented difference statistics considerably between they self; the contents of inorganic load influences positively into a resistance of compression. UNITERMS: composite resin; laboratorial resin; resistance of compression.Esse estudo avaliou a resistência à fratura de duas resinas laboratoriais que se encontram no mercado, a Artglass® e a Targis® e como grupo comparador, a resina composta direta TPH®. Foram utilizados cinco corpos de prova de cada resina a ser testada. Com o auxílio de matrizes em aço inoxidável com forma de um cone segmentado, com medidas internas de 8,0 mm de diâmetro na base, 9,0 mm na porção superior e 4,0 mm de altura, foram confeccionados os corpos de prova. As amostras foram mantidas em água destilada por 72 horas e submetidas a uma carga axial por ação de uma ponta de extremidade arredondada de 2 mm diâmetro, adaptada a uma máquina de teste universal EMIC 500. A velocidade foi de 0,5 mm/min, com uma célula de capacidade de carga de 200 kgf. A carga e o ponto de fratura foram registrados na máquina. As médias foram calculadas em kgf, sendo o Artglass® apresentando A = 223,46; Targis® T = 204,13; TPH® Tp = 98,26. Os dados foram submetidos à análise estatística. Observou-se que a resina TPH obteve significativamente menor resistência à compressão enquanto Targis e Artiglass não apresentaram diferença estaticamente significativamente entre si; o conteúdo de carga inorgânica influencia positivamente na resistência à compressão. UNITERMOS: resina composta; resina laboratorial; resistência à compressão.EDIPUCRS - Editora Universitária da PUCRS2007-07-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265Revista Odonto Ciência; Vol. 22 No. 56 (2007); 138 - 142Revista Odonto Ciência; v. 22 n. 56 (2007); 138 - 1421980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265/990Gouvêa, Cresus Vinícius Depes deCouto, Cíntia Fernandes doMoraes, Camila MartinsBarros, Renata Nunesinfo:eu-repo/semantics/openAccess2013-11-18T11:15:02Zoai:ojs.revistaseletronicas.pucrs.br:article/1265Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T11:15:02Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Resistence of compression between a direct composite resin and two ceromers Resistência à compressão entre uma resina composta direta e dois cerômeros |
title |
Resistence of compression between a direct composite resin and two ceromers |
spellingShingle |
Resistence of compression between a direct composite resin and two ceromers Gouvêa, Cresus Vinícius Depes de |
title_short |
Resistence of compression between a direct composite resin and two ceromers |
title_full |
Resistence of compression between a direct composite resin and two ceromers |
title_fullStr |
Resistence of compression between a direct composite resin and two ceromers |
title_full_unstemmed |
Resistence of compression between a direct composite resin and two ceromers |
title_sort |
Resistence of compression between a direct composite resin and two ceromers |
author |
Gouvêa, Cresus Vinícius Depes de |
author_facet |
Gouvêa, Cresus Vinícius Depes de Couto, Cíntia Fernandes do Moraes, Camila Martins Barros, Renata Nunes |
author_role |
author |
author2 |
Couto, Cíntia Fernandes do Moraes, Camila Martins Barros, Renata Nunes |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Gouvêa, Cresus Vinícius Depes de Couto, Cíntia Fernandes do Moraes, Camila Martins Barros, Renata Nunes |
description |
That review assessed the resistance of the fracture at the two laboratorial resins that if they find in the market, the one Artglass® and the other one Targis® as a bevy compared the direct composite resin TPH®. Five bodies as of he samples as of each resin the one being assayed were used. With the matrix of stainless steel assistance along form of a cone segment, along measurements internal as of 8 mm in diameter at the entry level 9 mm at the portion better and 4 mm as of height, have been made the bodies of proving. The samples have been maintained well into water deionizer by 72 hours and submitted to a bulk axial action from a butt as of border rounded in shape as of 2 mm bore, adapted to an appliance as of test across the board EMIC 500. The velocity was 0,05 mm/min, along a cell as of capacitance as of bulk of the 200 kgf. The bulk and the point of fracture have been registered at the machine. The averages have been calculated well into kgf, being the one Artglass® introducing Targis T TPH Tp = 98,26. The data have been submitted at the statistic analysis. Observed in case that than it is to the resin TPH got considerably under age endurance at the compression while Targis and Artiglass did not they presented difference statistics considerably between they self; the contents of inorganic load influences positively into a resistance of compression. UNITERMS: composite resin; laboratorial resin; resistance of compression. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-07-03 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/1265/990 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 22 No. 56 (2007); 138 - 142 Revista Odonto Ciência; v. 22 n. 56 (2007); 138 - 142 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820873734324224 |