Electroanalytical determination of codeine in pharmaceutical preparations
Autor(a) principal: | |
---|---|
Data de Publicação: | 2002 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.22/2960 |
Resumo: | A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%. |
id |
RCAP_2d33553c3ed110ed4dce9d5ca68e6d03 |
---|---|
oai_identifier_str |
oai:recipp.ipp.pt:10400.22/2960 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Electroanalytical determination of codeine in pharmaceutical preparationsCodeineSquare wave voltammetryFlow injection analysis with electrochemical detectionAcetaminophenGuaiacolParabensEphedrineAcetylsalicylic acidCaffeineA square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.Taylor & FrancisRepositório Científico do Instituto Politécnico do PortoGarrido, JorgeDelerue-Matos, CristinaBorges, FernandaMacedo, Tice R. A.Oliveira-Brett, A. M.2013-11-26T15:52:06Z20022002-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/2960eng10.1081/AL-120016539info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-13T12:42:35Zoai:recipp.ipp.pt:10400.22/2960Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:23:58.808140Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Electroanalytical determination of codeine in pharmaceutical preparations |
title |
Electroanalytical determination of codeine in pharmaceutical preparations |
spellingShingle |
Electroanalytical determination of codeine in pharmaceutical preparations Garrido, Jorge Codeine Square wave voltammetry Flow injection analysis with electrochemical detection Acetaminophen Guaiacol Parabens Ephedrine Acetylsalicylic acid Caffeine |
title_short |
Electroanalytical determination of codeine in pharmaceutical preparations |
title_full |
Electroanalytical determination of codeine in pharmaceutical preparations |
title_fullStr |
Electroanalytical determination of codeine in pharmaceutical preparations |
title_full_unstemmed |
Electroanalytical determination of codeine in pharmaceutical preparations |
title_sort |
Electroanalytical determination of codeine in pharmaceutical preparations |
author |
Garrido, Jorge |
author_facet |
Garrido, Jorge Delerue-Matos, Cristina Borges, Fernanda Macedo, Tice R. A. Oliveira-Brett, A. M. |
author_role |
author |
author2 |
Delerue-Matos, Cristina Borges, Fernanda Macedo, Tice R. A. Oliveira-Brett, A. M. |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Repositório Científico do Instituto Politécnico do Porto |
dc.contributor.author.fl_str_mv |
Garrido, Jorge Delerue-Matos, Cristina Borges, Fernanda Macedo, Tice R. A. Oliveira-Brett, A. M. |
dc.subject.por.fl_str_mv |
Codeine Square wave voltammetry Flow injection analysis with electrochemical detection Acetaminophen Guaiacol Parabens Ephedrine Acetylsalicylic acid Caffeine |
topic |
Codeine Square wave voltammetry Flow injection analysis with electrochemical detection Acetaminophen Guaiacol Parabens Ephedrine Acetylsalicylic acid Caffeine |
description |
A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%. |
publishDate |
2002 |
dc.date.none.fl_str_mv |
2002 2002-01-01T00:00:00Z 2013-11-26T15:52:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.22/2960 |
url |
http://hdl.handle.net/10400.22/2960 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1081/AL-120016539 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Taylor & Francis |
publisher.none.fl_str_mv |
Taylor & Francis |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799131334709346304 |