Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions

Detalhes bibliográficos
Autor(a) principal: Sousa, C. C. S.
Data de Publicação: 2015
Outros Autores: Botelho, João, Grosso, Filipa, Silva, Liliana, Lopes, João, Peixe, Luísa
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/35242
Resumo: MALDI-TOF MS (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry) is now in the forefront for routine bacterial species identification methodologies, being its value for clonality assessment controversial. In this work we evaluated the potential of MALDI-TOF MS for assisting infection control by depicting Acinetobacter baumannii clones. Mass spectra of 58 A. baumannii clinical isolates belonging to the worldwide spread lineages (ST98, ST103, ST208 and ST218) isolated in our country, were obtained and analysed with several chemometric tools (pseudo gel views, peakfind function and partial least squares discriminant analysis). The clonal lineages were obtained using the Oxford scheme, belonging ST98, ST208 and ST218 to the international clone II and ST103 to an epidemic clonal lineage (SG5). Additionally, mass spectra of a highly diverse international collection of 38 isolates belonging to 22 STs were obtained for further comparisons. Pseudo gel views and direct peak pattern analysis didnt allow the discrimination of A. baumannii isolates belonging to ST98, ST103, ST208 or ST218. Moreover, a partial least square discriminant analysis of the mass spectra considering two spectral ranges (2-20kDa and 4-10kDa) revealed a poor degree of discrimination with only 64.6% and 65.8% of correct ST assignments, respectively. Also, mass spectra of the international isolates (n=38, 22STs) revealed a very congruent peak pattern among them as well as among the four lineages included in this work. Despite the increasing interest of MALDI-TOF MS for bacterial typing at different taxonomical levels, we demonstrated, using routine experimental conditions, the unsuitability of this methodology for A. baumannii clonal discrimination.
id RCAP_4b606f6e1a13f8155e76301924b28770
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/35242
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditionsAcinetobacter baumanniitypingMALDI-TOF MSsubspecieschemometricssequence typeCiências Médicas::Biotecnologia MédicaScience & TechnologyMALDI-TOF MS (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry) is now in the forefront for routine bacterial species identification methodologies, being its value for clonality assessment controversial. In this work we evaluated the potential of MALDI-TOF MS for assisting infection control by depicting Acinetobacter baumannii clones. Mass spectra of 58 A. baumannii clinical isolates belonging to the worldwide spread lineages (ST98, ST103, ST208 and ST218) isolated in our country, were obtained and analysed with several chemometric tools (pseudo gel views, peakfind function and partial least squares discriminant analysis). The clonal lineages were obtained using the Oxford scheme, belonging ST98, ST208 and ST218 to the international clone II and ST103 to an epidemic clonal lineage (SG5). Additionally, mass spectra of a highly diverse international collection of 38 isolates belonging to 22 STs were obtained for further comparisons. Pseudo gel views and direct peak pattern analysis didnt allow the discrimination of A. baumannii isolates belonging to ST98, ST103, ST208 or ST218. Moreover, a partial least square discriminant analysis of the mass spectra considering two spectral ranges (2-20kDa and 4-10kDa) revealed a poor degree of discrimination with only 64.6% and 65.8% of correct ST assignments, respectively. Also, mass spectra of the international isolates (n=38, 22STs) revealed a very congruent peak pattern among them as well as among the four lineages included in this work. Despite the increasing interest of MALDI-TOF MS for bacterial typing at different taxonomical levels, we demonstrated, using routine experimental conditions, the unsuitability of this methodology for A. baumannii clonal discrimination.This work was funded by FEDER funds through the Operational Programme for Competitiveness Factors - COMPETE and by National Funds through FCT - Foundation for Science and Technology under the project UID/MULTI/04378/2013. LS was supported by doctoral grant (SFRH/BD/88028/2012) and FG by a post doc grant (SFRH/BPD/95556/2013) from Fundacao para a Ciencia e a Tecnologia. CS was funded by a CIENCIA2008 contract from FCT.Frontiers MediaUniversidade do MinhoSousa, C. C. S.Botelho, JoãoGrosso, FilipaSilva, LilianaLopes, JoãoPeixe, Luísa2015-052015-05-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/35242engSousa, C. C. S.; Botelho, J.; Grosso, F.; Silva, L.; Lopes, J.; Peixe, L., Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions. Frontiers in Microbiology, 6(481), 20151664-302X10.3389/fmicb.2015.00481http://journal.frontiersin.org/article/10.3389/fmicb.2015.00481/abstractinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:10:27Zoai:repositorium.sdum.uminho.pt:1822/35242Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T19:02:05.342355Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
title Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
spellingShingle Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
Sousa, C. C. S.
Acinetobacter baumannii
typing
MALDI-TOF MS
subspecies
chemometrics
sequence type
Ciências Médicas::Biotecnologia Médica
Science & Technology
title_short Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
title_full Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
title_fullStr Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
title_full_unstemmed Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
title_sort Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions
author Sousa, C. C. S.
author_facet Sousa, C. C. S.
Botelho, João
Grosso, Filipa
Silva, Liliana
Lopes, João
Peixe, Luísa
author_role author
author2 Botelho, João
Grosso, Filipa
Silva, Liliana
Lopes, João
Peixe, Luísa
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Sousa, C. C. S.
Botelho, João
Grosso, Filipa
Silva, Liliana
Lopes, João
Peixe, Luísa
dc.subject.por.fl_str_mv Acinetobacter baumannii
typing
MALDI-TOF MS
subspecies
chemometrics
sequence type
Ciências Médicas::Biotecnologia Médica
Science & Technology
topic Acinetobacter baumannii
typing
MALDI-TOF MS
subspecies
chemometrics
sequence type
Ciências Médicas::Biotecnologia Médica
Science & Technology
description MALDI-TOF MS (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry) is now in the forefront for routine bacterial species identification methodologies, being its value for clonality assessment controversial. In this work we evaluated the potential of MALDI-TOF MS for assisting infection control by depicting Acinetobacter baumannii clones. Mass spectra of 58 A. baumannii clinical isolates belonging to the worldwide spread lineages (ST98, ST103, ST208 and ST218) isolated in our country, were obtained and analysed with several chemometric tools (pseudo gel views, peakfind function and partial least squares discriminant analysis). The clonal lineages were obtained using the Oxford scheme, belonging ST98, ST208 and ST218 to the international clone II and ST103 to an epidemic clonal lineage (SG5). Additionally, mass spectra of a highly diverse international collection of 38 isolates belonging to 22 STs were obtained for further comparisons. Pseudo gel views and direct peak pattern analysis didnt allow the discrimination of A. baumannii isolates belonging to ST98, ST103, ST208 or ST218. Moreover, a partial least square discriminant analysis of the mass spectra considering two spectral ranges (2-20kDa and 4-10kDa) revealed a poor degree of discrimination with only 64.6% and 65.8% of correct ST assignments, respectively. Also, mass spectra of the international isolates (n=38, 22STs) revealed a very congruent peak pattern among them as well as among the four lineages included in this work. Despite the increasing interest of MALDI-TOF MS for bacterial typing at different taxonomical levels, we demonstrated, using routine experimental conditions, the unsuitability of this methodology for A. baumannii clonal discrimination.
publishDate 2015
dc.date.none.fl_str_mv 2015-05
2015-05-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/35242
url http://hdl.handle.net/1822/35242
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Sousa, C. C. S.; Botelho, J.; Grosso, F.; Silva, L.; Lopes, J.; Peixe, L., Unsuitability of MALDI-TOF MS to discriminate Acinetobacter baumannii clones under our routine experimental conditions. Frontiers in Microbiology, 6(481), 2015
1664-302X
10.3389/fmicb.2015.00481
http://journal.frontiersin.org/article/10.3389/fmicb.2015.00481/abstract
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Frontiers Media
publisher.none.fl_str_mv Frontiers Media
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132421437784064